Literature DB >> 24220040

Detection of optical neuronal signals in the visual cortex using continuous wave near-infrared spectroscopy.

Bailei Sun1, Lei Zhang1, Hui Gong1, Jinyan Sun1, Qingming Luo2.   

Abstract

Near-infrared spectroscopy (NIRS) measures slow hemodynamic signals noninvasively to indirectly infer the neuronal activity in the brain. However, it remains a controversy on whether this optical measurement technique can detect the optical neuronal signal, which reflects the optical changes directly associated with neuronal activity, within the visual cortex of human and non-human primates. By carefully reviewing the important factors in the detection of optical neuronal signals, we aim to investigate the feasibility of performing NIRS measurements of optical neuronal signals within the visual cortex in humans. To ensure a strong optical neuronal response, a full-field circular black and white reversing checkerboard stimulus was presented, and the reversal frequency was carefully chosen. We used a homemade continuous wave (CW) NIRS system with high detection sensitivity (of the order of 0.1 pW) to record a large area of the visual cortex (approximately 6 × 14 cm(2)). EEG was simultaneously acquired with the optical signal. Based on the mathematical morphology, we adapted the filter proposed by Gratton et al. to remove the influence of arterial pulsation and facilitate the detection and elimination of unknown artifacts from the data. We obtained reliable optical neuronal signals in 77% of the participants (10 out of 13). The amplitudes (latencies) of the obtained optical neuronal signals corresponding to the 785 and 850 nm wavelengths were 0.017 ± 0.003% (94.7 ± 8.4 ms) and 0.025 ± 0.006% (99.0 ± 7.7 ms), respectively. There were no significant differences between the latencies of the N75 component of the visual evoked potential (VEP) and optical neuronal signals at either wavelength. This is the first study to report optical neuronal signals within the visual cortex in the intact human brain using a CW NIRS system. These results indicate the feasibility of measuring noninvasive optical neuronal signals using a CW NIRS system with high detection sensitivity.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  NIRS; Optical neuronal signal; Visual cortex; Visual evoked potential

Mesh:

Year:  2013        PMID: 24220040     DOI: 10.1016/j.neuroimage.2013.11.003

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  9 in total

1.  In-vivo multilaboratory investigation of the optical properties of the human head.

Authors:  Andrea Farina; Alessandro Torricelli; Ilaria Bargigia; Lorenzo Spinelli; Rinaldo Cubeddu; Florian Foschum; Marion Jäger; Emanuel Simon; Oliver Fugger; Alwin Kienle; Fabrizio Martelli; Paola Di Ninni; Giovanni Zaccanti; Daniel Milej; Piotr Sawosz; Michał Kacprzak; Adam Liebert; Antonio Pifferi
Journal:  Biomed Opt Express       Date:  2015-06-18       Impact factor: 3.732

Review 2.  Neurophotonics: non-invasive optical techniques for monitoring brain functions.

Authors:  Alessandro Torricelli; Davide Contini; Alberto Dalla Mora; Antonio Pifferi; Rebecca Re; Lucia Zucchelli; Matteo Caffini; Andrea Farina; Lorenzo Spinelli
Journal:  Funct Neurol       Date:  2014 Oct-Dec

3.  Hemispheric differences in electrical and hemodynamic responses during hemifield visual stimulation with graded contrasts.

Authors:  Juanning Si; Xin Zhang; Yujin Zhang; Tianzi Jiang
Journal:  Biomed Opt Express       Date:  2017-03-02       Impact factor: 3.732

4.  Dynamics of alpha control: preparatory suppression of posterior alpha oscillations by frontal modulators revealed with combined EEG and event-related optical signal.

Authors:  Kyle E Mathewson; Diane M Beck; Tony Ro; Edward L Maclin; Kathy A Low; Monica Fabiani; Gabriele Gratton
Journal:  J Cogn Neurosci       Date:  2014-04-04       Impact factor: 3.225

5.  Reduced Haemodynamic Response in the Ageing Visual Cortex Measured by Absolute fNIRS.

Authors:  Laura McKernan Ward; Ross Thomas Aitchison; Melisa Tawse; Anita Jane Simmers; Uma Shahani
Journal:  PLoS One       Date:  2015-04-24       Impact factor: 3.240

Review 6.  Frequency-Domain Techniques for Cerebral and Functional Near-Infrared Spectroscopy.

Authors:  Sergio Fantini; Angelo Sassaroli
Journal:  Front Neurosci       Date:  2020-04-07       Impact factor: 4.677

7.  Connectivity properties in the prefrontal cortex during working memory: a near-infrared spectroscopy study.

Authors:  Jinyan Sun; Fang Liu; Haixian Wang; Anping Yang; Chenyang Gao; Zhicong Li; Xiangning Li
Journal:  J Biomed Opt       Date:  2019-03       Impact factor: 3.170

8.  Measuring visual cortical oxygenation in diabetes using functional near-infrared spectroscopy.

Authors:  Ross T Aitchison; Laura Ward; Graeme J Kennedy; Xinhua Shu; David C Mansfield; Uma Shahani
Journal:  Acta Diabetol       Date:  2018-08-06       Impact factor: 4.280

9.  Age-Related Changes in Global Motion Coherence: Conflicting Haemodynamic and Perceptual Responses.

Authors:  Laura McKernan Ward; Gordon Morison; Anita Jane Simmers; Uma Shahani
Journal:  Sci Rep       Date:  2018-07-03       Impact factor: 4.379

  9 in total