| Literature DB >> 24223711 |
Xiaoping Kang1, Yuchang Li, Jingjing Wei, Yu Zhang, Cai Bian, Kun Wang, Xiaoyan Wu, Yi Hu, Jing Li, Yinhui Yang.
Abstract
BACKGROUND: Tick-borne encephalitis (TBE), caused by tick-borne encephalitis virus (TBEV), is an infectious disease involving the central nervous system (CNS). The pathogenesis of CNS injury has not been clearly demonstrated. Matrix metalloproteinase-9 (MMP-9) and some cytokines, such as interleukin 6 (IL-6), may play important roles in the disruption of the blood-brain barrier (BBB) and the pathogenesis of TBE.Entities:
Mesh:
Substances:
Year: 2013 PMID: 24223711 PMCID: PMC3815297 DOI: 10.1371/journal.pone.0077427
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
MMP-9 levels of CSF samples obtained from tick-borne encephalitis patients.
| No.of patients | MMP-9 Positives | mean concentration of MMP-9 of the positives (ng/ml) | ||
| IgG positive | 43 | 29 | 13 | |
| IgG negative | 29 | 1 | 3 | |
Figure 1MMP-9 concentrations in TBEV IgG-positive and -negative groups.
Diluted MMP-9 standards and CSF samples were added to commercial ELISA plates for MMP-9 detection. After incubation and washing, biotin-conjugated monoclonal antibody was used to bind the MMP-9 in the samples. Horseradish-peroxidase-conjugated avidin was used to amplify the signals. Then a substrate solution capable of reacting with horseradish peroxidase, was added to the wells to produce a color reaction proportional to the amount of MMP-9 present. The MMP-9 concentration in each sample was calculated by comparing it to a MMP-9 standard curve. All of the CSF samples were divided into two groups, TBEV IgG-positive samples and TBEV IgG-negative samples. The difference in the level of MMP-9 expression was analyzed using student t test between the two groups. The limit of detection of this MMP-9 ELISA kit was 1.25 ng/mL.
The correlation of elevation between MMP-9 and IL-6.
| IL-6 positive | IL-6 negative | total | ||||
| MMP-9 positive | 21 | 5 | 26 | |||
| MMP-9 negative | 7 | 39 | 46 | |||
| Total | 28 | 44 | 72 | |||
Figure 2Correlations among the concentrations of MMP-9 and IL-6.
The concentrations of IL-6 and MMP-9 were detected using the commercial ELISA kit, and the detection limits were 1.25 ng/mL for MMP-9 and 0.0375 ng/ml for IL-6. The correlation between the concentrations of MMP-9 and IL-6 was analyzed using Pearson statistics.
The correlation of MMP-9 elevation with disease severity.
| No.of death | No.of rerecovered | total | ||||
| MMP-9 detectable | 4 | 17 | 26 | |||
| MMP-9 undetectable | 0 | 46 | 46 | |||
| total | 4 |
| 44 | 72 | ||