Literature DB >> 24231965

Comparison of approaches to quantify arterial damping capacity from pressurization tests on mouse conduit arteries.

Lian Tian, Zhijie Wang, Roderic S Lakes, Naomi C Chesler.   

Abstract

Large conduit arteries are not purely elastic, but viscoelastic, which affects not only the mechanical behavior but also the ventricular afterload. Different hysteresis loops such as pressure-diameter, pressure-luminal cross-sectional area (LCSA), and stress-strain have been used to estimate damping capacity, which is associated with the ratio of the dissipated energy to the stored energy. Typically, linearized methods are used to calculate the damping capacity of arteries despite the fact that arteries are nonlinearly viscoelastic. The differences in the calculated damping capacity between these hysteresis loops and the most common linear and correct nonlinear methods have not been fully examined. The purpose of this study was thus to examine these differences and to determine a preferred approach for arterial damping capacity estimation. Pressurization tests were performed on mouse extralobar pulmonary and carotid arteries in their physiological pressure ranges with pressure (P) and outer diameter (OD) measured. The P-inner diameter (ID), P-stretch, P-Almansi strain, P-Green strain, P-LCSA, and stress-strain loops (including the Cauchy and Piola-Kirchhoff stresses and Almansi and Green strains) were calculated using the P-OD data and arterial geometry. Then, the damping capacity was calculated from these loops with both linear and nonlinear methods. Our results demonstrate that the linear approach provides a reasonable approximation of damping capacity for all of the loops except the Cauchy stress-Almansi strain, for which the estimate of damping capacity was significantly smaller (22 ± 8% with the nonlinear method and 31 ± 10% with the linear method). Between healthy and diseased extralobar pulmonary arteries, both methods detected significant differences. However, the estimate of damping capacity provided by the linear method was significantly smaller (27 ± 11%) than that of the nonlinear method. We conclude that all loops except the Cauchy stress-Almansi strain loop can be used to estimate artery wall damping capacity in the physiological pressure range and the nonlinear method is recommended over the linear method.

Entities:  

Mesh:

Year:  2013        PMID: 24231965      PMCID: PMC3705827          DOI: 10.1115/1.4024135

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  23 in total

1.  Noninvasive assessment of the viscoelasticity of peripheral arteries.

Authors:  Y W Shau; C L Wang; J Y Shieh; T C Hsu
Journal:  Ultrasound Med Biol       Date:  1999-11       Impact factor: 2.998

Review 2.  Viscoelasticity of the vessel wall: the role of collagen and elastic fibers.

Authors:  F H Silver; I Horvath; D J Foran
Journal:  Crit Rev Biomed Eng       Date:  2001

Review 3.  Mechanics of the arterial wall: review and directions.

Authors:  J D Humphrey
Journal:  Crit Rev Biomed Eng       Date:  1995

4.  In vivo/in vitro comparison of rat abdominal aorta wall viscosity. Influence of endothelial function.

Authors:  P Boutouyrie; Y Bézie; P Lacolley; P Challande; P Chamiot-Clerc; A Benetos; J F de la Faverie; M Safar; S Laurent
Journal:  Arterioscler Thromb Vasc Biol       Date:  1997-07       Impact factor: 8.311

5.  Reduced hypoxic pulmonary vascular remodeling by nitric oxide from the endothelium.

Authors:  M Ozaki; S Kawashima; T Yamashita; Y Ohashi; Y Rikitake; N Inoue; K I Hirata; Y Hayashi; H Itoh; M Yokoyama
Journal:  Hypertension       Date:  2001-02       Impact factor: 10.190

6.  Viscoelastic properties of canine pulmonary arteries.

Authors:  R H Cox
Journal:  Am J Physiol       Date:  1984-01

7.  Comparison of mechanical and chemical properties of extra- and intralobar canine pulmonary arteries.

Authors:  R H Cox
Journal:  Am J Physiol       Date:  1982-02

8.  eNOS-deficient mice show reduced pulmonary vascular proliferation and remodeling to chronic hypoxia.

Authors:  T R Quinlan; D Li; V E Laubach; E G Shesely; N Zhou; R A Johns
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2000-10       Impact factor: 5.464

9.  Improved pulmonary artery buffering function during phenylephrine-induced pulmonary hypertension.

Authors:  Daniel Bia; Juan C Grignola; Ricardo L Armentano; Fernando F Ginés
Journal:  Mol Cell Biochem       Date:  2003-04       Impact factor: 3.396

10.  Evidence for in vivo carotid and femoral wall thickening in human hypertension. Groupe de Prévention Cardio-vasculaire en Médecine du Travail.

Authors:  J Gariepy; M Massonneau; J Levenson; D Heudes; A Simon
Journal:  Hypertension       Date:  1993-07       Impact factor: 10.190

View more
  2 in total

1.  Crosslinked elastic fibers are necessary for low energy loss in the ascending aorta.

Authors:  Jungsil Kim; Marius Catalin Staiculescu; Austin J Cocciolone; Hiromi Yanagisawa; Robert P Mecham; Jessica E Wagenseil
Journal:  J Biomech       Date:  2017-07-25       Impact factor: 2.712

2.  Mitochondria DNA mutations cause sex-dependent development of hypertension and alterations in cardiovascular function.

Authors:  Mark J Golob; Lian Tian; Zhijie Wang; Todd A Zimmerman; Christine A Caneba; Timothy A Hacker; Guoqing Song; Naomi C Chesler
Journal:  J Biomech       Date:  2014-12-31       Impact factor: 2.712

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.