Space-charge-dominated mass spectrometry ion sources: Modeling and sensitivity.

M Busman1, J Sunner, C R Vogel.   

Abstract

The factors determining the sensitivity of space-charge-dominated (SCD) unipolar ion sources, such as electrospray (ESP) and corona atmospheric pressure ionization (API) have been studied theoretically. The most important parameters are the ion density and ion drift time in the vicinity of the sampling orifice. These are obtained by solving a system of differential equations, "the space-charge problem." For some simple geometries, analytical solutions are known. For a more realistic "needle-in-can" geometry, a solution to the space-charge problem was obtained using a finite-element method. The results illustrate some general characteristics of SCD ion sources. It is shown that for typical operating conditions the minimum voltage required to overcome the space-charge effect in corona API or ESP ion sources constitutes a dominant or significant fraction of total applied voltage. Further, the electric field and the ion density in the region of the ion-sampling orifice as well as the ion residence time in the source are determined mainly by the space charge. Finally, absolute sensitivities of corona API ion sources were calculated by using a geometry-independent treatment of space charge.

Entities:  

Year:  1991        PMID: 24242083     DOI: 10.1016/1044-0305(91)80055-C

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  1 in total

Review 1.  Electrospray ionization for mass spectrometry of large biomolecules.

Authors:  J B Fenn; M Mann; C K Meng; S F Wong; C M Whitehouse
Journal:  Science       Date:  1989-10-06       Impact factor: 47.728

  1 in total
  8 in total

1.  Factors influencing the analytical performance of an atmospheric sampling glow discharge ionization source as revealed via ionization dynamics modeling.

Authors:  Douglas E Goeringer
Journal:  J Am Soc Mass Spectrom       Date:  2003-11       Impact factor: 3.109

2.  Investigation of electrospray ionization and electrostatic focusing devices using a three-dimensional electrospray current density profiler.

Authors:  J Will Thompson; John W Eschelbach; Richard T Wilburn; James W Jorgenson
Journal:  J Am Soc Mass Spectrom       Date:  2005-03       Impact factor: 3.109

3.  Controlling gas-phase reactions for efficient charge reduction electrospray mass spectrometry of intact proteins.

Authors:  Brian L Frey; Yuan Lin; Michael S Westphall; Lloyd M Smith
Journal:  J Am Soc Mass Spectrom       Date:  2005-09-28       Impact factor: 3.109

4.  Ion transport by viscous gas flow through capillaries.

Authors:  B Lin; J Sunner
Journal:  J Am Soc Mass Spectrom       Date:  1994-10       Impact factor: 3.109

5.  Biases in ion transmission through an electrospray ionization-mass spectrometry capillary inlet.

Authors:  Jason S Page; Ioan Marginean; Erin S Baker; Ryan T Kelly; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2009-09-02       Impact factor: 3.109

6.  Ionization and transmission efficiency in an electrospray ionization-mass spectrometry interface.

Authors:  Jason S Page; Ryan T Kelly; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2007-06-02       Impact factor: 3.109

7.  Electrospray mass spectrometry of methanol and water solutions suppression of electric discharge with SF6 gas.

Authors:  M G Ikonomou; A T Blades; P Kebarle
Journal:  J Am Soc Mass Spectrom       Date:  1991-12       Impact factor: 3.109

Review 8.  Response in Ambient Low Temperature Plasma Ionization Compared to Electrospray and Atmospheric Pressure Chemical Ionization for Mass Spectrometry.

Authors:  Andreas Kiontke; Susan Billig; Claudia Birkemeyer
Journal:  Int J Anal Chem       Date:  2018-12-18       Impact factor: 1.885

  8 in total