Comparison of ICD implantation in obese and nonobese patients.

Ganesh Venkataraman1, Deepti Mathur, Siddhi Joshi, Adam Strickberger.   

Abstract

BACKGROUND: Implantable defibrillator (ICD) therapy improves mortality in patients at risk for sudden cardiac death. Obese patients pose challenges during ICD implantation and may have an increased risk of procedure-related complications. The comparison of acute procedural success and safety of ICD implantation in obese and nonobese patients has not been previously reported.
METHODS: A total of 181 patients underwent ICD implantation at a single institution. Obesity was defined as a body mass index (BMI) greater than or equal to 30 kg/m(2) . Acute safety and efficacy data were collected and analyzed from a prospectively maintained database, with retrospective chart review, as required.
RESULTS: Among the 181 patients, 58 (32.0%) were obese. Mean BMI was 36.7 ± 6.3 kg/m(2) among obese patients and was 24.6 ± 3.1 kg/m(2) among nonobese patients (P < 0.001). Successful ICD implantation occurred in 58 of 58 (100%) obese patients and 122 of 123 (99.2%) nonobese patients (P = 1.0). A complication was observed in three of 58 (5.2%) obese patients and in seven of 123 (5.7%) nonobese patients (P = 1.0). Similarly, there was no difference in acute procedural success and safety in patients receiving a cardiac resynchronization therapy (CRT)-ICD.
CONCLUSIONS: Acute success and safety of ICD implantation is similar in both obese and nonobese patients. This finding extended to patients treated with a CRT-ICD and among patients with extreme obesity. Obesity should probably not be a factor in determining whether a patient is a candidate for ICD implantation. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  device complications; heart failure; implantable defibrillator; obesity; procedural success

Mesh:

Year:  2013        PMID: 24215359     DOI: 10.1111/pace.12297

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

Review 1.  "Beauty is a light in the heart": the transformative potential of optogenetics for clinical applications in cardiovascular medicine.

Authors:  Patrick M Boyle; Thomas V Karathanos; Natalia A Trayanova
Journal:  Trends Cardiovasc Med       Date:  2014-10-16       Impact factor: 6.677

2.  Cardiac device implantations in obese patients: Success rates and complications.

Authors:  Philipp Attanasio; Philipp Lacour; Andrea Ernert; Burkert Pieske; Wilhelm Haverkamp; Florian Blaschke; Francesco Dalle Vedove; Martin Huemer
Journal:  Clin Cardiol       Date:  2017-03-23       Impact factor: 2.882

3.  Association of body mass index with cardiac resynchronization therapy intention and left ventricular lead implantation failure: insights from the NCDR implantable cardioverter-defibrillator registry.

Authors:  Marin Nishimura; Gregory M Marcus; Paul D Varosy; Haikun Bao; Yongfei Wang; Jeptha P Curtis; Jonathan C Hsu
Journal:  J Interv Card Electrophysiol       Date:  2019-04-19       Impact factor: 1.900

4.  Effect of obesity on the effectiveness of cardiac resynchronization to reduce the risk of first and recurrent ventricular tachyarrhythmia events.

Authors:  Barbara Szepietowska; Bronislava Polonsky; Saadia Sherazi; Yitschak Biton; Valentina Kutyifa; Scott McNitt; Mehmet Aktas; Arthur J Moss; Wojciech Zareba
Journal:  Cardiovasc Diabetol       Date:  2016-07-07       Impact factor: 9.951

Review 5.  Cardiac Optogenetics in Atrial Fibrillation: Current Challenges and Future Opportunities.

Authors:  Mariana Floria; Smaranda Radu; Evelina Maria Gosav; Aurelian Corneliu Moraru; Teodor Serban; Alexandru Carauleanu; Claudia Florida Costea; Anca Ouatu; Manuela Ciocoiu; Daniela Maria Tanase
Journal:  Biomed Res Int       Date:  2020-10-27       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.