Resolution limitations from detector pulse width and jitter in a linear orthogonal-acceleration time-of-flight mass spectrometer.

J N Coles1, M Guilhaus.   

Abstract

Recent and ongoing advances in timing electronics together with the development of ionization techniques suited to time-of-flight mass spectrometry (TOF-MS) have contributed to renewed interest in this method of mass analysis. Whereas low resolving powers (m/†m < 500) were once an almost unavoidable drawback in TOF-MS, recent developments in instrument geometries have produced much higher resolving powers for many ion sources. The temporal width of detector pulses and jitter in timing electronics, however, lead to contributions to peak widths that are essentially independent of the mass-analyzer ion optics. The effective detector pulse width (†t d ≈ 1-10 ns typically) can be a limiting factor in the development of high resolution time-of-flight (TOF) instruments with modest drift lengths (∼1 m), It also reduces the mass resolution more seriously for light ions. This article presents a method for distinguishing the instrumental "ion arrival-time" resolution (R o) of a linear TOF mass analyzer from that which is locally measured at a particular mass, limited by the broadening of the detector pulse width and electronics. The method also provides an estimate of †t d, that is useful in determining the temporal performance of the detection system. The model developed here is tested with data from a recently constructed orthogonal-acceleration TOF mass spectrometer equipped with a commercially available transient recorder (a LeCroy 400-Msamplejs digital oscilloscope) from which we obtained R o = 4240 ± 100 [full width at half maximum (FWHM)) and †t d = 3.0 ± 0.1 ns (FWHM).

Entities:  

Year:  1994        PMID: 24222005     DOI: 10.1016/1044-0305(94)80010-3

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  3 in total

1.  Time-of-flight mass spectrometry for the structural analysis of biological molecules.

Authors:  R J Cotter
Journal:  Anal Chem       Date:  1992-11-01       Impact factor: 6.986

2.  Time-of-flight mass spectrometry with an electrospray ion beam.

Authors:  J G Boyle; C M Whitehouse
Journal:  Anal Chem       Date:  1992-09-15       Impact factor: 6.986

3.  A compact time-of-flight mass spectrometer for the structural analysis of biological molecules using laser desorption.

Authors:  T Cornish; R J Cotter
Journal:  Rapid Commun Mass Spectrom       Date:  1992-04       Impact factor: 2.419

  3 in total
  2 in total

1.  Miniaturized EI/Q/oa TOF mass spectrometer.

Authors:  V D Berkout; R J Cotter; D P Segers
Journal:  J Am Soc Mass Spectrom       Date:  2001-06       Impact factor: 3.109

2.  High resolution PTR-TOF: quantification and formula confirmation of VOC in real time.

Authors:  Martin Graus; Markus Müller; Armin Hansel
Journal:  J Am Soc Mass Spectrom       Date:  2010-02-10       Impact factor: 3.109

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.