Literature DB >> 24240721

Automatic tracking of aponeuroses and estimation of muscle thickness in ultrasonography: a feasibility study.

Shan Ling, Yongjin Zhou, Ye Chen, Yu-Qian Zhao, Lei Wang, Yong-Ping Zheng.   

Abstract

Muscle thickness measurement in ultrasonography was traditionally conducted by a trained operator, and the manual detecting process is time consuming and subjective. In this paper, we proposed an automatic tracking strategy to achieve the continuous and quantitative measurement for gastrocnemius muscle thickness in ultrasound images. The method involved three steps: tracking of seed points, contours extraction of aponeuroses, and muscle thickness estimation. In an ultrasound image sequence, we first selected two seed points in the first frame manually for the superficial and deep aponeuroses, respectively. Seed points in all following frames were then tracked by registering to their respective previous frames. Second, we adopted the local and global intensity fitting model to extract the contours of aponeuroses. At last, the muscle thickness was achieved by calculating the distance between the contours of superficial and deep aponeuroses. The performance of the algorithm was evaluated using 500 frames of ultrasound images. It was demonstrated in the experiments that the proposed methods could be used for objective tracking of aponeuroses and estimation of muscle thickness in musculoskeletal ultrasound images.

Entities:  

Mesh:

Year:  2013        PMID: 24240721     DOI: 10.1109/JBHI.2013.2253787

Source DB:  PubMed          Journal:  IEEE J Biomed Health Inform        ISSN: 2168-2194            Impact factor:   5.772


  4 in total

1.  An efficient framework for estimation of muscle fiber orientation using ultrasonography.

Authors:  Shan Ling; Bin Chen; Yongjin Zhou; Wan-Zhang Yang; Yu-Qian Zhao; Lei Wang; Yong-Ping Zheng
Journal:  Biomed Eng Online       Date:  2013-09-30       Impact factor: 2.819

2.  Objective Assessment of Regional Stiffness in Vastus Lateralis with Different Measurement Methods: A Reliability Study.

Authors:  Alfredo Bravo-Sánchez; Pablo Abián; Jorge Sánchez-Infante; Paula Esteban-Gacía; Fernando Jiménez; Javier Abián-Vicén
Journal:  Sensors (Basel)       Date:  2021-05-06       Impact factor: 3.576

3.  Relationship of EMG/SMG features and muscle strength level: an exploratory study on tibialis anterior muscles during plantar-flexion among hemiplegia patients.

Authors:  Huihui Li; Guoru Zhao; Yongjin Zhou; Xin Chen; Zhen Ji; Lei Wang
Journal:  Biomed Eng Online       Date:  2014-01-27       Impact factor: 2.819

4.  Gear Shifting of Quadriceps during Isometric Knee Extension Disclosed Using Ultrasonography.

Authors:  Shu Zhang; Weijian Huang; Yu Zeng; Wenxiu Shi; Xianfen Diao; Xiguang Wei; Shan Ling
Journal:  Biomed Res Int       Date:  2018-03-18       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.