Prospective evaluation of distal radius fractures treated with variable-angle volar locking plates.

John R Fowler1, Asif M Ilyas.   

Abstract

PURPOSE: To evaluate the radiographic, objective (range of motion and grip strength), and subjective outcomes of variable-angle volar locking plate (VAVLP) fixation for unstable distal radius fractures.
METHODS: Over a 12-month period, we prospectively evaluated 39 consecutive distal radius fractures treated operatively with VAVLPs. Surgical exposure, fracture reduction, plate application, and postoperative rehabilitation were uniformly performed. Clinical outcome and radiographic measures, with a minimum follow-up of 12 months, were obtained.
RESULTS: Final follow-up data were available in 37 patients (26 females and 11 males) with average age of 57 years (range, 16-89 y). The average follow-up time was 14 months (range, 12-22 mo). At final evaluation, average volar tilt was 3°, average radial inclination was 21°, average radial height was 12 mm, and average ulnar variance was -0.2 mm. There was no statistical difference between first postoperative and 1-year follow-up radiographs for any of the measured variables, although there were 4 cases of loss of volar tilt. Average Disabilities of the Arm, Shoulder, and Hand score was 6 and average visual analog scale pain score was 0.3. Mean grip strength at 1 year was 96% of the contralateral side. There was 1 case of variable-angle locking screw loosening and 1 case of extensor tenosynovitis requiring hardware removal. There were no tendon ruptures.
CONCLUSIONS: The VAVLP fixation restored and maintained acceptable reduction in all patients in this series with a complication rate comparable to standard volar fixed-angle locking plates. Treatment of unstable distal radius fractures with a VAVLP resulted in excellent clinical outcomes at 1-year follow-up. However, use of the VAVLP risks soft tissue irritation, hardware failure, and loss of fracture reduction. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.
Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Distal radius; variable angle; volar locking plate

Mesh:

Year:  2013        PMID: 24206983     DOI: 10.1016/j.jhsa.2013.08.116

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  8 in total

1.  Unstable Distal Radius Fractures Treated by Volar Locking Anatomical Plates.

Authors:  Anto Jose; Shishir Murugharaj Suranigi; Pascal Noel Deniese; Abey Thomas Babu; Kanagasabai Rengasamy; Syed Najimudeen
Journal:  J Clin Diagn Res       Date:  2017-01-01

2.  Complications of Volar Plating of Distal Radius Fractures: A Systematic Review.

Authors:  Todd H Alter; Kristin Sandrowski; Gregory Gallant; Moody Kwok; Asif M Ilyas
Journal:  J Wrist Surg       Date:  2018-08-13

3.  Radial Plate Fixation: A Novel Technique for Distal Radius Fractures.

Authors:  Jeffrey D Hoffmann; Jeremy Stewart; Nicholas Kusnezov; John Dunn; Miguel Pirela-Cruz
Journal:  Hand (N Y)       Date:  2016-10-22

4.  Management of Unstable Distal Radius Fractures: A Survey of Hand Surgeons.

Authors:  Ara A Salibian; Karl C Bruckman; Jonathan M Bekisz; Joshua Mirrer; Vishal D Thanik; Jacques H Hacquebord
Journal:  J Wrist Surg       Date:  2018-11-16

5.  Early functional postoperative therapy of distal radius fracture with a dynamic orthosis: results of a prospective randomized cross-over comparative study.

Authors:  Fabian M Stuby; Stefan Döbele; Susanne-Dorothea Schäffer; Simon Mueller; Atesch Ateschrang; Matthias Baumann; Derek Zieker
Journal:  PLoS One       Date:  2015-03-30       Impact factor: 3.240

6.  The influence of distal screw length on the primary stability of volar plate osteosynthesis--a biomechanical study.

Authors:  Sebastian F Baumbach; Alexander Synek; Hannes Traxler; Wolf Mutschler; Dieter Pahr; Yan Chevalier
Journal:  J Orthop Surg Res       Date:  2015-09-08       Impact factor: 2.359

7.  The efficacy of using 3D printing models in the treatment of fractures: a randomised clinical trial.

Authors:  Chunhui Chen; Leyi Cai; Wenhao Zheng; Jianshun Wang; Xiaoshan Guo; Hua Chen
Journal:  BMC Musculoskelet Disord       Date:  2019-02-08       Impact factor: 2.362

8.  Lasso loop technique using bioabsorbable thread to treat intra-articular distal radius fracture.

Authors:  Yoshio Kaji; Konosuke Yamaguchi; Yumi Nomura; Kunihiko Oka; Masashi Shimamura; Shohei Kawakami; Tetsuji Yamamoto
Journal:  Medicine (Baltimore)       Date:  2021-11-24       Impact factor: 1.817