A mathematical study of sample modulation at a membrane inlet mass spectrometer-Potential application in analysis of mixtures.

F L Overney1, C G Enke.   

Abstract

An ANSI C program that simulates the diffusion profiles of sample modulation at a membrane inlet system has been developed to study the characteristics of modulated diffusion profiles. The program produces concentration profiles within the membrane and flux values at the exit side of the membrane as a function of time. Sample concentration on the inlet side can be switched between zero and an arbitrary value with a square or asymmetric cycle. Achievement of steady-state diffusion between alternations is not required. With this computer simulation, the flux profiles of analytes through a membrane inlet have been studied as a function of diffusion coefficient, modulation frequency, and concentration. The amplitude, shape, and time lag or phase angle of the flux profile are shown to be related directly to analyte concentration and diffusivity. A method that involves a set of linear equations is proposed to resolve mixtures of diffusing analytes based on differences in the time dependence of their flux profiles.

Year:  1996        PMID: 24202799     DOI: 10.1016/1044-0305(95)00622-2

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  1 in total

1.  The effects of air and helium on the performance of the ion trap detector when used for real-time monitoring of some atmospheric pollutants.

Authors:  D Cameron; P H Hemberger; J E Alarid; C P Leibman; J D Williams
Journal:  J Am Soc Mass Spectrom       Date:  1993-10       Impact factor: 3.109

  1 in total
  3 in total

1.  Utilization of a multimembrane inlet and a cyclic sudden sampling introduction mode in membrane inlet mass spectrometry.

Authors:  O S Viktorova; V T Kogan; S A Manninen; T Kotiaho; R A Ketola; B M Dubenskii; S P Parinov; O V Smirnov
Journal:  J Am Soc Mass Spectrom       Date:  2004-06       Impact factor: 3.109

2.  A field-portable membrane introduction mass spectrometer for real-time quantitation and spatial mapping of atmospheric and aqueous contaminants.

Authors:  Ryan J Bell; Nicholas G Davey; Morten Martinsen; Christian Collin-Hansen; Erik T Krogh; Christopher G Gill
Journal:  J Am Soc Mass Spectrom       Date:  2014-12-05       Impact factor: 3.109

3.  Development of multi-membrane near-infrared diode mass spectrometer for field analysis of aromatic hydrocarbons.

Authors:  Phillip M Mach; Kenneth C Wright; Guido F Verbeck
Journal:  J Am Soc Mass Spectrom       Date:  2014-12-16       Impact factor: 3.109