Literature DB >> 24231816

Comparative study on tube-load modeling of arterial hemodynamics in humans.

Mohammad Rashedi, Nima Fazeli, Alyssa Chappell, Shaohua Wang, Roderick Macarthur, M Sean McMurtry, Barry A Finegan, Jin-Oh Hahn.   

Abstract

In this paper, we assess the validity of two alternative tube-load models for describing the relationship between central aortic and peripheral arterial blood pressure (BP) waveforms in humans. In particular, a single-tube (1-TL) model and a serially connected two-tube (2-TL) model, both terminated with a Windkessel load, are considered as candidate representations of central aortic-peripheral arterial path. Using the central aortic, radial and femoral BP waveform data collected from eight human subjects undergoing coronary artery bypass graft with cardiopulmonary bypass procedure, the fidelity of the tube-load models was quantified and compared with each other. Both models could fit the central aortic-radial and central aortic-femoral BP waveform pairs effectively. Specifically, the models could estimate pulse travel time (PTT) accurately, and the model-derived frequency response was also close to the empirical transfer function estimate obtained directly from the central aortic and peripheral BP waveform data. However, 2-TL model was consistently superior to 1-TL model with statistical significance as far as the accuracy of the central aortic BP waveform was concerned. Indeed, the average waveform RMSE was 2.52 mmHg versus 3.24 mmHg for 2-TL and 1-TL models, respectively (p < 0.05); the r² value between measured and estimated central aortic BP waveforms was 0.96 and 0.93 for 2-TL and 1-TL models, respectively (p < 0.05). We concluded that the tube-load models considered in this paper are valid representations that can accurately reproduce central aortic-radial/femoral BP waveform relationships in humans, although the 2-TL model is preferred if an accurate central aortic BP waveform is highly desired.

Entities:  

Mesh:

Year:  2013        PMID: 24231816     DOI: 10.1115/1.4023373

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  7 in total

1.  Observer-Based Deconvolution of Deterministic Input in Coprime Multichannel Systems With Its Application to Noninvasive Central Blood Pressure Monitoring.

Authors:  Zahra Ghasemi; Woongsun Jeon; Chang-Sei Kim; Anuj Gupta; Rajesh Rajamani; Jin-Oh Hahn
Journal:  J Dyn Syst Meas Control       Date:  2020-05-25       Impact factor: 1.372

2.  Subject-specific estimation of central aortic blood pressure via system identification: preliminary in-human experimental study.

Authors:  Nima Fazeli; Chang-Sei Kim; Mohammad Rashedi; Alyssa Chappell; Shaohua Wang; Roderick MacArthur; M Sean McMurtry; Barry Finegan; Jin-Oh Hahn
Journal:  Med Biol Eng Comput       Date:  2014-09-03       Impact factor: 2.602

3.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

4.  Toward a Smartphone Application for Estimation of Pulse Transit Time.

Authors:  He Liu; Kamen Ivanov; Yadong Wang; Lei Wang
Journal:  Sensors (Basel)       Date:  2015-10-27       Impact factor: 3.576

5.  Physiological Association between Limb Ballistocardiogram and Arterial Blood Pressure Waveforms: A Mathematical Model-Based Analysis.

Authors:  Peyman Yousefian; Sungtae Shin; Azin Sadat Mousavi; Chang-Sei Kim; Barry Finegan; M Sean McMurtry; Ramakrishna Mukkamala; Dae-Geun Jang; Uikun Kwon; Youn Ho Kim; Jin-Oh Hahn
Journal:  Sci Rep       Date:  2019-03-26       Impact factor: 4.379

6.  Tapered vs. Uniform Tube-Load Modeling of Blood Pressure Wave Propagation in Human Aorta.

Authors:  Azin Mousavi; Ali Tivay; Barry Finegan; Michael Sean McMurtry; Ramakrishna Mukkamala; Jin-Oh Hahn
Journal:  Front Physiol       Date:  2019-08-06       Impact factor: 4.566

7.  Improving the accuracy and robustness of carotid-femoral pulse wave velocity measurement using a simplified tube-load model.

Authors:  Lisheng Xu; Shuran Zhou; Lu Wang; Yang Yao; Liling Hao; Lin Qi; Yudong Yao; Hongguang Han; Ramakrishna Mukkamala; Stephen E Greenwald
Journal:  Sci Rep       Date:  2022-03-25       Impact factor: 4.996

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.