Literature DB >> 24199954

Bipolar-power-transistor-based limiter for high frequency ultrasound imaging systems.

Hojong Choi1, Hao-Chung Yang2, K Kirk Shung2.   

Abstract

High performance limiters are described in this paper for applications in high frequency ultrasound imaging systems. Limiters protect the ultrasound receiver from the high voltage (HV) spikes produced by the transmitter. We present a new bipolar power transistor (BPT) configuration and compare its design and performance to a diode limiter used in traditional ultrasound research and one commercially available limiter. Limiter performance depends greatly on the insertion loss (IL), total harmonic distortion (THD) and response time (RT), each of which will be evaluated in all the limiters. The results indicated that, compared with commercial limiter, BPT-based limiter had less IL (-7.7 dB), THD (-74.6 dB) and lower RT (43 ns) at 100 MHz. To evaluate the capability of these limiters, they were connected to a 100 MHz single element transducer and a two-way pulse-echo test was performed. It was found that the -6 dB bandwidth and sensitivity of the transducer using BPT-based limiter were better than those of the commercial limiter by 22% and 140%, respectively. Compared to the commercial limiter, BPT-based limiter is shown to be capable of minimizing signal attenuation, RT and THD at high frequencies and is thus suited for high frequency ultrasound applications.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bipolar power transistor; Limiter; Ultrasonic transducer

Mesh:

Year:  2013        PMID: 24199954      PMCID: PMC4018197          DOI: 10.1016/j.ultras.2013.10.010

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  4 in total

1.  Novel transmit protection scheme for ultrasound systems.

Authors:  Michael I Fuller; Travis N Blalock; John A Hossack; William F Walker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-01       Impact factor: 2.725

2.  Development of a 35-MHz piezo-composite ultrasound array for medical imaging.

Authors:  Jonathan M Cannata; Jay A Williams; Qifa Zhou; Timothy A Ritter; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-01       Impact factor: 2.725

3.  High-frequency ultrasound annular array imaging. Part II: digital beamformer design and imaging.

Authors:  Chang-Hong Hu; Kevin A Snook; Pei-Jie Cao; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-02       Impact factor: 2.725

4.  Development of integrated preamplifier for high-frequency ultrasonic transducers and low-power handheld receiver.

Authors:  Hojong Choi; Xiang Li; Sien-Ting Lau; ChangHong Hu; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-12       Impact factor: 2.725

  4 in total
  3 in total

1.  Power Amplifier Linearizer for High Frequency Medical Ultrasound Applications.

Authors:  Hojong Choi; Hayong Jung; K Kirk Shung
Journal:  J Med Biol Eng       Date:  2015-04-28       Impact factor: 1.553

2.  Novel dual-resistor-diode limiter circuit structures for high-voltage reliable ultrasound receiver systems.

Authors:  Hojong Choi
Journal:  Technol Health Care       Date:  2022       Impact factor: 1.205

3.  Improvement of Ultrasonic Pulse Generator for Automatic Pipeline Inspection.

Authors:  Noé Amir Rodríguez-Olivares; José Vicente Cruz-Cruz; Alejandro Gómez-Hernández; Rodrigo Hernández-Alvarado; Luciano Nava-Balanzar; Tomás Salgado-Jiménez; Jorge Alberto Soto-Cajiga
Journal:  Sensors (Basel)       Date:  2018-09-05       Impact factor: 3.576

  3 in total