Literature DB >> 24235279

Treatment planning and image guidance for radiofrequency ablation of large tumors.

Hongliang Ren, Enrique Campos-Nanez, Ziv Yaniv, Filip Banovac, Hernan Abeledo, Nobuhiko Hata, Kevin Cleary.   

Abstract

This article addresses the two key challenges in computer-assisted percutaneous tumor ablation: planning multiple overlapping ablations for large tumors while avoiding critical structures, and executing the prescribed plan. Toward semiautomatic treatment planning for image-guided surgical interventions, we develop a systematic approach to the needle-based ablation placement task, ranging from preoperative planning algorithms to an intraoperative execution platform. The planning system incorporates clinical constraints on ablations and trajectories using a multiple objective optimization formulation, which consists of optimal path selection and ablation coverage optimization based on integer programming. The system implementation is presented and validated in both phantom and animal studies. The presented system can potentially be further extended for other ablation techniques such as cryotherapy.

Entities:  

Mesh:

Year:  2013        PMID: 24235279      PMCID: PMC4113118          DOI: 10.1109/JBHI.2013.2287202

Source DB:  PubMed          Journal:  IEEE J Biomed Health Inform        ISSN: 2168-2194            Impact factor:   5.772


  17 in total

1.  Development of an in vivo tumor-mimic model for learning radiofrequency ablation.

Authors:  M D Scott DJ; W N Young; L M Watumull; G Lindberg; J B Fleming; R V Rege; R J Brown; D B Jones
Journal:  J Gastrointest Surg       Date:  2000 Nov-Dec       Impact factor: 3.452

2.  Treatment planning for brachytherapy: an integer programming model, two computational approaches and experiments with permanent prostate implant planning.

Authors:  E K Lee; R J Gallagher; D Silvern; C S Wuu; M Zaider
Journal:  Phys Med Biol       Date:  1999-01       Impact factor: 3.609

Review 3.  Image-guided tumor ablation: standardization of terminology and reporting criteria.

Authors:  S Nahum Goldberg; Clement J Grassi; John F Cardella; J William Charboneau; Gerald D Dodd; Damian E Dupuy; Debra Gervais; Alice R Gillams; Robert A Kane; Fred T Lee; Tito Livraghi; John McGahan; David A Phillips; Hyunchul Rhim; Stuart G Silverman
Journal:  Radiology       Date:  2005-04-21       Impact factor: 11.105

4.  User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability.

Authors:  Paul A Yushkevich; Joseph Piven; Heather Cody Hazlett; Rachel Gimpel Smith; Sean Ho; James C Gee; Guido Gerig
Journal:  Neuroimage       Date:  2006-03-20       Impact factor: 6.556

5.  Trajectory optimization for the planning of percutaneous radiofrequency ablation of hepatic tumors.

Authors:  Claire Baegert; Caroline Villard; Pascal Schreck; Luc Soler; Afshin Gangi
Journal:  Comput Aided Surg       Date:  2007-03

6.  Needle-based interventions with the image-guided surgery toolkit (IGSTK): from phantoms to clinical trials.

Authors:  Ziv Yaniv; Patrick Cheng; Emmanuel Wilson; Teo Popa; David Lindisch; Enrique Campos-Nanez; Hernan Abeledo; Vance Watson; Kevin Cleary; Filip Banovac
Journal:  IEEE Trans Biomed Eng       Date:  2009-11-17       Impact factor: 4.538

7.  Passive markers for tracking surgical instruments in real-time 3-D ultrasound imaging.

Authors:  Jeffrey Stoll; Hongliang Ren; Pierre E Dupont
Journal:  IEEE Trans Med Imaging       Date:  2011-10-25       Impact factor: 10.048

8.  Hepatocellular carcinoma: radio-frequency ablation of medium and large lesions.

Authors:  T Livraghi; S N Goldberg; S Lazzaroni; F Meloni; T Ierace; L Solbiati; G S Gazelle
Journal:  Radiology       Date:  2000-03       Impact factor: 11.105

9.  Complications of radiofrequency ablation of hepatic, pulmonary, and renal neoplasms.

Authors:  Matthew J Howenstein; Kent T Sato
Journal:  Semin Intervent Radiol       Date:  2010-09       Impact factor: 1.513

10.  Large liver tumors: protocol for radiofrequency ablation and its clinical application in 110 patients--mathematic model, overlapping mode, and electrode placement process.

Authors:  Min-Hua Chen; Wei Yang; Kun Yan; Ming-Wu Zou; Luigi Solbiati; Ji-Bin Liu; Ying Dai
Journal:  Radiology       Date:  2004-05-27       Impact factor: 11.105

View more
  9 in total

1.  A new device for fiducial registration of image-guided navigation system for liver RFA.

Authors:  Nobutaka Doba; Hiroyuki Fukuda; Kazushi Numata; Yoshiteru Hao; Kouji Hara; Akito Nozaki; Masaaki Kondo; Makoto Chuma; Katsuaki Tanaka; Shigeo Takebayashi; Norihiro Koizumi; Akira Kobayashi; Junichi Tokuda; Shin Maeda
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-07-17       Impact factor: 2.924

2.  Computer-assisted planning for a concentric tube robotic system in neurosurgery.

Authors:  Josephine Granna; Arya Nabavi; Jessica Burgner-Kahrs
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-11-27       Impact factor: 2.924

3.  EView: An electric field visualization web platform for electroporation-based therapies.

Authors:  Enric Perera-Bel; Carlos Yagüe; Borja Mercadal; Mario Ceresa; Natalie Beitel-White; Rafael V Davalos; Miguel A González Ballester; Antoni Ivorra
Journal:  Comput Methods Programs Biomed       Date:  2020-08-02       Impact factor: 5.428

4.  Statistical atlas-based morphological variation analysis of the asian humerus: towards consistent allometric implant positioning.

Authors:  K Wu; K L Wong; S J K Ng; S T Quek; B Zhou; D P Murphy; Z J Daruwalla; H Ren
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-06-13       Impact factor: 2.924

5.  Automatic planning of needle placement for robot-assisted percutaneous procedures.

Authors:  Esia Belbachir; Ehsan Golkar; Bernard Bayle; Caroline Essert
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-04-18       Impact factor: 2.924

6.  Development and selection of Asian-specific humeral implants based on statistical atlas: toward planning minimally invasive surgery.

Authors:  K Wu; Z J Daruwalla; K L Wong; D Murphy; H Ren
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-01-09       Impact factor: 2.924

7.  Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy.

Authors:  Shaoli Liu; Zeyang Xia; Jianhua Liu; Jing Xu; He Ren; Tong Lu; Xiangdong Yang
Journal:  PLoS One       Date:  2016-03-16       Impact factor: 3.240

8.  A novel parallel overlapping mode for complete ablation of large benign thyroid nodules in a single-session radiofrequency ablation.

Authors:  Tao Wu; Bowen Zheng; Lei Tan; Tinghui Yin; Yufan Lian; Shicheng Xu; Jin Ye; Jie Ren
Journal:  Front Endocrinol (Lausanne)       Date:  2022-07-26       Impact factor: 6.055

9.  MRI guided procedure planning and 3D simulation for partial gland cryoablation of the prostate: a pilot study.

Authors:  Nicole Wake; Andrew B Rosenkrantz; Daniel K Sodickson; Hersh Chandarana; James S Wysock
Journal:  3D Print Med       Date:  2020-11-03
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.