Literature DB >> 24234503

High pressure trapping in Fourier transform mass spectrometry: A radiofrequency-only-mode event.

D L Rempel1, M L Gross.   

Abstract

A new event for the Fourier transform mass spectrometry (FTMS) sequence is developed and demonstrated. During this event, called a radiofrequency (RF)-only mode event, the typical passive cubic trap of a Fourier transform mass spectrometer is made to operate as an active quadrupole ion trap. The transition between active and passive modes is developed so that ion loss as a consequence of the transition can be held to 15% or less. The adduct of the ion-molecule reaction of the 1,3-butadiene radical cation and methyl vinyl ether was detected during the Rf-only-mode event at a helium pressure of ∼1×10(-3) torr even though this adduct is not detectable under standard FTMS operating conditions.

Entities:  

Year:  1992        PMID: 24234503     DOI: 10.1016/1044-0305(92)85037-K

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  5 in total

1.  Ion-molecule reactions.

Authors:  J H Futrell; T O Tiernan
Journal:  Science       Date:  1968-10-25       Impact factor: 47.728

2.  Parametric mode operation of a hyperbolic Penning trap for Fourier transform mass spectrometry.

Authors:  D L Rempel; E B Ledford; S K Huang; M L Gross
Journal:  Anal Chem       Date:  1987-10-15       Impact factor: 6.986

3.  Mass spectral analysis of complex lipids desorbed directly from lyophilized membranes and cells.

Authors:  D N Heller; C Fenselau; R J Cotter; P Demirev; J K Olthoff; J Honovich; M Uy; T Tanaka; Y Kishimoto
Journal:  Biochem Biophys Res Commun       Date:  1987-01-15       Impact factor: 3.575

Review 4.  Fourier transform mass spectrometry.

Authors:  M L Gross; D L Rempel
Journal:  Science       Date:  1984-10-19       Impact factor: 47.728

5.  Space charge effects in Fourier transform mass spectrometry. Mass calibration.

Authors:  E B Ledford; D L Rempel; M L Gross
Journal:  Anal Chem       Date:  1984-12       Impact factor: 6.986

  5 in total
  7 in total

1.  A dynamic ion cooling technique for FTICR mass spectrometry.

Authors:  M V Gorshkov; C D Masselon; G A Anderson; H R Udseth; R Harkewicz; R D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2001-11       Impact factor: 3.109

2.  Evaluation of different combinations of gated trapping, RF-only mode and trap compensation for in-field MALDI Fourier transform mass spectrometry.

Authors:  Jonathon K Gooden; Don L Rempel; Michael L Gross
Journal:  J Am Soc Mass Spectrom       Date:  2004-07       Impact factor: 3.109

3.  Atmospheric pressure MALDI-FTMS of normal and chemically modified RNA.

Authors:  Katherine A Kellersberger; Eizadora T Yu; Samuel I Merenbloom; Daniele Fabris
Journal:  J Am Soc Mass Spectrom       Date:  2005-02       Impact factor: 3.109

4.  Characterization of an electron ionization source trap operating in the presence of a magnetic field through computer simulation.

Authors:  Sarah Vitcher; Claude Charvy; Laurens Dudragne; Jean-Claude Tabet
Journal:  J Am Soc Mass Spectrom       Date:  2013-05-29       Impact factor: 3.109

5.  Ion cloud manipulation using the radiofrequency-only-mode as an improvement for high mass detection in fourier transform mass spectrometry.

Authors:  C B Jacoby; C L Holliman; D L Rempel; M L Gross
Journal:  J Am Soc Mass Spectrom       Date:  1993-02       Impact factor: 3.109

Review 6.  A PERSPECTIVE ON PERSONAL CONTRIBUTIONS TO FT-ICR MASS SPECTROMETRY.

Authors:  Michael L Gross; Don L Rempel
Journal:  Mass Spectrom Rev       Date:  2020-09-22       Impact factor: 10.946

7.  Direct detection and quantitation of He@C60 by ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Helen J Cooper; Christopher L Hendrickson; Alan G Marshall; R James Cross; Martin Saunders
Journal:  J Am Soc Mass Spectrom       Date:  2002-11       Impact factor: 3.109

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.