Literature DB >> 24234742

Coupling a particle beam interface directly to a quadrupole ion trap mass spectrometer.

M E Bier1, P C Winkler, J R Herron.   

Abstract

A particle beam interface has been coupled to a quadrupole ion trap mass spectrometer. The system allows the collection of electron ionization mass spectra from analyte in solution. The interface incorporates a pneumatic nebulizer, a heated desolvation chamber, and a three-stage separator region. Additional helium, for improved performance, is added through stage 3. The particles formed in the interface are separated from solvent molecules and are transferred directly to the ion trap where they are expected to collide with the hot hyperbolic surface of the end cap. The end cap serves both as a heated target used to vaporize the particles and as an ion-trapping electrode. Mass analysis is achieved with the mass-selective instability scan supplemented with resonance ejection. Electron ionization spectra from 100 ng of caffeine [molecular weight (MW) = 1941; 1-naphthalenol methylcarbamate (carbaryl) (MW = 2011, 17α-hydroxyprogesterone (MW = 330), and reserpine (MW = 608) are shown using sampling by a segmented flow analysis. Some charge exchange is evident with methanol as well as self-chemical ionization at higher analyte levels. The interface shows a nonlinear caffeine calibration curve for analyte amounts below 30 ng and a more linear response at higher amounts. Caffeine was detected at 25 pmol (5 ng), with a signal-to-noise ratio of 50, 20-μL loop, full scan.

Entities:  

Year:  1993        PMID: 24234742     DOI: 10.1016/1044-0305(93)85040-5

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  9 in total

1.  Investigation of enhanced ion abundances from a carrier process in high-performance liquid chromatography particle beam mass spectrometry.

Authors:  T A Bellar; T D Behymer; W L Budde
Journal:  J Am Soc Mass Spectrom       Date:  1990-02       Impact factor: 3.109

2.  High resolution on a quadrupole ion trap mass spectrometer.

Authors:  J C Schwartz; J E Syka; I Jardine
Journal:  J Am Soc Mass Spectrom       Date:  1991-05       Impact factor: 3.109

Review 3.  New developments in biochemical mass spectrometry: electrospray ionization.

Authors:  R D Smith; J A Loo; C G Edmonds; C J Barinaga; H R Udseth
Journal:  Anal Chem       Date:  1990-05-01       Impact factor: 6.986

4.  Sampling and extra-column effects in high-performance liquid chromatography; influence of peak skew on plate count calculations.

Authors:  J J Kirkland; W W Yau; H J Stoklosa; C H Dilks
Journal:  J Chromatogr Sci       Date:  1977-08       Impact factor: 1.618

5.  Electrospray interface for liquid chromatographs and mass spectrometers.

Authors:  C M Whitehouse; R N Dreyer; M Yamashita; J B Fenn
Journal:  Anal Chem       Date:  1985-03       Impact factor: 6.986

6.  Continuous-flow sample probe for fast atom bombardment mass spectrometry.

Authors:  R M Caprioli; T Fan; J S Cottrell
Journal:  Anal Chem       Date:  1986-12       Impact factor: 6.986

Review 7.  High-performance liquid chromatography-mass spectrometry.

Authors:  M L Vestal
Journal:  Science       Date:  1984-10-19       Impact factor: 47.728

8.  Determination of benzo[a]pyrene sulfate conjugates from benzo[a]pyrene-treated cells by continuous-flow fast atom bombardment mass spectrometry.

Authors:  Y Teffera; W M Baird; D L Smith
Journal:  Anal Chem       Date:  1991-03-01       Impact factor: 6.986

9.  Use of a single-quadrupole mass spectrometer for collision-induced dissociation studies of multiply charged peptide ions produced by electrospray ionization.

Authors:  V Katta; S K Chowdhury; B T Chait
Journal:  Anal Chem       Date:  1991-01-15       Impact factor: 6.986

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.