In this study, we compare two evolving techniques for obtaining high-resolution 3D anatomical data of a mouse specimen. On the one hand, we investigate cryotome-based planar epi-illumination imaging (cryo-imaging). On the other hand, we examine X-ray phase-contrast micro-computed tomography (micro-CT) using synchrotron radiation. Cryo-imaging is a technique in which an electron multiplying charge coupled camera takes images of a cryo-frozen specimen during the sectioning process. Subsequent image alignment and virtual stacking result in volumetric data. X-ray phase-contrast imaging is based on the minute refraction of X-rays inside the specimen and features higher soft-tissue contrast than conventional, attenuation-based micro-CT. To explore the potential of both techniques for studying whole mouse disease models, one mouse specimen was imaged using both techniques. Obtained data are compared visually and quantitatively, specifically with regard to the visibility of fine anatomical details. Internal structure of the mouse specimen is visible in great detail with both techniques and the study shows in particular that soft-tissue contrast is strongly enhanced in the X-ray phase images compared to the attenuation-based images. This identifies phase-contrast micro-CT as a powerful tool for the study of small animal disease models.
© 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.

Entities:  

Keywords:  Computed tomography; X-ray phase contrast; planar epi-illumination imaging

Mesh:

Year:  2013        PMID: 24237477     DOI: 10.1111/jmi.12094

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  3 in total

1.  Enhancing Tabletop X-Ray Phase Contrast Imaging with Nano-Fabrication.

Authors:  Houxun Miao; Andrew A Gomella; Katherine J Harmon; Eric E Bennett; Nicholas Chedid; Sami Znati; Alireza Panna; Barbara A Foster; Priya Bhandarkar; Han Wen
Journal:  Sci Rep       Date:  2015-08-28       Impact factor: 4.379

2.  Time resolved X-ray Dark-Field Tomography Revealing Water Transport in a Fresh Cement Sample.

Authors:  Friedrich Prade; Kai Fischer; Detlef Heinz; Pascal Meyer; Jürgen Mohr; Franz Pfeiffer
Journal:  Sci Rep       Date:  2016-06-30       Impact factor: 4.379

3.  X-ray phase microtomography with a single grating for high-throughput investigations of biological tissue.

Authors:  Marie-Christine Zdora; Joan Vila-Comamala; Georg Schulz; Anna Khimchenko; Alexander Hipp; Andrew C Cook; Daniel Dilg; Christian David; Christian Grünzweig; Christoph Rau; Pierre Thibault; Irene Zanette
Journal:  Biomed Opt Express       Date:  2017-01-31       Impact factor: 3.732