Literature DB >> 24240882

Using a collagen matrix implant (Ologen) versus mitomycin-C as a wound healing modulator in trabeculectomy with the Ex-PRESS mini glaucoma device: a 12-month retrospective review.

Matthew S Johnson1, Steven R Sarkisian.   

Abstract

PURPOSE: To compare outcomes between patients undergoing trabeculectomy with an Ex-PRESS mini glaucoma device using mitomycin-C (MMC) to those undergoing the same procedure using a subconjunctival collagen matrix implant (Ologen).
MATERIALS AND METHODS: All patients underwent a trabeculectomy using an Ex-PRESS shunt. A total of 49 eyes of 37 patients received Ologen, and 50 eyes of 48 patients received MMC. Postoperative data were reviewed over 12 months. Outcomes included mean intraocular pressure (IOP), rate of success in achieving a target IOP (with and without antiglaucoma medications), number of medications used, and rates of complications/reoperations.
RESULTS: The mean preoperative IOP was 24.98 mm Hg for the MMC group, and 23.24 mm Hg for the Ologen group (P=0.3). At 12 months postoperatively, the mean IOP was 12.1 mm Hg for the MMC group, and 13.12 mm Hg for the Ologen group (P=0.34). At 12 months, the rate of achieving an IOP≤21 mm Hg off medications (unqualified success) was 84% for the MMC group, and 86% for the Ologen group. There was no statistically significant difference between either group for the rates of achieving a specified postoperative IOP either with (qualified success) or without medications. There was no statistically significant difference between the 2 groups in the mean number of postoperative medications required. Both groups had similar rates of complications, and 1 patient in the MMC group lost light perception after a suprachoroidal hemorrhage.
CONCLUSIONS: Our results suggest that ologen provides similar rates of surgical success as MMC for patients undergoing a filtering procedure using an Ex-PRESS mini glaucoma device.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24240882     DOI: 10.1097/IJG.0000000000000018

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  15 in total

Review 1.  Overview of cicatricial modulators in glaucoma fistulizing surgery.

Authors:  Camille Moura de Oliveira; Juliana de Lucena Martins Ferreira
Journal:  Int Ophthalmol       Date:  2020-06-05       Impact factor: 2.031

2.  Ex-PRESS outcomes using mitomycin-C, Ologen alone, Ologen with 5-fluorouracil.

Authors:  Shivali A Menda; Eugene A Lowry; Travis C Porco; Robert L Stamper; Michel R Rubin; Ying Han
Journal:  Int Ophthalmol       Date:  2014-06-12       Impact factor: 2.031

3.  Subconjunctival implantation of ologen Collagen Matrix to treat ocular hypotony after filtration glaucoma surgery.

Authors:  M Tanito; A Okada; Y Mori; I Sano; Y Ikeda; E Fujihara
Journal:  Eye (Lond)       Date:  2017-06-02       Impact factor: 3.775

4.  Trabeculectomy with ologen in secondary glaucomas following failed trabeculectomy with MMC: comparative study.

Authors:  H M A El-Saied; M A S E Abdelhakim
Journal:  Eye (Lond)       Date:  2016-06-03       Impact factor: 3.775

5.  Biodegradable PTLGA Terpolymers versus Collagen Implants Used as an Adjuvant in Trabeculectomy in Rabbit Eye.

Authors:  Weiran Niu; Guanglin Shen; Yuanzhi Yuan; Xiaoping Ma; Suming Li; Jingzhao Wang; Zhongyong Fan; Lan Liao
Journal:  J Ophthalmol       Date:  2015-11-30       Impact factor: 1.909

Review 6.  Device-modified trabeculectomy for glaucoma.

Authors:  Xue Wang; Rabeea Khan; Anne Coleman
Journal:  Cochrane Database Syst Rev       Date:  2015-12-01

7.  Biodegradable collagen matrix (Ologen™) implant and conjunctival autograft for scleral necrosis after pterygium excision: two case reports.

Authors:  Chan-Ho Cho; Sang-Bumm Lee
Journal:  BMC Ophthalmol       Date:  2015-10-24       Impact factor: 2.209

8.  Meta-analysis of randomized controlled trials comparing EX-PRESS implantation with trabeculectomy for open-angle glaucoma.

Authors:  Wei Wang; Xiulan Zhang
Journal:  PLoS One       Date:  2014-06-27       Impact factor: 3.240

Review 9.  Biodegradable Collagen Implants in Trabeculectomy.

Authors:  Parul Ichhpujani; Tanuj Dada; Shibal Bhartiya
Journal:  J Curr Glaucoma Pract       Date:  2015-01-15

Review 10.  Wound Healing Modulation in Glaucoma Filtration Surgery- Conventional Practices and New Perspectives: Antivascular Endothelial Growth Factor and Novel Agents (Part II).

Authors:  Jennifer C Fan Gaskin; Dan Q Nguyen; Ghee Soon Ang; Jeremy O'Connor; Jonathan G Crowston
Journal:  J Curr Glaucoma Pract       Date:  2014-06-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.