Inactivation, reactivation and regrowth of indigenous bacteria in reclaimed water after chlorine disinfection of a municipal wastewater treatment plant.

Dan Li1, Siyu Zeng, April Z Gu, Miao He, Hanchang Shi.   

Abstract

Disinfection of reclaimed water prior to reuse is important to prevent the transmission of pathogens. Chlorine is a widely utilized disinfectant and as such is a leading contender for disinfection of reclaimed water. To understand the risks of chlorination resulting from the potential selection of pathogenic bacteria, the inactivation, reactivation and regrowth rates of indigenous bacteria were investigated in reclaimed water after chlorine disinfection. Inactivation of total coliforms, Enterococcus and Salmonella showed linear correlations, with constants of 0.1384, 0.1624 and 0.057 L/(mg.min) and R2 of 0.7617, 0.8316 and 0.845, respectively. However, inactivation of total viable cells by measurement of metabolic activity typically showed a linear correlation at lower chlorine dose (0-22 (mg-min)/L), and a trailing region with chlorine dose increasing from 22 to 69 (mg.min)/L. Reactivation and regrowth of bacteria were most likely to occur after exposure to lower chlorine doses, and extents of reactivation decreased gradually with increasing chlorine dose. In contrast to total coliforms and Enterococcus, Salmonella had a high level of regrowth and reactivation, and still had 2% regrowth even after chlorination of 69 (mg.min)/L and 24 hr storage. The bacterial compositions were also significantly altered by chlorination and storage of reclaimed water, and the ratio of Salmonella was significantly increased from 0.001% to 0.045% after chlorination of 69 (mg.min)/L and 24 hr storage. These trends indicated that chlorination contributes to the selection of chlorine-resistant pathogenic bacteria, and regrowth of pathogenic bacteria after chlorination in reclaimed water with a long retention time could threaten public health security during wastewater reuse.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24218842     DOI: 10.1016/s1001-0742(12)60176-4

Source DB:  PubMed          Journal:  J Environ Sci (China)        ISSN: 1001-0742            Impact factor:   5.565


  12 in total

1.  Detection of pathogenic Campylobacter, E. coli O157:H7 and Salmonella spp. in wastewater by PCR assay.

Authors:  Si Bonetta; C Pignata; E Lorenzi; M De Ceglia; L Meucci; Sa Bonetta; G Gilli; E Carraro
Journal:  Environ Sci Pollut Res Int       Date:  2016-04-23       Impact factor: 4.223

2.  Source identification of bacterial and viral pathogens and their survival/fading in the process of wastewater treatment, reclamation, and environmental reuse.

Authors:  Jinhong Zhou; Xiaochang C Wang; Zheng Ji; Limei Xu; Zhenzhen Yu
Journal:  World J Microbiol Biotechnol       Date:  2014-11-06       Impact factor: 3.312

3.  Assessment of physicochemical parameters and prevalence of virulent and multiple-antibiotic-resistant Escherichia coli in treated effluent of two wastewater treatment plants and receiving aquatic milieu in Durban, South Africa.

Authors:  Leanne Pillay; Ademola O Olaniran
Journal:  Environ Monit Assess       Date:  2016-04-01       Impact factor: 2.513

4.  Metagenomic insights into dissemination of antibiotic resistance across bacterial genera in wastewater treatment.

Authors:  Xiaoxiao Cheng; Jiannong Xu; Geoffrey Smith; Yanyan Zhang
Journal:  Chemosphere       Date:  2021-01-07       Impact factor: 7.086

5.  Electrochemical disinfection of toilet wastewater using wastewater electrolysis cell.

Authors:  Xiao Huang; Yan Qu; Clément A Cid; Cody Finke; Michael R Hoffmann; Keahying Lim; Sunny C Jiang
Journal:  Water Res       Date:  2016-01-21       Impact factor: 11.236

6.  Molecular-based detection of potentially pathogenic bacteria in membrane bioreactor (MBR) systems treating municipal wastewater: a case study.

Authors:  Moustapha Harb; Pei-Ying Hong
Journal:  Environ Sci Pollut Res Int       Date:  2016-12-24       Impact factor: 4.223

7.  Induction of Escherichia coli Into a VBNC State by Continuous-Flow UVC and Subsequent Changes in Metabolic Activity at the Single-Cell Level.

Authors:  Shenghua Zhang; Lizheng Guo; Kai Yang; Yin Zhang; Chengsong Ye; Sheng Chen; Xin Yu; Wei E Huang; Li Cui
Journal:  Front Microbiol       Date:  2018-09-25       Impact factor: 5.640

8.  Effect of Chlorination on Microbiological Quality of Effluent of a Full-Scale Wastewater Treatment Plant.

Authors:  Ioanna Zerva; Nikolaos Remmas; Ifigeneia Kagalou; Paraschos Melidis; Marina Ariantsi; Georgios Sylaios; Spyridon Ntougias
Journal:  Life (Basel)       Date:  2021-01-19

9.  Comparison of UV, Peracetic Acid and Sodium Hypochlorite Treatment in the Disinfection of Urban Wastewater.

Authors:  Silvia Bonetta; Cristina Pignata; Sara Bonetta; Giulia Amagliani; Giorgio Brandi; Giorgio Gilli; Elisabetta Carraro
Journal:  Pathogens       Date:  2021-02-09

10.  Controlling Bacterial Pathogens in Water for Reuse: Treatment Technologies for Water Recirculation in the Blue Diversion Autarky Toilet.

Authors:  Mi T Nguyen; Lukas Allemann; Christopher Ziemba; Odile Larive; Eberhard Morgenroth; Timothy R Julian
Journal:  Front Environ Sci       Date:  2017-12-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.