Literature DB >> 24214354

Low flow high-performance liquid chromatography solvent delivery system designed for tandem capillary liquid chromatography-mass spectrometry.

M T Davis1, D C Stahl, T D Lee.   

Abstract

A solvent delivery system is described that is designed to increase the efficiency of liquid chromatography-mass spectrometry (LC/MS) analyses. Gradients formed by using two low pressure syringe pumps are stored in a length of narrow bore tubing (gradient loop) mounted on a standard high pressure switching valve. The preformed gradient is pushed through the column by using a high pressure syringe pump. The system is fully automated and can be controlled with either a personal computer or the mass spectrometer data system. Advantages include gradient operation without the use of split flows, pressure programed flow control for rapid sample loading and recycling to initial conditions, and a flow rate range of 0.1-20 μL/min, which is suitable for packed capillary columns 50-500 μm in diameter. The system has been used extensively for rapid molecular weight determinations of intact protein samples, as well as LC/MS and liquid chromatography-tandem mass spectrometry analyses of complex peptide mixtures.

Year:  1995        PMID: 24214354     DOI: 10.1016/1044-0305(95)00192-G

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  6 in total

1.  Analysis of peptide mixtures by capillary high performance liquid chromatography: a practical guide to small-scale separations.

Authors:  M T Davis; T D Lee
Journal:  Protein Sci       Date:  1992-07       Impact factor: 6.725

Review 2.  Bombardment mass spectrometry.

Authors:  R M Caprioli
Journal:  Anal Chem       Date:  1990-04-15       Impact factor: 6.986

3.  Electrospray interface for liquid chromatographs and mass spectrometers.

Authors:  C M Whitehouse; R N Dreyer; M Yamashita; J B Fenn
Journal:  Anal Chem       Date:  1985-03       Impact factor: 6.986

4.  Recent advances in microcolumn liquid chromatography.

Authors:  M Novotny
Journal:  Anal Chem       Date:  1988-04-15       Impact factor: 6.986

5.  Ultrasonically assisted electrospray ionization for LC/MS determination of nucleosides from a transfer RNA digest.

Authors:  J F Banks; S Shen; C M Whitehouse; J B Fenn
Journal:  Anal Chem       Date:  1994-02-01       Impact factor: 6.986

6.  Application of capillary reversed-phase high-performance liquid chromatography to high-sensitivity protein sequence analysis.

Authors:  R L Moritz; R J Simpson
Journal:  J Chromatogr       Date:  1992-05-22
  6 in total
  10 in total

1.  MoWeD, a computer program to rapidly deconvolute low resolution electrospray liquid chromatography/mass spectrometry runs to determine component molecular weights.

Authors:  J O Pearcy; T D Lee
Journal:  J Am Soc Mass Spectrom       Date:  2001-05       Impact factor: 3.109

2.  A novel interface for variable flow nanoscale LC/MS/MS for improved proteome coverage.

Authors:  Johannes P C Vissers; R Kevin Blackburn; M Arthur Moseley
Journal:  J Am Soc Mass Spectrom       Date:  2002-07       Impact factor: 3.109

3.  Functional interaction of heterogeneous nuclear ribonucleoprotein C with poliovirus RNA synthesis initiation complexes.

Authors:  Jo Ellen Brunner; Joseph H C Nguyen; Holger H Roehl; Tri V Ho; Kristine M Swiderek; Bert L Semler
Journal:  J Virol       Date:  2005-03       Impact factor: 5.103

4.  Data-controlled automation of liquid chromatography/tandem mass spectrometry analysis of peptide mixtures.

Authors:  D C Stahl; K M Swiderek; M T Davis; T D Lee
Journal:  J Am Soc Mass Spectrom       Date:  1996-06       Impact factor: 3.109

5.  Development of a 45kpsi ultrahigh pressure liquid chromatography instrument for gradient separations of peptides using long microcapillary columns and sub-2μm particles.

Authors:  Kaitlin M Grinias; Justin M Godinho; Edward G Franklin; Jordan T Stobaugh; James W Jorgenson
Journal:  J Chromatogr A       Date:  2016-09-26       Impact factor: 4.759

6.  Hepatitis A virus capsid protein VP1 has a heterogeneous C terminus.

Authors:  J Graff; O C Richards; K M Swiderek; M T Davis; F Rusnak; S A Harmon; X Y Jia; D F Summers; E Ehrenfeld
Journal:  J Virol       Date:  1999-07       Impact factor: 5.103

7.  On the collision-activated fragmentation of proferrioxamines: Evidence for a succinimide-mediated mechanism.

Authors:  G J Feistner; L L Hsieh
Journal:  J Am Soc Mass Spectrom       Date:  1995-09       Impact factor: 3.109

8.  Profiling the Photochemical-Induced Degradation of Rat Growth Hormone with Extreme Ultra-pressure Chromatography-Mass Spectrometry Utilizing Meter-Long Microcapillary Columns Packed with Sub-2-μm Particles.

Authors:  Olivier Mozziconacci; Jordan T Stobaugh; Rupesh Bommana; Joshua Woods; Edward Franklin; James W Jorgenson; M Laird Forrest; Christian Schöneich; John F Stobaugh
Journal:  Chromatographia       Date:  2017-07-04       Impact factor: 2.044

9.  Rapid protein identification using a microscale electrospray LC/MS system on an ion trap mass spectrometer.

Authors:  M T Davis; T D Lee
Journal:  J Am Soc Mass Spectrom       Date:  1998-03       Impact factor: 3.262

10.  A Novel LC System Embeds Analytes in Pre-formed Gradients for Rapid, Ultra-robust Proteomics.

Authors:  Nicolai Bache; Philipp E Geyer; Dorte B Bekker-Jensen; Ole Hoerning; Lasse Falkenby; Peter V Treit; Sophia Doll; Igor Paron; Johannes B Müller; Florian Meier; Jesper V Olsen; Ole Vorm; Matthias Mann
Journal:  Mol Cell Proteomics       Date:  2018-08-13       Impact factor: 5.911

  10 in total