Literature DB >> 24231963

Left ventricular finite element model bounded by a systemic circulation model.

A I Veress, G M Raymond, G T Gullberg, J B Bassingthwaighte.   

Abstract

A series of models were developed in which a circulatory system model was coupled to an existing series of finite element (FE) models of the left ventricle (LV). The circulatory models were used to provide realistic boundary conditions for the LV models. This was developed for the JSim analysis package and was composed of a systemic arterial, capillary, and venous system in a closed loop with a varying elastance LV and left atria to provide the driving pressures and flows matching those of the FE model. Three coupled models were developed, a normal LV under normotensive aortic loading (116/80 mm Hg), a mild hypertension (137/89 mm Hg) model, and a moderate hypertension model (165/100 mm Hg). The initial step in the modeling analysis was that the circulation was optimized to the end-diastolic pressure and volume values of the LV model. The cardiac FE models were then optimized to the systolic pressure/volume characteristics of the steady-state JSim circulatory model solution. Comparison of the stress predictions for the three models indicated that the mild hypertensive case produced a 21% increase in the average fiber stress levels, and the moderate hypertension case had a 36% increase in average stress. The circulatory work increased by 18% and 43% over that of the control for the mild and moderate hypertensive cases, respectively.

Entities:  

Mesh:

Year:  2013        PMID: 24231963      PMCID: PMC3705858          DOI: 10.1115/1.4023697

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  17 in total

1.  Helical myofiber orientation after myocardial infarction and left ventricular surgical restoration in sheep.

Authors:  Joseph C Walker; Julius M Guccione; Yi Jiang; Peng Zhang; Arthur W Wallace; Edward W Hsu; Mark B Ratcliffe
Journal:  J Thorac Cardiovasc Surg       Date:  2005-02       Impact factor: 5.209

2.  Theoretical impact of the injection of material into the myocardium: a finite element model simulation.

Authors:  Samuel T Wall; Joseph C Walker; Kevin E Healy; Mark B Ratcliffe; Julius M Guccione
Journal:  Circulation       Date:  2006-11-27       Impact factor: 29.690

3.  Coupling of a 3D finite element model of cardiac ventricular mechanics to lumped systems models of the systemic and pulmonic circulation.

Authors:  Roy C P Kerckhoffs; Maxwell L Neal; Quan Gu; James B Bassingthwaighte; Jeff H Omens; Andrew D McCulloch
Journal:  Ann Biomed Eng       Date:  2006-11-08       Impact factor: 3.934

4.  Subject-specific model estimation of cardiac output and blood volume during hemorrhage.

Authors:  Maxwell Lewis Neal; James B Bassingthwaighte
Journal:  Cardiovasc Eng       Date:  2007-09

5.  A coupled biventricular finite element and lumped-parameter circulatory system model of heart failure.

Authors:  Jonathan F Wenk; Liang Ge; Zhihong Zhang; Mehrdad Soleimani; D Dean Potter; Arthur W Wallace; Elaine Tseng; Mark B Ratcliffe; Julius M Guccione
Journal:  Comput Methods Biomech Biomed Engin       Date:  2012-01-16       Impact factor: 1.763

6.  MRI-based finite-element analysis of left ventricular aneurysm.

Authors:  Joseph C Walker; Mark B Ratcliffe; Peng Zhang; Arthur W Wallace; Bahar Fata; Edward W Hsu; David Saloner; Julius M Guccione
Journal:  Am J Physiol Heart Circ Physiol       Date:  2005-03-18       Impact factor: 4.733

7.  Mechanics of active contraction in cardiac muscle: Part I--Constitutive relations for fiber stress that describe deactivation.

Authors:  J M Guccione; A D McCulloch
Journal:  J Biomech Eng       Date:  1993-02       Impact factor: 2.097

8.  Normal and pathological NCAT image and phantom data based on physiologically realistic left ventricle finite-element models.

Authors:  Alexander I Veress; W Paul Segars; Jeffrey A Weiss; Benjamin M W Tsui; Grant T Gullberg
Journal:  IEEE Trans Med Imaging       Date:  2006-12       Impact factor: 10.048

9.  Regional myocardial perfusion and mechanics: a model-based method of analysis.

Authors:  R Mazhari; J H Omens; L K Waldman; A D McCulloch
Journal:  Ann Biomed Eng       Date:  1998 Sep-Oct       Impact factor: 3.934

10.  The effect of anteroapical aneurysm plication on end-systolic three-dimensional strain in the sheep: a magnetic resonance imaging tagging study.

Authors:  Julius M Guccione; Joseph C Walker; Jeremy R Beitler; Scott M Moonly; Peng Zhang; Michael A Guttman; Cengizhan Ozturk; Elliot R McVeigh; Arthur W Wallace; David A Saloner; Mark B Ratcliffe
Journal:  J Thorac Cardiovasc Surg       Date:  2006-03       Impact factor: 5.209

View more
  2 in total

1.  The direct incorporation of perfusion defect information to define ischemia and infarction in a finite element model of the left ventricle.

Authors:  Alexander I Veress; George S K Fung; Taek-Soo Lee; Benjamin M W Tsui; Gregory A Kicska; W Paul Segars; Grant T Gullberg
Journal:  J Biomech Eng       Date:  2015-02-25       Impact factor: 2.097

2.  Image reconstruction in higher dimensions: myocardial perfusion imaging of tracer dynamics with cardiac motion due to deformation and respiration.

Authors:  Uttam M Shrestha; Youngho Seo; Elias H Botvinick; Grant T Gullberg
Journal:  Phys Med Biol       Date:  2015-10-09       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.