Literature DB >> 24216203

The use of a polymer inclusion membrane in a paper-based sensor for the selective determination of Cu(II).

B Manori Jayawardane1, Lilibeth dlC Coo, Robert W Cattrall, Spas D Kolev.   

Abstract

A disposable paper-based sensor (PBS) is described for the determination of Cu(II) in natural and waste waters at approximately 2 cents per measurement. The device makes use of a polymer inclusion membrane (PIM) to provide the selectivity for Cu(II). The PIM consists of 40 wt% di(2-ethlyhexyl) phosphoric acid (D2EHPA) as the carrier, 10 wt% dioctyl phthalate (DOP) as a plasticizer, 49.5 wt% poly(vinyl chloride) (PVC) as the base polymer and 0.5 wt% (mm(-1)) 1-(2'-pyridylazo)-2-naphthol (PAN) as the colourimetric reagent. High selectivity under mildly acidic conditions (HCl, pH 2.0) is achieved for Cu(II) in the presence of frequently encountered metal ions in natural and waste waters such as Fe(III), Al(III), Zn(II), Cd(II), Pb(II), Ca(II), Mg(II), and Ni(II). The laminated PBS consists of a PIM sensing disc (2mm in diameter) attached to the centre of a circular hydrophilic zone (7 mm in diameter) pretreated with 0.01 M HCl. This hydrophilic zone separates the sample port (a circular hole in the plastic cover) from the PIM sensing disc. After introducing 19.2 μL of a sample/standard solution to the sample port, Cu(II) diffuses across the hydrophilic zone and is extracted into the PIM disc as the Cu(II)-D2EHPA complex which subsequently reacts with PAN to produce the red-purple coloured Cu(II)-PAN complex. The colour intensity of the PIM disc is measured 15 min after sample/standard introduction by scanning using a flatbed scanner. Under optimal conditions the device is characterized by a limit of detection (LOD) and limit of quantitation (LOQ) of 0.06 and 0.21 mg L(-1) Cu(II), respectively, with two linear ranges together covering the Cu(II) concentration range from 0.1 to 30.0 mg L(-1). The PBS was successfully applied to the determination of Cu(II) in hot tap water and mine tailings water.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  1-(2-Pyridylazo)-2-naphthol (PAN); Detection of Cu(II); Di(2-ethlyhexyl) phosphoric acid (D2EHPA); Paper-based sensor (PBS); Polymer inclusion membrane (PIM)

Mesh:

Substances:

Year:  2013        PMID: 24216203     DOI: 10.1016/j.aca.2013.07.029

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  6 in total

1.  Paper-based plasticizer-free sodium ion-selective sensor with camera phone as a detector.

Authors:  Xuewei Wang; Yu Qin; Mark E Meyerhoff
Journal:  Chem Commun (Camb)       Date:  2015-09-01       Impact factor: 6.222

Review 2.  Paper-based analytical devices for environmental analysis.

Authors:  Nathan A Meredith; Casey Quinn; David M Cate; Thomas H Reilly; John Volckens; Charles S Henry
Journal:  Analyst       Date:  2016-03-21       Impact factor: 5.227

Review 3.  Advances in Microfluidic Paper-Based Analytical Devices for Food and Water Analysis.

Authors:  Lori Shayne Alamo Busa; Saeed Mohammadi; Masatoshi Maeki; Akihiko Ishida; Hirofumi Tani; Manabu Tokeshi
Journal:  Micromachines (Basel)       Date:  2016-05-09       Impact factor: 2.891

4.  Integration of Response Surface Methodology (RSM) and Principal Component Analysis (PCA) as an Optimization Tool for Polymer Inclusion Membrane Based-Optodes Designed for Hg(II), Cd(II), and Pb(II).

Authors:  Jeniffer García-Beleño; Eduardo Rodríguez de San Miguel
Journal:  Membranes (Basel)       Date:  2021-04-14

Review 5.  Application of Microfluidic Chip Technology in Food Safety Sensing.

Authors:  Hongwei Gao; Chunlei Yan; Wei Wu; Juan Li
Journal:  Sensors (Basel)       Date:  2020-03-24       Impact factor: 3.576

6.  [Applications of microfluidic paper-based chips in environmental analysis and detection].

Authors:  Yu Zhang; Ji Qi; Feng Liu; Ning Wang; Xiyan Sun; Rong Cui; Jialuo Yu; Jiaming Ye; Ping Liu; Bowei Li; Lingxin Chen
Journal:  Se Pu       Date:  2021-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.