Literature DB >> 24209376

Optimization of the HS-SPME-GC-IT/MS method using a central composite design for volatile carbonyl compounds determination in beers.

Nathalie Moreira1, Sónia Meireles, Tiago Brandão, Paula Guedes de Pinho.   

Abstract

An automated headspace solid-phase microextraction (HS-SPME) combined with gas chromatography and ion trap mass spectrometry detection (GC-IT/MS) was developed in order to quantify a large number of carbonyl compounds in beers. Carbonyl compounds were previously derivatized with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA). Volatile carbonyl compounds associated with staling beer aroma includes alkanals, alkenals, alkadienals, dicarbonyl compounds, Strecker aldehydes, ketones and furans. The HS-SPME was performed using a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber. The procedures were optimized for HS-SPME pre-incubation temperature and time, extraction temperature and time, and PFBHA addition. A central composite design was used in the optimization of extraction conditions and PFBHA addition. The volatile compounds showed optimal extraction incubating 5 ml of beer with 700 mg l(-1) of PFBHA for 7 min and extracted for more 20 min at 45 °C. The method was validated with regard to the linearity, repeatability, inter and intra-day precision and accuracy. The method achieved detection limits ranging from 0.003 to 0.510 µg l(-1), except for furans (1.54-3.44 µg l(-1)). The quantification limits varied from 0.010 to 1.55 µg l(-1), except for 2-furfural (4.68 µg l(-1)), 5-methyl-2-furfural (5.82 µg l(-1)) and 5-hyfroxymethylfurfural (10.4 µg l(-1)). Repeatability values of all compounds were lower than 17%. The method accuracy was satisfactory with recoveries ranging from 88% to 114%. The validated method showed to be suitable for a fast and reliable determination of main carbonyl compounds in beers.
© 2013 Published by Elsevier B.V.

Entities:  

Keywords:  Beer; Central composite design (CCD); Gas chromatography–ion trap/mass spectrometry (GC–IT/MS); Headspace solid-phase microextraction (HS-SPME); PFBHA; Volatile carbonyl compounds

Mesh:

Substances:

Year:  2013        PMID: 24209376     DOI: 10.1016/j.talanta.2013.09.027

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  Oxidative stress in microbes after exposure to iron nanoparticles: analysis of aldehydes as oxidative damage products of lipids and proteins.

Authors:  Jaroslav Semerád; Monika Moeder; Jan Filip; Martin Pivokonský; Alena Filipová; Tomáš Cajthaml
Journal:  Environ Sci Pollut Res Int       Date:  2019-10-08       Impact factor: 4.223

2.  Highly sensitive analysis of low-molecular-mass aldehydes in beverages using a hydroxylamine reagent by high-performance liquid chromatography with fluorescence detection.

Authors:  Ran Liu; Long Mao; Zhaobing Guan; Chengsheng Wang; Jing Xu; Lujie Huang; Peike Wang; Guolin Xin; Rui Hu; Chuyu Zhang; Zihan Zhao; Yawei Lin; Xiaosong Hu
Journal:  Anal Bioanal Chem       Date:  2022-05-31       Impact factor: 4.142

Review 3.  Optimizing Mass Spectrometry Analyses: A Tailored Review on the Utility of Design of Experiments.

Authors:  Elizabeth S Hecht; Ann L Oberg; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2016-03-07       Impact factor: 3.109

4.  Multiple responses optimization in the development of a headspace gas chromatography method for the determination of residual solvents in pharmaceuticals.

Authors:  Carla M Teglia; Milagros Montemurro; María M De Zan; María S Cámara
Journal:  J Pharm Anal       Date:  2015-03-09

5.  Assessment of Staling Aldehydes in Lager Beer under Maritime Transport and Storage Conditions.

Authors:  Dayana Aguiar; Ana C Pereira; José C Marques
Journal:  Molecules       Date:  2022-01-18       Impact factor: 4.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.