Literature DB >> 24209368

Simultaneous determination of nanomolar nitrite and nitrate in seawater using reverse flow injection analysis coupled with a long path length liquid waveguide capillary cell.

Sichao Feng1, Min Zhang, Yongming Huang, Dongxing Yuan, Yong Zhu.   

Abstract

A reverse flow injection analysis (rFIA) method coupled with 1m liquid waveguide capillary cell and spectrophotometric detection for simultaneous determination of nanomolar nitrite and nitrate in seawater was developed. The design of two analytical channels sharing the same detection system in the proposed method allowed the analysis of both nitrite and nitrate with single sample injection. Different strategies of reagent injection were investigated to obtain a higher sensitivity and a better peak shape. A dual-wavelength detection mode was chosen to eliminate the light source shifting and sample matrix interference. Experimental parameters were optimized based on a univariate experimental design and the matrix effect from seawater was preliminarily investigated. The proposed method had high sensitivity with detection limit of 0.6 nmol L(-1) for both nitrite and nitrate. The linearity was 2-500 nmol L(-1) for both analytes, and the upper limit could be extended by choosing a lower sensitivity detection wavelength. The analytical results of 26 surface seawater samples obtained with the proposed method showed good agreement with those using a reference method operated using an automated segmented flow analyzer. The proposed method could greatly minimize the trouble introduced by bubbles in the segmented flow analyzer. It also had the advantages of high precision and high sample throughput (nitrite and nitrate detected in triplicate; 5 h(-1)). Compared to normal flow injection analysis, the rFIA method is superior due to its lower reagent consumption, less dispersion of sample, as well as higher sensitivity.
© 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Liquid waveguide capillary cell; Nanomolar nitrite and nitrate; Reverse flow injection analysis; Seawater

Mesh:

Substances:

Year:  2013        PMID: 24209368     DOI: 10.1016/j.talanta.2013.09.042

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Spectrophotometric determination of nitrate in small volume of seawater samples using a simple resorcinol method.

Authors:  Lianghui Wang; Kunning Lin; Huige Guo; Yuanbiao Zhang
Journal:  Anal Bioanal Chem       Date:  2022-06-01       Impact factor: 4.478

Review 2.  Flow-Injection Methods in Water Analysis-Recent Developments.

Authors:  Marek Trojanowicz; Marta Pyszynska
Journal:  Molecules       Date:  2022-02-19       Impact factor: 4.411

3.  A rapid and high-throughput microplate spectrophotometric method for field measurement of nitrate in seawater and freshwater.

Authors:  Jiapeng Wu; Yiguo Hong; Fengjie Guan; Yan Wang; Yehui Tan; Weizhong Yue; Meilin Wu; Liying Bin; Jiaping Wang; Jiali Wen
Journal:  Sci Rep       Date:  2016-02-01       Impact factor: 4.379

4.  Ultrasensitive Electrochemical Sensor Based on Polyelectrolyte Composite Film Decorated Glassy Carbon Electrode for Detection of Nitrite in Curing Food at Sub-Micromolar Level.

Authors:  Jingheng Ning; Xin Luo; Min Wang; Jiaojiao Li; Donglin Liu; Hou Rong; Donger Chen; Jianhui Wang
Journal:  Molecules       Date:  2018-10-09       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.