Literature DB >> 24222006

Improved energy compensation for time-of-flight mass spectrometry.

R T Short1, P J Todd.   

Abstract

A model for improved energy compensation in time-of-flight (TOF) mass spectrometry has been developed and tested. This model includes effects of both the acceleration and drift region on mass resolution for surface desorption TOP mass spectrometers that employ ion mirrors to improve mass resolution. Appropriate placement of an additional stage onto the conventional one- and two-stage mirrors provides compensation for flight time spreads, caused by initial ion kinetic energy distributions, in both regions. Experimental results that validate the model calculations are presented for a modified commercial two-stage ion mirror. For example, m/†m for Na(+) was improved from ∼ 100 to ∼ 200 using only a 200-eV drift energy and a 58-cm drift path.

Year:  1994        PMID: 24222006     DOI: 10.1016/1044-0305(94)80011-1

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  6 in total

1.  Kinetic energy measurements of molecular ions ejected into an electric field by matrix-assisted laser desorption.

Authors:  J Zhou; W Ens; K G Standing; A Verentchikov
Journal:  Rapid Commun Mass Spectrom       Date:  1992-11       Impact factor: 2.419

2.  Production of very-low-energy highly charged ions by synchrotron radiation.

Authors: 
Journal:  Phys Rev Lett       Date:  1986-06-16       Impact factor: 9.161

3.  Californium-252 plasma desorption mass spectroscopy.

Authors:  R D Macfarlane; D F Torgerson
Journal:  Science       Date:  1976-03-05       Impact factor: 47.728

4.  Steep dependence of recoil-ion energy on coincident projectile and target ionization in swift ion-atom collisions.

Authors: 
Journal:  Phys Rev A Gen Phys       Date:  1987-08-15

5.  Detection, identification and structural investigation of biologically important compounds by secondary ion mass spectrometry.

Authors:  A Benninghoven; W K Sichtermann
Journal:  Anal Chem       Date:  1978-07       Impact factor: 6.986

6.  Organic ion imaging using tandem mass spectrometry.

Authors:  P J Todd; R T Short; C C Grimm; W M Holland; S P Markey
Journal:  Anal Chem       Date:  1992-09-01       Impact factor: 6.986

  6 in total
  1 in total

1.  Ideal velocity focusing in a reflectron time-of-flight mass spectrometer.

Authors:  V M Doroshenko; R J Cotter
Journal:  J Am Soc Mass Spectrom       Date:  1999-10       Impact factor: 3.109

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.