Literature DB >> 24226389

Automated high-speed analysis of selected organic compounds in urban air by on-line isotopic dilution cryofocusing gas chromatography/mass spectrometry.

E Davoli1, L Cappellini, M Maggi, R Fanelli.   

Abstract

An automated environmental air monitor has been developed to measure selected organic compounds in urban air. The instrument is based on a cryofocusing-thermal desorption gas chromatographic mass spectrometry technique where the mass spectrometer is a slightly modified residual gas analyzer (RGA). The RGA was chosen as a detector because the whole system must be robust for long periods, with 24-h continuous air monitoring. RCA are extremely simple and seemed the most reliable mass spectrometers for this purpose. Moreover, because they have no physically limited ion source, contamination is considerably reduced, so maintenance intervals are longer.The gas chromatograph is equipped with a computer-controlled six-way sampling valve, with a 100-mL sampling loop and thermal desorption cold trap injector. Environmental air is enriched with an isotopically labeled internal standard in the sampling line. This internal standard is added with a validated, custom-made, permeation tube device. The "on-line" internal standard provides for high quality quantitative data because all variations in instrument sensitivity in cryofocusing or in thermal desorption efficiency are taken into account. High repetition rates (down to 5 min for a full analytical cycle) are obtained with the use of an isothermal gas chromatography program, microbore capillary column, and environmental air sampling during the gas chromatography run.

Entities:  

Year:  1994        PMID: 24226389     DOI: 10.1016/1044-0305(94)80018-9

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  6 in total

1.  Urban air pollution: state of the science.

Authors:  J H Seinfeld
Journal:  Science       Date:  1989-02-10       Impact factor: 47.728

2.  Mass spectrometry: calculations.

Authors:  D A Schoeller
Journal:  J Clin Pharmacol       Date:  1986 Jul-Aug       Impact factor: 3.126

3.  Capillary chromatographic analysis of volatile organic compounds in the indoor environment.

Authors:  C W Bayer; M S Black
Journal:  J Chromatogr Sci       Date:  1987-02       Impact factor: 1.618

4.  Health and safety risk analyses: information for better decisions.

Authors:  L B Lave
Journal:  Science       Date:  1987-04-17       Impact factor: 47.728

5.  Major sources of benzene exposure.

Authors:  L A Wallace
Journal:  Environ Health Perspect       Date:  1989-07       Impact factor: 9.031

Review 6.  Reproductive and developmental toxicity of toluene: a review.

Authors:  J M Donald; K Hooper; C Hopenhayn-Rich
Journal:  Environ Health Perspect       Date:  1991-08       Impact factor: 9.031

  6 in total
  1 in total

1.  On-line monitoring of benzene air concentrations while driving in traffic by means of isotopic dilution gas chromatography/mass spectrometry.

Authors:  E Davoli; L Cappellini; M Moggi; S Ferrari; R Fanelli
Journal:  Int Arch Occup Environ Health       Date:  1996       Impact factor: 3.015

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.