Literature DB >> 24214518

The accuracy of a disposable noninvasive core thermometer.

Oliver Kimberger1, Leif Saager, Cameron Egan, Ivan Parra Sanchez, Sebahat Dizili, Jochim Koch, Andrea Kurz.   

Abstract

PURPOSE: Perioperative hypothermia is still a common occurrence, and it can be difficult to measure a patient's core temperature accurately, especially during regional anesthesia, with placement of a laryngeal mask airway device, or postoperatively. We evaluated a new disposable double-sensor thermometer and compared the resulting temperatures with those of a distal esophageal thermometer and a bladder thermometer in patients undergoing general and regional anesthesia, respectively. Furthermore, we compared the accuracy of the thermometer between regional and general anesthesia, since forehead microcirculation might differ between the two types of anesthesia.
METHODS: We assessed core temperature in 36 general anesthesia patients and 20 patients having regional anesthesia for orthopedic surgery. The temperatures obtained using the double-sensor thermometer were compared with those obtained with the distal esophageal thermometer in the general anesthesia population and those obtained with the bladder thermometer in regional anesthesia patients.
RESULTS: In our general anesthesia patients, 90% (95% confidence interval [CI] 85 to 95) of all double-sensor values were within 0.5°C of esophageal temperatures. The average difference (bias) between the esophageal and double-sensor temperatures was -0.01°C. In patients undergoing regional anesthesia 89% (95% CI 80 to 97) of all double-sensor values were within 0.5°C of bladder temperatures. The average difference (bias) between the bladder and double-sensor temperatures was -0.13°C, limits of agreement were -0.65 to 0.40°C.
CONCLUSIONS: In a perioperative patient population undergoing general or regional anesthesia, the accuracy of the noninvasive disposable double-sensor thermometer is comparable with that of the distal esophageal and bladder thermometers in routine clinical practice. Furthermore, the sensor performed comparably in patients undergoing regional and general anesthesia.

Entities:  

Mesh:

Year:  2013        PMID: 24214518     DOI: 10.1007/s12630-013-0047-z

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  10 in total

1.  Development of local guidelines to prevent perioperative hypothermia in children: a prospective observational cohort study.

Authors:  Rehena Sultana; John C Allen; Yew Nam Siow; Choon Looi Bong; Shu Ying Lee
Journal:  Can J Anaesth       Date:  2022-09-15       Impact factor: 6.713

2.  Evaluation of the Temple Touch Pro™ noninvasive core-temperature monitoring system in 100 adults under general anesthesia: a prospective comparison with esophageal temperature.

Authors:  Anselm Bräuer; Albulena Fazliu; Ivo F Brandes; Falk Vollnhals; Rolf Grote; Matthias Menzel
Journal:  J Clin Monit Comput       Date:  2022-04-04       Impact factor: 1.977

3.  Differential cardiopulmonary monitoring system for artifact-canceled physiological tracking of athletes, workers, and COVID-19 patients.

Authors:  Hyoyoung Jeong; Jong Yoon Lee; KunHyuck Lee; Youn J Kang; Jin-Tae Kim; Raudel Avila; Andreas Tzavelis; Joohee Kim; Hanjun Ryu; Sung Soo Kwak; Jong Uk Kim; Aaron Banks; Hokyung Jang; Jan-Kai Chang; Shupeng Li; Chaithanya K Mummidisetty; Yoonseok Park; Simone Nappi; Keum San Chun; Young Joong Lee; Kyeongha Kwon; Xiaoyue Ni; Ha Uk Chung; Haiwen Luan; Jae-Hwan Kim; Changsheng Wu; Shuai Xu; Anthony Banks; Arun Jayaraman; Yonggang Huang; John A Rogers
Journal:  Sci Adv       Date:  2021-05-12       Impact factor: 14.136

4.  Increased core body temperature in astronauts during long-duration space missions.

Authors:  Alexander C Stahn; Andreas Werner; Oliver Opatz; Martina A Maggioni; Mathias Steinach; Victoria Weller von Ahlefeld; Alan Moore; Brian E Crucian; Scott M Smith; Sara R Zwart; Thomas Schlabs; Stefan Mendt; Tobias Trippel; Eberhard Koralewski; Jochim Koch; Alexander Choukèr; Günther Reitz; Peng Shang; Lothar Röcker; Karl A Kirsch; Hanns-Christian Gunga
Journal:  Sci Rep       Date:  2017-11-23       Impact factor: 4.379

5.  A prospective observational study testing liquid crystal phase change type thermometer placed on skin against oesophageal/pharyngeal placed thermometers in participants undergoing general anesthesia.

Authors:  G Simpson; R N Rodseth
Journal:  BMC Anesthesiol       Date:  2019-11-09       Impact factor: 2.217

6.  Accuracy of zero-heat-flux thermometry and bladder temperature measurement in critically ill patients.

Authors:  Anselm Bräuer; Albulena Fazliu; Thorsten Perl; Daniel Heise; Konrad Meissner; Ivo Florian Brandes
Journal:  Sci Rep       Date:  2020-12-10       Impact factor: 4.379

7.  Intraoperative zero-heat-flux thermometry overestimates esophageal temperature by 0.26 °C: an observational study in 100 infants and young children.

Authors:  Marcus Nemeth; Marijana Lovric; Thomas Asendorf; Anselm Bräuer; Clemens Miller
Journal:  J Clin Monit Comput       Date:  2020-10-31       Impact factor: 1.977

8.  Low Ambient Temperature Exposition Impairs the Accuracy of a Non-invasive Heat-Flux Thermometer.

Authors:  Michela Masè; Andreas Werner; Gabriel Putzer; Giovanni Avancini; Marika Falla; Hermann Brugger; Alessandro Micarelli; Giacomo Strapazzon
Journal:  Front Physiol       Date:  2022-03-04       Impact factor: 4.566

9.  Comparison of zero heat flux and double sensor thermometers during spinal anaesthesia: a prospective observational study.

Authors:  Sirkka-Liisa Lauronen; Maija-Liisa Kalliomäki; Jarkko Kalliovalkama; Antti Aho; Heini Huhtala; Arvi M Yli-Hankala; Marja-Tellervo Mäkinen
Journal:  J Clin Monit Comput       Date:  2022-01-03       Impact factor: 1.977

10.  Long-Term Bed Rest Delays the Circadian Phase of Core Body Temperature.

Authors:  Stefan Mendt; Katharina Brauns; Anika Friedl-Werner; Daniel L Belavy; Mathias Steinach; Thomas Schlabs; Andreas Werner; Hanns-Christian Gunga; Alexander C Stahn
Journal:  Front Physiol       Date:  2021-05-10       Impact factor: 4.566

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.