Literature DB >> 24216200

The use of a polymer inclusion membrane for separation and preconcentration of orthophosphate in flow analysis.

Edward A Nagul1, Clàudia Fontàs, Ian D McKelvie, Robert W Cattrall, Spas D Kolev.   

Abstract

A highly sensitive flow analysis system has been developed for the trace determination of reactive phosphate in natural waters, which uses a polymer inclusion membrane (PIM) with Aliquat 336 as the carrier for on-line analyte separation and preconcentration. The system operates under flow injection (FI) and continuous flow (CF) conditions. Under optimal FI conditions the system is characterised by a linear concentration range between 0.5 and 1000 μg L(-1)P, a sampling rate of 10h(-1), a limit of detection of 0.5 μgL(-1)P and RSDs of 3.2% (n = 10, 100 μg L(-1)) and 7.7% (n = 10, 10 μg L(-1)). Under CF conditions with 10 min stop-flow time and sample solution flow rate of 1.32 mL min(-1) the flow system offers a limit of detection of 0.04 μg L(-1)P, a sampling rate of 5h(-1) and an RSD of 3.4% (n=5, 2.0 μg L(-1)). Interference studies revealed that anions commonly found in natural waters did not interfere when in excess of at least one order of magnitude. The flow system, operating under CF conditions, was successfully applied to the analysis of natural water samples containing concentrations of phosphate in the low μg L(-1)P range, using the multipoint standard addition method.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aliquat 336; Extraction; Flow injection analysis; Molybdenum blue method; Phosphate determination; Polymer inclusion membrane

Mesh:

Substances:

Year:  2013        PMID: 24216200     DOI: 10.1016/j.aca.2013.07.052

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Exploring new DGT samplers containing a polymer inclusion membrane for mercury monitoring.

Authors:  Marta Turull; Gemma Elias; Clàudia Fontàs; Sergi Díez
Journal:  Environ Sci Pollut Res Int       Date:  2016-05-18       Impact factor: 4.223

Review 2.  Flow-Injection Methods in Water Analysis-Recent Developments.

Authors:  Marek Trojanowicz; Marta Pyszynska
Journal:  Molecules       Date:  2022-02-19       Impact factor: 4.411

3.  The Effect of Surface Confined Gold Nanoparticles in Blocking the Extraction of Nitrate by PVC-Based Polymer Inclusion Membranes Containing Aliquat 336 as the Carrier.

Authors:  Ya Ya N Bonggotgetsakul; Robert W Cattrall; Spas D Kolev
Journal:  Membranes (Basel)       Date:  2018-01-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.