Literature DB >> 24216207

Analytical isotachophoresis of lactate in human serum using dry film photoresist microfluidic chips compatible with a commercially available field-deployable instrument platform.

Petr Smejkal1, Michael C Breadmore, Rosanne M Guijt, František Foret, Fritz Bek, Mirek Macka.   

Abstract

A dry film resist (DFR) chip compatible with the Agilent Bioanalyzer 2100 was designed and fabricated for use in the analysis of lactate in serum by chip isotachophoresis (ITP). The Agilent Bioanalyzer 2100 is a commercially available field deployable analytical instrument originally developed for the electrophoretic analysis of DNA, RNA and proteins. The DFR chip was designed for the ITP separation of lactate in human serum within 1 min and was made compatible with the Bioanalyzer after packaging in the plastic caddies normally used for the DNA chips. A 20-fold improvement in sensitivity was obtained for the DFR chips in comparison with the standard chips used in earlier work. The limit of detection and limit of quantification for lactate were 24 μM and 80 μM, respectively. This new approach enables the use of commercial platforms like the Agilent Bioanalyzer for new applications including the analysis of small molecules.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  DFR; Fluorescence; HPMC; Indirect detection; Isotachophoresis; LE; Microfluidics; PC; R6G; Serum; TE; dry film resist; hydroxypropylmethyl cellulose; leading electrolyte; polycarbonate; rhodamine 6G; terminating electrolyte

Mesh:

Substances:

Year:  2013        PMID: 24216207     DOI: 10.1016/j.aca.2013.01.046

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

Review 1.  Isotachophoresis: Theory and Microfluidic Applications.

Authors:  Ashwin Ramachandran; Juan G Santiago
Journal:  Chem Rev       Date:  2022-06-22       Impact factor: 72.087

2.  The characterization of four gene expression analysis in circulating tumor cells made by Multiplex-PCR from the AdnaTest kit on the lab-on-a-chip Agilent DNA 1000 platform.

Authors:  Markéta Škereňová; Veronika Mikulová; Otakar Čapoun; Tomáš Zima
Journal:  Biochem Med (Zagreb)       Date:  2016       Impact factor: 2.313

3.  High-Throughput Fabrication of Flexible and Transparent All-Carbon Nanotube Electronics.

Authors:  Yong-Yang Chen; Yun Sun; Qian-Bing Zhu; Bing-Wei Wang; Xin Yan; Song Qiu; Qing-Wen Li; Peng-Xiang Hou; Chang Liu; Dong-Ming Sun; Hui-Ming Cheng
Journal:  Adv Sci (Weinh)       Date:  2018-02-20       Impact factor: 16.806

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.