Literature DB >> 24231852

Validation and initial application of a semiautomatic aneurysm measurement software: a tool for assessing volumetric packing attenuation.

H Takao1, T Ishibashi, T Saguchi, H Arakawa, M Ebara, K Irie, Y Murayama.   

Abstract

BACKGROUND AND
PURPOSE: Precise aneurysm measurements and volume embolization ratios are essential for long-term durability of endovascular coil embolization. We evaluated the accuracy of newly developed semiautomatic cerebral aneurysm measurement software, NeuroVision, and explored the value of volume embolization ratio in the prediction of re-treatment.
MATERIALS AND METHODS: We compared software-derived volume measurements of 4 silicone aneurysm models with those calculated with an approximation formula and ground truth values (validation study). We used NeuroVision to retrospectively evaluate outcomes of 100 unruptured aneurysms (97 patients) treated with embolization (clinical study). Aneurysm size (height, width, and neck), volume, and volume embolization ratios were calculated for 3 groups (stable, recanalization, and re-treatment) and were compared.
RESULTS: This validation study illustrated higher accuracy of NeuroVision in computing aneurysm volume compared with an approximation formula: percentage absolute errors were 4.50% ± 3.18% and 23.07% ± 17.60%, with maximal percentage absolute errors of 8.99% and 45.63%, respectively. Of 100 unruptured aneurysms, 20 recanalized and 12 were re-treated. Average volume embolization ratios of stable and re-treated aneurysms were 24.88% ± 5.91% and 20.50% ± 4.06%, respectively (P ≤ .01). The optimal volume embolization ratio cutoff point for re-treatment was < 19.15%, at which the Youden index was 0.50 (sensitivity, 58.33%; specificity, 87.50%; area under the receiver operating characteristic curve, 0.74).
CONCLUSIONS: The NeuroVision software provided accurate aneurysm volume measurements and may be a useful standardized tool to measure aneurysm size and volume, especially for multicenter clinical studies. Volume embolization ratio may be a valuable predictor of aneurysm occlusion changes.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24231852      PMCID: PMC7965803          DOI: 10.3174/ajnr.A3777

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  25 in total

1.  [Importance of an automatic measurement base on the first coil diameter in regard to coil embolization of a cerebral aneurysm].

Authors:  Takumi Kuriyama; Hajime Furukawa; Keiji Shimizu; Kumiko Oonishi; Shinji Sakai; Hirotoshi Imamura; Chiaki Sakai; Nobuyuki Sakai
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2012

2.  Estimation of the Youden Index and its associated cutoff point.

Authors:  Ronen Fluss; David Faraggi; Benjamin Reiser
Journal:  Biom J       Date:  2005-08       Impact factor: 2.207

3.  Evaluation of aneurysm stability after endovascular embolization with Guglielmi detachable coils: correlation between long-term stability and volume embolization ratio.

Authors:  Kenji Yagi; Koichi Satoh; Junichiro Satomi; Shunji Matsubara; Shinji Nagahiro
Journal:  Neurol Med Chir (Tokyo)       Date:  2005-11       Impact factor: 1.742

4.  Unruptured intracranial aneurysms treated by three-dimensional coil embolization: evaluation of the postoperative aneurysm occlusion volume.

Authors:  Jean-Noël Vallée; Laurent Pierot; Francisco Mont'alverne; Francis Turjman; Alain Bonafé; Serge Bracard; Daouda Lo; Sophie Crozier; Hugues Duffau; Hector M Barragan-Campos; Betty Jean; Remy Guillevin; Jacques Chiras
Journal:  Neuroradiology       Date:  2005-05-20       Impact factor: 2.804

5.  Natural history of the neck remnant of a cerebral aneurysm treated with the Guglielmi detachable coil system.

Authors:  M Hayakawa; Y Murayama; G R Duckwiler; Y P Gobin; G Guglielmi; F Viñuela
Journal:  J Neurosurg       Date:  2000-10       Impact factor: 5.115

6.  Initial experience with collagen-filled Guglielmi detachable coils for endovascular treatment of experimental aneurysms.

Authors:  I Szikora; A K Wakhloo; L R Guterman; T D Chavis; R C Dawson; R W Hergenrother; R H Twyford; L N Hopkins
Journal:  AJNR Am J Neuroradiol       Date:  1997-04       Impact factor: 3.825

7.  Significance of volume embolization ratio as a predictor of recanalization on endovascular treatment of cerebral aneurysms with guglielmi detachable coils.

Authors:  N Uchiyama; S Kida; M Nomura; M Hasegawa; T Yamashima; J Yamashita; O Matsui
Journal:  Interv Neuroradiol       Date:  2001-05-15       Impact factor: 1.610

8.  Matrix and bioabsorbable polymeric coils accelerate healing of intracranial aneurysms: long-term experimental study.

Authors:  Yuichi Murayama; Satoshi Tateshima; Nestor R Gonzalez; Fernando Vinuela
Journal:  Stroke       Date:  2003-07-17       Impact factor: 7.914

9.  Treatment of unruptured aneurysms with GDCs: clinical experience with 247 aneurysms.

Authors:  Nestor Gonzalez; Yuichi Murayama; Yih Lin Nien; Neil Martin; John Frazee; Gary Duckwiler; Reza Jahan; Y Pierre Gobin; Fernando Viñuela
Journal:  AJNR Am J Neuroradiol       Date:  2004-04       Impact factor: 3.825

10.  International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion.

Authors:  Andrew J Molyneux; Richard S C Kerr; Ly-Mee Yu; Mike Clarke; Mary Sneade; Julia A Yarnold; Peter Sandercock
Journal:  Lancet       Date:  2005 Sep 3-9       Impact factor: 79.321

View more
  4 in total

1.  Hemodynamics and coil distribution with changing coil stiffness and length in intracranial aneurysms.

Authors:  Soichiro Fujimura; Hiroyuki Takao; Takashi Suzuki; Chihebeddine Dahmani; Toshihiro Ishibashi; Hiroya Mamori; Makoto Yamamoto; Yuichi Murayama
Journal:  J Neurointerv Surg       Date:  2017-12-19       Impact factor: 5.836

2.  Accuracy of Length of Virtual Stents in Treatment of Intracranial Wide-Necked Aneurysms.

Authors:  Kengo Nishimura; Katharina Otani; Ashraf Mohamed; Chihebeddine Dahmani; Toshihiro Ishibashi; Ichiro Yuki; Shogo Kaku; Hiroyuki Takao; Yuichi Murayama
Journal:  Cardiovasc Intervent Radiol       Date:  2019-05-10       Impact factor: 2.740

3.  Estimated pretreatment hemodynamic prognostic factors of aneurysm recurrence after endovascular embolization.

Authors:  Kouichi Misaki; Hiroyuki Takao; Takashi Suzuki; Kengo Nishimura; Issei Kan; Ichiro Yuki; Toshihiro Ishibashi; Makoto Yamamoto; Yuichi Murayama
Journal:  Technol Health Care       Date:  2017-10-23       Impact factor: 1.285

4.  A new combined parameter predicts re-treatment for coil-embolized aneurysms: a computational fluid dynamics multivariable analysis study.

Authors:  Soichiro Fujimura; Hiroyuki Takao; Takashi Suzuki; Chihebeddine Dahmani; Toshihiro Ishibashi; Hiroya Mamori; Makoto Yamamoto; Yuichi Murayama
Journal:  J Neurointerv Surg       Date:  2017-12-15       Impact factor: 5.836

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.