Literature DB >> 24220512

Gold nanoparticle based Tuberculosis immunochromatographic assay: the quantitative ESE Quanti analysis of the intensity of test and control lines.

Phumlani Mdluli1, Phumlani Tetyana2, Ndabenhle Sosibo2, Hendriëtte van der Walt2, Mbuso Mlambo2, Amanda Skepu2, Robert Tshikhudo2.   

Abstract

A rapid dual channel lateral flow assay for the detection of Mycobacterium Tuberculosis antibodies (MTB 38 kDa monoclonal antibody) in human blood was developed. The MTB 6-14-38 kDa fusion antigen and anti-Protein A were used as the capture proteins for test and control lines respectively. Protein A labeled 40 nm gold nanoparticles were used as the detection conjugate. Whole blood and serum were spiked with MTB 38 kDa monoclonal antibody to make a positive sample model. The developed lateral flow was used to test MTB 38 kDa monoclonal antibody, and a detection limit of 5 ng/ml was used as a cut-off concentration of the analytes. The effect of the analyte concentration on the MTB lateral flow assay was studied using the variation of the intensity obtained from a ESE Quanti reader. There was a direct correlation between the analyte (MTB 38 kDa monoclonal antibody) concentration and the intensity of the test line. The intensity increased with an increase in the concentration of MTB 38 kDa monoclonal antibody, while in contrast, an increase in analyte concentration decreased the intensity of the control line.
© 2013 Published by Elsevier B.V.

Entities:  

Keywords:  ESE Quanti reader; Gold nanoparticles; Mycobacterium tuberculosis

Mesh:

Substances:

Year:  2013        PMID: 24220512     DOI: 10.1016/j.bios.2013.10.019

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

Review 1.  Recent advances in gold nanoparticle-based lateral flow immunoassay for the detection of bacterial infection.

Authors:  Yachana Gupta; Aditya Sharma Ghrera
Journal:  Arch Microbiol       Date:  2021-06-04       Impact factor: 2.552

2.  A rapid lateral flow immunoassay for the detection of tyrosine phosphatase-like protein IA-2 autoantibodies in human serum.

Authors:  Ingrid Kikkas; Roberto Mallone; Etienne Larger; Hervé Volland; Nathalie Morel
Journal:  PLoS One       Date:  2014-07-21       Impact factor: 3.240

3.  Theoretical and Experimental Comparison of Different Formats of Immunochromatographic Serodiagnostics.

Authors:  Dmitriy V Sotnikov; Anatoly V Zherdev; Boris B Dzantiev
Journal:  Sensors (Basel)       Date:  2017-12-25       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.