Multi-Gaussian fitting for pulse waveform using Weighted Least Squares and multi-criteria decision making method.

Lu Wang1, Lisheng Xu, Shuting Feng, Max Q-H Meng, Kuanquan Wang.   

Abstract

Analysis of pulse waveform is a low cost, non-invasive method for obtaining vital information related to the conditions of the cardiovascular system. In recent years, different Pulse Decomposition Analysis (PDA) methods have been applied to disclose the pathological mechanisms of the pulse waveform. All these methods decompose single-period pulse waveform into a constant number (such as 3, 4 or 5) of individual waves. Furthermore, those methods do not pay much attention to the estimation error of the key points in the pulse waveform. The estimation of human vascular conditions depends on the key points' positions of pulse wave. In this paper, we propose a Multi-Gaussian (MG) model to fit real pulse waveforms using an adaptive number (4 or 5 in our study) of Gaussian waves. The unknown parameters in the MG model are estimated by the Weighted Least Squares (WLS) method and the optimized weight values corresponding to different sampling points are selected by using the Multi-Criteria Decision Making (MCDM) method. Performance of the MG model and the WLS method has been evaluated by fitting 150 real pulse waveforms of five different types. The resulting Normalized Root Mean Square Error (NRMSE) was less than 2.0% and the estimation accuracy for the key points was satisfactory, demonstrating that our proposed method is effective in compressing, synthesizing and analyzing pulse waveforms.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Multi-Gaussian model; Multi-criteria decision making; Photoplethysmography; Pulse decomposition analysis; Pulse waveform

Mesh:

Year:  2013        PMID: 24209911     DOI: 10.1016/j.compbiomed.2013.08.004

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  9 in total

Review 1.  Pulse Waveform Analysis: Is It Ready for Prime Time?

Authors:  Bernhard Hametner; Siegfried Wassertheurer
Journal:  Curr Hypertens Rep       Date:  2017-08-11       Impact factor: 5.369

2.  Effects of blood pressure and sex on the change of wave reflection: evidence from Gaussian fitting method for radial artery pressure waveform.

Authors:  Chengyu Liu; Lina Zhao; Changchun Liu
Journal:  PLoS One       Date:  2014-11-10       Impact factor: 3.240

3.  Quantitative Comparison of the Performance of Piezoresistive, Piezoelectric, Acceleration, and Optical Pulse Wave Sensors.

Authors:  Hongju Wang; Lu Wang; Nannan Sun; Yang Yao; Liling Hao; Lisheng Xu; Stephen E Greenwald
Journal:  Front Physiol       Date:  2020-01-14       Impact factor: 4.566

4.  Robustness of ventilation systems in the control of walking-induced indoor fluctuations: Method development and case study.

Authors:  Jianlin Ren; Junjie He; Xiangfei Kong; Hongwan Li
Journal:  Build Simul       Date:  2022-02-18       Impact factor: 4.008

5.  Acute Cardiovascular Effects of Hydrotreated Vegetable Oil Exhaust.

Authors:  Youna Marc-Derrien; Louise Gren; Katrin Dierschke; Maria Albin; Anders Gudmundsson; Aneta Wierzbicka; Frida Sandberg
Journal:  Front Physiol       Date:  2022-03-08       Impact factor: 4.566

6.  Coherence between Decomposed Components of Wrist and Finger PPG Signals by Imputing Missing Features and Resolving Ambiguous Features.

Authors:  Pei-Yun Tsai; Chiu-Hua Huang; Jia-Wei Guo; Yu-Chuan Li; An-Yeu Andy Wu; Hung-Ju Lin; Tzung-Dau Wang
Journal:  Sensors (Basel)       Date:  2021-06-24       Impact factor: 3.576

7.  Modelling arterial pressure waveforms using Gaussian functions and two-stage particle swarm optimizer.

Authors:  Chengyu Liu; Tao Zhuang; Lina Zhao; Faliang Chang; Changchun Liu; Shoushui Wei; Qiqiang Li; Dingchang Zheng
Journal:  Biomed Res Int       Date:  2014-05-20       Impact factor: 3.411

8.  Changes of Femoral Photolethysmographic Waveform Characteristics in Anesthetized Dogs with Increased Blood Pressure Induced by Epinephrine.

Authors:  Hong Tang; Chengyu Liu
Journal:  Front Physiol       Date:  2016-09-14       Impact factor: 4.566

9.  Statistical Analysis of the Consistency of HRV Analysis Using BCG or Pulse Wave Signals.

Authors:  Huiying Cui; Zhongyi Wang; Bin Yu; Fangfang Jiang; Ning Geng; Yongchun Li; Lisheng Xu; Dingchang Zheng; Biyong Zhang; Peilin Lu; Stephen E Greenwald
Journal:  Sensors (Basel)       Date:  2022-03-21       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.