Literature DB >> 24232629

Impedance measurement system for determination of capacitive electrode coupling.

Benjamin Eilebrecht, Johannes Willkomm, Antje Pohl, Tobias Wartzek, Steffen Leonhardt.   

Abstract

Capacitive electrodes have been studied as an alternative to gel electrodes, as they allow measurement of biopotentials without conductive contact with the patient. However, because the skin interface is not as precisely defined as with gel electrodes, this could lead to signal deformation and misdiagnoses. Thus, measurement of a capacitive coupling of the electrodes may allow to draw conclusions about the applicability of such systems. In addition, combining capacitive biosignal sensing with an impedance measurement unit may enable bioimpedance measurements, from which additional information on the hydration status can be extracted. A prototype system is introduced which measures impedance over capacitive electrodes in parallel with biopotential measurements. Also presented are the first results on characterization of the skin electrode coupling achieved with the system.

Entities:  

Mesh:

Year:  2013        PMID: 24232629     DOI: 10.1109/TBCAS.2013.2237905

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  5 in total

1.  Performance of human body communication-based wearable ECG with capacitive coupling electrodes.

Authors:  Jun Sakuma; Daisuke Anzai; Jianqing Wang
Journal:  Healthc Technol Lett       Date:  2016-07-05

2.  Motion Artifact Quantification and Sensor Fusion for Unobtrusive Health Monitoring.

Authors:  Christoph Hoog Antink; Florian Schulz; Steffen Leonhardt; Marian Walter
Journal:  Sensors (Basel)       Date:  2017-12-25       Impact factor: 3.576

3.  Unobtrusive Vital Sign Monitoring in Automotive Environments-A Review.

Authors:  Steffen Leonhardt; Lennart Leicht; Daniel Teichmann
Journal:  Sensors (Basel)       Date:  2018-09-13       Impact factor: 3.576

4.  Car Seats with Capacitive ECG Electrodes Can Detect Cardiac Pacemaker Spikes.

Authors:  Durmus Umutcan Uguz; Rosalia Dettori; Andreas Napp; Marian Walter; Nikolaus Marx; Steffen Leonhardt; Christoph Hoog Antink
Journal:  Sensors (Basel)       Date:  2020-11-04       Impact factor: 3.576

5.  Registered report protocol: Developing an artifact index for capacitive electrocardiography signals acquired with an armchair.

Authors:  Joana M Warnecke; Ju Wang; Tolga Cakir; Nicolai Spicher; Nagarajan Ganapathy; Thomas M Deserno
Journal:  PLoS One       Date:  2021-07-28       Impact factor: 3.240

  5 in total