Literature DB >> 24224697

Thin lenticule Descemet's stripping automated endothelial keratoplasty: single, slow pass technique.

Rasik B Vajpayee1, Prafulla K Maharana, Shreyans Jain, Namrata Sharma, Vishal Jhanji.   

Abstract

BACKGROUND: To evaluate the outcomes of single pass thin lenticule sutureless Descemet's stripping automated endothelial keratoplasty with donor lenticules prepared using a 400 μm microkeratome head.
DESIGN: Interventional case series. PARTICIPANTS: Cases with corneal endothelial dysfunction.
METHODS: Fifteen cases with corneal endothelial dysfunction (eight pseudophakic bullous keratopathy, three Fuchs' endothelial dystrophy, three congenital hereditary endothelial dystrophy and one failed graft) underwent thin lenticule Descemet's stripping automated endothelial keratoplasty at a tertiary care hospital. Donor lenticule was prepared with a single pass 400 μm Carriazo Barraquer microkeratome (Moria, Antony, France) head. Sutureless Descemet's stripping automated endothelial keratoplasty was performed in all the cases through a 3.5 mm corneoscleral tunnel using a Busin glide for graft insertion. MAIN OUTCOME MEASURES: Main parameters evaluated were postoperative donor lenticule thickness and best-corrected visual acuity.
RESULTS: Donor lenticules were harvested successfully for all 15 cases without any complications. At 6-months follow up, the mean logMAR best-corrected visual acuity improved from 1.87 ± 0.52 to 0.109 ± 0.11 (P = < 0.0001). The mean donor lenticule thickness was 111 ± 17.62 μm (range 70-134 μm) at the last follow up. The mean endothelial cell loss was 26.33 ± 1.34%. CONCLUSIONS AND RELEVANCE: Thin donor lenticules for Descemet's stripping automated endothelial keratoplasty can be safely harvested using a single pass technique with 400 μm microkeratome head and can be used for a successful Descemet's stripping automated endothelial keratoplasty surgery.
© 2013 Royal Australian and New Zealand College of Ophthalmologists.

Entities:  

Keywords:  Descemet's stripping automated endothelial keratoplasty; endothelial keratoplasty: single; keratoplasty; slow pass technique; thin lenticule Descemet's stripping automated endothelial keratoplasty

Mesh:

Year:  2013        PMID: 24224697     DOI: 10.1111/ceo.12271

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  10 in total

1.  Visual acuity and endothelial cell density with respect to the graft thickness in Descemet's stripping automated endothelial keratoplasty: one year results.

Authors:  Banu Torun Acar; Mehmet Orcun Akdemir; Suphi Acar
Journal:  Int J Ophthalmol       Date:  2014-12-18       Impact factor: 1.779

2.  Clinical study to estimate correlation between graft thickness as measured by anterior segment Optical Coherence Tomography and visual recovery after manual Descemet stripping endothelial keratoplasty.

Authors:  Rakesh Shetty; Jaya Kaushik; Arun Kumar; Ankita Singh
Journal:  Rom J Ophthalmol       Date:  2022 Apr-Jun

Review 3.  Component corneal surgery: An update.

Authors:  Prafulla K Maharana; Pranita Sahay; Deepali Singhal; Itika Garg; Jeewan S Titiyal; Namrata Sharma
Journal:  Indian J Ophthalmol       Date:  2017-08       Impact factor: 1.848

Review 4.  Descemet stripping automated endothelial keratoplasty.

Authors:  Namrata Sharma; Prafulla K Maharana; Shipra Singhi; Neelima Aron; Mukesh Patil
Journal:  Indian J Ophthalmol       Date:  2017-03       Impact factor: 1.848

5.  Commentary: Ultrathin Descemet's stripping automated endothelial keratoplasty.

Authors:  Abhishek Dave; Manisha Acharya
Journal:  Indian J Ophthalmol       Date:  2019-08       Impact factor: 1.848

6.  Commentary: Microkeratome-assisted ultrathin Descemet's stripping automated endothelial keratoplasty.

Authors:  Hariprasad Vokuda; Krishnaprasad Kudlu
Journal:  Indian J Ophthalmol       Date:  2019-08       Impact factor: 1.848

7.  Microkeratome-assisted ultrathin Descemet's stripping automated endothelial keratoplasty: A randomized trial comparing single-pass versus double-pass technique.

Authors:  Namrata Sharma; Aarifa Yasmin Hussain; Ritu Nagpal; Anubha Rathi; Prafulla K Maharana; Rajesh Sinha; Tushar Agarwal; Jeewan Singh Titiyal
Journal:  Indian J Ophthalmol       Date:  2019-08       Impact factor: 1.848

8.  Commentary: Early changes in host and donor lenticule thickness after Descemet stripping endothelial keratoplasty.

Authors:  Prafulla K Maharana; Pranita Sahay
Journal:  Indian J Ophthalmol       Date:  2022-02       Impact factor: 2.969

9.  Repeat keratoplasty in failed Descemet stripping automated endothelial keratoplasty.

Authors:  Manpreet Kaur; Jeewan S Titiyal; Meghal Gagrani; Farin Shaikh; Tushar Agarwal; Rajesh Sinha; Namrata Sharma
Journal:  Indian J Ophthalmol       Date:  2019-10       Impact factor: 1.848

10.  Microscope Integrated Optical Coherence Tomography Guided Descemet Stripping Automated Endothelial Keratoplasty in Congenital Hereditary Endothelial Dystrophy.

Authors:  Mohamed Ibrahime Asif; Rahul Kumar Bafna; Namrata Sharma; Ananya Kaginalkar; Rajesh Sinha; Tushar Agarwal; Prafulla Kumar Maharana; Manpreet Kaur; Priya Taank; Jeewan S Titiyal
Journal:  Clin Ophthalmol       Date:  2021-07-27
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.