Literature DB >> 24238753

Age-related normal range of left ventricular strain and torsion using three-dimensional speckle-tracking echocardiography.

Kyoko Kaku1, Masaaki Takeuchi2, Wendy Tsang3, Kiyohito Takigiku4, Satoshi Yasukochi4, Amit R Patel3, Victor Mor-Avi3, Roberto M Lang3, Yutaka Otsuji1.   

Abstract

BACKGROUND: Three-dimensional (3D) speckle-tracking echocardiography (STE) is an emerging technology used to quantify left ventricular (LV) function. However, the accuracy and normal values of LV strain and twist using 3D STE have not been established in a large group of normal subjects. The aims of this study were to (1) to evaluate the accuracy of 3D STE analysis of LV strain against a cardiac magnetic resonance (CMR) reference and (2) to establish age-related normal values of LV strain and torsion using real-time 3D echocardiographic (RT3DE) images.
METHODS: In protocol 1, RT3DE data sets and CMR images were acquired on the same day in 19 patients referred for clinically indicated CMR. Global LV longitudinal, circumferential, and radial strain was compared between the two modalities. In protocol 2, global and regional strain and twist and torsion were measured in 313 healthy subjects using 3D STE.
RESULTS: In protocol 1, good correlations for each LV strain component were noted between RT3DE imaging and CMR (r = 0.61-0.86, P < .001). In protocol 2, normal global longitudinal, circumferential, radial, and 3D strain were -20.3 ± 3.2%, -28.9 ± 4.6%, 88.0 ± 21.8%, and -37.6 ± 4.8%, respectively. A significant age dependency was observed for global longitudinal and 3D strain. Aging also affected LV torsion: the lowest values were found in children and adolescents, and values subsequently increased with age, while further aging was associated with a gradual reduction in basal rotation accompanied by an increase in apical rotation.
CONCLUSIONS: This study provides initial validation of 3D strain analysis from RT3DE images and reference values of normal 3D LV strain and torsion. The age-related differences in LV strain and torsion may reflect myocardial maturation and aging.
Copyright © 2014 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Keywords:  2D; 3D; 3D echocardiography; 3D speckle-tracking; CMR; Cardiac magnetic resonance; LV; Left ventricular; RT3DE; Real-time three-dimensional echocardiographic; STE; Speckle-tracking echocardiography; Strain; Three-dimensional; Torsion; Two-dimensional

Mesh:

Year:  2013        PMID: 24238753     DOI: 10.1016/j.echo.2013.10.002

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  54 in total

Review 1.  Reference Ranges of Left Ventricular Strain Measures by Two-Dimensional Speckle-Tracking Echocardiography in Children: A Systematic Review and Meta-Analysis.

Authors:  Philip T Levy; Aliza Machefsky; Aura A Sanchez; Meghna D Patel; Sarah Rogal; Susan Fowler; Lauren Yaeger; Angela Hardi; Mark R Holland; Aaron Hamvas; Gautam K Singh
Journal:  J Am Soc Echocardiogr       Date:  2015-12-30       Impact factor: 5.251

2.  Speckle tracking echocardiography assessment of global and regional contraction dysfunction in the mice model of pressure overload.

Authors:  Guan Wang; Le Zhang; Lei Ruan; Xiao-Qing Quan; Jun Yang; Cai-Xia Lv; Cun-Tai Zhang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2015-04-16

Review 3.  Review and status report of pediatric left ventricular systolic strain and strain rate nomograms.

Authors:  Massimiliano Cantinotti; Shelby Kutty; Raffaele Giordano; Nadia Assanta; Bruno Murzi; Maura Crocetti; Marco Marotta; Giorgio Iervasi
Journal:  Heart Fail Rev       Date:  2015-09       Impact factor: 4.214

Review 4.  Three-Dimensional Echocardiography: Current Status and Real-Life Applications.

Authors:  Victor Chien-Chia Wu; Masaaki Takeuchi
Journal:  Acta Cardiol Sin       Date:  2017-03       Impact factor: 2.672

5.  Advances in dual respiratory and ECG-gated SPECT imaging.

Authors:  Kenneth J Nichols; Andrew Van Tosh
Journal:  J Nucl Cardiol       Date:  2017-04-21       Impact factor: 5.952

6.  Cardiorespiratory fitness modifies the relationship between myocardial function and cerebral blood flow in older adults.

Authors:  Nathan F Johnson; Brian T Gold; Alison L Bailey; Jody L Clasey; Jonathan G Hakun; Matthew White; Doug E Long; David K Powell
Journal:  Neuroimage       Date:  2015-05-30       Impact factor: 6.556

7.  Increased apical rotation in patients with severe aortic stenosis assessed by three-dimensional speckle tracking imaging.

Authors:  Maidar Tumenbayar; Kazuto Yamaguchi; Hiroyuki Yoshitomi; Akihiro Endo; Kazuaki Tanabe
Journal:  J Echocardiogr       Date:  2017-08-11

8.  Myocardial deformational adaptations to different forms of training: a real-time three-dimensional speckle tracking echocardiographic study.

Authors:  Ines Paola Monte; Sarah Mangiafico; Sergio Buccheri; Vera Elena Bottari; Vincenzo Lavanco; Antonio Andrea Arcidiacono; Stefano Leggio; Wanda Deste; Corrado Tamburino
Journal:  Heart Vessels       Date:  2014-05-13       Impact factor: 2.037

9.  Global Longitudinal Strain at Rest for Detection of Coronary Artery Disease in Patients without Diabetes Mellitus.

Authors:  Hou-Juan Zuo; Xiu-Ting Yang; Qi-Gong Liu; Yan Zhang; He-Song Zeng; Jiang-Tao Yan; Dao-Wen Wang; Hong Wang
Journal:  Curr Med Sci       Date:  2018-06-22

Review 10.  Three-dimensional speckle-tracking echocardiography: benefits and limitations of integrating myocardial mechanics with three-dimensional imaging.

Authors:  Denisa Muraru; Alice Niero; Hugo Rodriguez-Zanella; Diana Cherata; Luigi Badano
Journal:  Cardiovasc Diagn Ther       Date:  2018-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.