Literature DB >> 24240731

Left ventricular assist device management in the ICU.

Alexandra K Pratt1, Nimesh S Shah, Steven W Boyce.   

Abstract

OBJECTIVES: To review left ventricular assist device physiology, initial postoperative management, common complications, trouble shooting and management of hypotension, and other common ICU problems. DATA SOURCE: Narrative review of relevant medical literature. DATA SYNTHESIS: Left ventricular assist devices prolong the lives of patients with end-stage heart failure, and their use is increasing. Continuous-flow left ventricular assist devices have replaced first-generation pulsatile devices. These patients present unique management concerns. In the immediate postimplant period, care must be taken to support the unassisted right ventricle. Invasive monitors for blood pressure, pulmonary artery catheterization, and echocardiography are essential to optimize left ventricular assist device settings and cardiac performance. Anticoagulation is necessary to prevent devastating thrombotic and embolic complications, but bleeding is a major source of morbidity due to inherent bleeding diatheses and prescribed anticoagulants. Infection of the device can be life threatening, and all infections must be aggressively treated to avoid seeding the device. Patients are at risk of ventricular arrhythmias because of their underlying disease, as well as the placement and position of the inflow cannula. Aortic valve stenosis and insufficiency develop over time and can lead to thrombosis or heart failure. Cardiopulmonary resuscitation with chest compressions must be performed with care or not at all due to risk of dislodging the device.
CONCLUSION: Intensivists are increasingly likely to encounter patients requiring mechanical circulatory support with left ventricular assist devices at various points in the trajectory of their disease, from the immediate postimplant period to subsequent admissions for complications, and at end of life. A basic understanding of left ventricular assist device physiology is essential to the safe and effective care of these patients.

Entities:  

Mesh:

Year:  2014        PMID: 24240731     DOI: 10.1097/01.ccm.0000435675.91305.76

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  6 in total

Review 1.  Echocardiographic assessment for ventricular assist device placement.

Authors:  Antolin S Flores; Michael Essandoh; Gregory C Yerington; Amar M Bhatt; Manoj H Iyer; William Perez; Victor R Davila; Ravi S Tripathi; Katja Turner; Galina Dimitrova; Michael J Andritsos
Journal:  J Thorac Dis       Date:  2015-12       Impact factor: 2.895

Review 2.  [Recommendations for emergency management of patients with permanent mechanical circulatory support : Consensus statement of DGTHG, DIVI, DGIIN, DGAI, DGINA, DGfK and DGK].

Authors:  Kevin Pilarczyk; Udo Boeken; Andreas Beckmann; Andreas Markewitz; P Christian Schulze; Martin Pin; Ingo Gräff; Sebastian Schmidt; Birk Runge; Hans-Jörg Busch; Michael R Preusch; Nils Haake; Gereon Schälte; Jan Gummert; Guido Michels
Journal:  Anaesthesist       Date:  2020-04       Impact factor: 1.041

Review 3.  Ventricular assist devices and non-cardiac surgery.

Authors:  S Michael Roberts; David G Hovord; Ramesh Kodavatiganti; Subramanian Sathishkumar
Journal:  BMC Anesthesiol       Date:  2015-12-19       Impact factor: 2.217

4.  Circulating microRNAs and Outcome in Patients with Acute Heart Failure.

Authors:  Marie-France Seronde; Mélanie Vausort; Etienne Gayat; Emeline Goretti; Leong L Ng; Iain B Squire; Nicolas Vodovar; Malha Sadoune; Jane-Lise Samuel; Thomas Thum; Alain Cohen Solal; Said Laribi; Patrick Plaisance; Daniel R Wagner; Alexandre Mebazaa; Yvan Devaux
Journal:  PLoS One       Date:  2015-11-18       Impact factor: 3.240

Review 5.  Mechanical circulatory assist devices: a primer for critical care and emergency physicians.

Authors:  Ayan Sen; Joel S Larson; Kianoush B Kashani; Stacy L Libricz; Bhavesh M Patel; Pramod K Guru; Cory M Alwardt; Octavio Pajaro; J Christopher Farmer
Journal:  Crit Care       Date:  2016-06-25       Impact factor: 9.097

6.  Left Atrial Pressure Monitoring With an Implantable Wireless Pressure Sensor After Implantation of a Left Ventricular Assist Device.

Authors:  Laila Hubbert; Jacek Baranowski; Baz Delshad; Henrik Ahn
Journal:  ASAIO J       Date:  2017 Sep/Oct       Impact factor: 2.872

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.