Literature DB >> 24220762

Analysis of mechanical contrast in optical coherence elastography.

Kelsey M Kennedy1, Chris Ford, Brendan F Kennedy, Mark B Bush, David D Sampson.   

Abstract

Optical coherence elastography (OCE) maps the mechanical properties of tissue microstructure and has potential applications in both fundamental investigations of biomechanics and clinical medicine. We report the first analysis of contrast in OCE, including evaluation of the accuracy with which OCE images (elastograms) represent mechanical properties and the sensitivity of OCE to mechanical contrast within a sample. Using phase-sensitive compression OCE, we generate elastograms of tissue-mimicking phantoms with known mechanical properties and identify limitations on contrast imposed by sample mechanics and the imaging system, including signal-processing parameters. We also generate simulated elastograms using finite element models to perform mechanical analysis in the absence of imaging system noise. In both experiments and simulations, we illustrate artifacts that degrade elastogram accuracy, depending on sample geometry, elasticity contrast between features, and surface conditions. We experimentally demonstrate sensitivity to features with elasticity contrast as small as 1.1∶1 and calculate, based on our imaging system parameters, a theoretical maximum sensitivity to elasticity contrast of 1.002∶1. The results highlight the microstrain sensitivity of compression OCE, at a spatial resolution of tens of micrometers, suggesting its potential for the detection of minute changes in elasticity within heterogeneous tissue.

Mesh:

Year:  2013        PMID: 24220762     DOI: 10.1117/1.JBO.18.12.121508

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  26 in total

1.  Mechanical contrast in spectroscopic magnetomotive optical coherence elastography.

Authors:  Adeel Ahmad; Pin-Chieh Huang; Nahil A Sobh; Paritosh Pande; Jongsik Kim; Stephen A Boppart
Journal:  Phys Med Biol       Date:  2015-08-13       Impact factor: 3.609

2.  Analysis of image formation in optical coherence elastography using a multiphysics approach.

Authors:  Lixin Chin; Andrea Curatolo; Brendan F Kennedy; Barry J Doyle; Peter R T Munro; Robert A McLaughlin; David D Sampson
Journal:  Biomed Opt Express       Date:  2014-08-01       Impact factor: 3.732

3.  Three-dimensional optical coherence micro-elastography of skeletal muscle tissue.

Authors:  Lixin Chin; Brendan F Kennedy; Kelsey M Kennedy; Philip Wijesinghe; Gavin J Pinniger; Jessica R Terrill; Robert A McLaughlin; David D Sampson
Journal:  Biomed Opt Express       Date:  2014-08-22       Impact factor: 3.732

4.  Assessing age-related changes in the biomechanical properties of rabbit lens using a coaligned ultrasound and optical coherence elastography system.

Authors:  Chen Wu; Zhaolong Han; Shang Wang; Jiasong Li; Manmohan Singh; Chih-Hao Liu; Salavat Aglyamov; Stanislav Emelianov; Fabrice Manns; Kirill V Larin
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-01-22       Impact factor: 4.799

5.  Computational optical palpation: a finite-element approach to micro-scale tactile imaging using a compliant sensor.

Authors:  Philip Wijesinghe; David D Sampson; Brendan F Kennedy
Journal:  J R Soc Interface       Date:  2017-03       Impact factor: 4.118

Review 6.  Optical coherence elastography - OCT at work in tissue biomechanics [Invited].

Authors:  Kirill V Larin; David D Sampson
Journal:  Biomed Opt Express       Date:  2017-01-27       Impact factor: 3.732

7.  In vivo volumetric quantitative micro-elastography of human skin.

Authors:  Shaghayegh Es'haghian; Kelsey M Kennedy; Peijun Gong; Qingyun Li; Lixin Chin; Philip Wijesinghe; David D Sampson; Robert A McLaughlin; Brendan F Kennedy
Journal:  Biomed Opt Express       Date:  2017-04-10       Impact factor: 3.732

8.  Wide-field optical coherence micro-elastography for intraoperative assessment of human breast cancer margins.

Authors:  Wes M Allen; Lixin Chin; Philip Wijesinghe; Rodney W Kirk; Bruce Latham; David D Sampson; Christobel M Saunders; Brendan F Kennedy
Journal:  Biomed Opt Express       Date:  2016-09-19       Impact factor: 3.732

9.  Optical coherence micro-elastography: mechanical-contrast imaging of tissue microstructure.

Authors:  Brendan F Kennedy; Robert A McLaughlin; Kelsey M Kennedy; Lixin Chin; Andrea Curatolo; Alan Tien; Bruce Latham; Christobel M Saunders; David D Sampson
Journal:  Biomed Opt Express       Date:  2014-06-09       Impact factor: 3.732

10.  Wide-field quantitative micro-elastography of human breast tissue.

Authors:  Wes M Allen; Kelsey M Kennedy; Qi Fang; Lixin Chin; Andrea Curatolo; Lucinda Watts; Renate Zilkens; Synn Lynn Chin; Benjamin F Dessauvagie; Bruce Latham; Christobel M Saunders; Brendan F Kennedy
Journal:  Biomed Opt Express       Date:  2018-02-09       Impact factor: 3.732

View more