Literature DB >> 24237806

The effect of the prone maximal restraint position with and without weight force on cardiac output and other hemodynamic measures.

Davut J Savaser1, Colleen Campbell, Edward M Castillo, Gary M Vilke, Christian Sloane, Tom Neuman, Allan V Hansen, Virag Shah, Theodore C Chan.   

Abstract

BACKGROUND: The prone maximal restraint (PMR) position has been used by law enforcement and emergency care personnel to restrain acutely combative or agitated individual. The position places the subject prone with wrists handcuffed behind the back and secured to the ankles. Prior work has indicated a reduction in inferior vena cava (IVC) diameter associated with this position when weight force is applied to the back. It is therefore possible that this position can negatively impact hemodynamic stability.
OBJECTIVES: We sought to measure the impact of PMR with and without weight force on measures of cardiac function including vital signs, oxygenation, stroke volume (SV), IVC diameter, cardiac output (CO) and cardiac index (CI).
METHODS: We conducted a randomized prospective cross-over experimental study of 25 healthy male volunteers (22-43 years of age) placed in 5 different body positions: supine (SU), prone (PR), prone maximal restraint with no weight force (PMR-0), prone maximal restraint with 50 lbs added to the subject's back (PMR-50), and prone maximal restraint with 100 lbs added to the subject's back (PMR-100) for 3 min. Heart rate (HR), blood pressure (BP), and oxygenation saturation (O2 sat) were monitored. In addition, echocardiography was performed to measure left ventricular outflow tract diameter (LVOTD), and SV, CO, and CI were then calculated. Data were analyzed using repeated measures ANOVA with pair-wise comparisons when appropriate to evaluate changes with each variable with respective positioning.
RESULTS: Despite a small decrease in SV between SU and PMR positions, there were no statistically significant differences in CO between the 5 different positions. There were also no differences in CI between positions other than a small decrease when comparing SU and PMR-50 only (mean difference -0.39 L/stroke, p = 0.005). There was no evidence of hemodynamic compromise in any of the PMR positions when evaluating HR, MAP or O2 sat.
CONCLUSIONS: PMR with and without weight force did not result in any changes in CO or other evidence of cardiovascular or hemodynamic compromise.
Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

Entities:  

Keywords:  Cardiovascular function; Prone restraint; Sudden custody deaths

Mesh:

Substances:

Year:  2013        PMID: 24237806     DOI: 10.1016/j.jflm.2013.08.006

Source DB:  PubMed          Journal:  J Forensic Leg Med        ISSN: 1752-928X            Impact factor:   1.614


  5 in total

1.  Sudden death during struggle in the setting of heterozygosity for a mutation in calsequesterin 2.

Authors:  Ashwyn Rajagopalan; Michael S Pollanen
Journal:  Forensic Sci Med Pathol       Date:  2015-12-15       Impact factor: 2.007

Review 2.  The role of restraint in fatal excited delirium: a research synthesis and pooled analysis.

Authors:  Ellen M F Strömmer; Wendy Leith; Maurice P Zeegers; Michael D Freeman
Journal:  Forensic Sci Med Pathol       Date:  2020-08-22       Impact factor: 2.007

3.  Acute effects of postural changes and lower body positive and negative pressure on the eye.

Authors:  M P Van Akin; O M Lantz; A M Fellows; Christine Toutain-Kidd; Michael Zegans; J C Buckey; A P Anderson
Journal:  Front Physiol       Date:  2022-08-31       Impact factor: 4.755

4.  Prone restraint cardiac arrest in in-custody and arrest-related deaths.

Authors:  Victor Weedn; Alon Steinberg; Pete Speth
Journal:  J Forensic Sci       Date:  2022-07-22       Impact factor: 1.717

Review 5.  Restraint physiology: A review of the literature.

Authors:  Gary M Vilke
Journal:  J Forensic Leg Med       Date:  2020-09-15       Impact factor: 1.614

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.