Literature DB >> 24199942

Electron-transfer mediator for a NAD-glucose dehydrogenase-based glucose sensor.

Dong-Min Kim1, Min-yeong Kim, Sanapalli S Reddy, Jaegeol Cho, Chul-ho Cho, Suntae Jung, Yoon-Bo Shim.   

Abstract

A new electron-transfer mediator, 5-[2,5-di (thiophen-2-yl)-1H-pyrrol-1-yl]-1,10-phenanthroline iron(III) chloride (FePhenTPy) oriented to the nicotinamide adenine dinucleotide-dependent-glucose dehydrogenase (NAD-GDH) system was synthesized through a Paal-Knorr condensation reaction. The structure of the mediator was confirmed by Fourier-transform infrared spectroscopy, proton and carbon nucler magnetic resonance spectroscopy, and mass spectroscopy, and its electron-transfer characteristic for a glucose sensor was investigated using voltammetry and impedance spectroscopy. A disposable amperometric glucose sensor with NAD-GDH was constructed with FePhenTPy as an electron-transfer mediator on a screen printed carbon electrode (SPCE) and its performance was evaluated, where the addition of reduces graphene oxide (RGO) to the mediator showed the enhanced sensor performance. The experimental parameters to affect the analytical performance and the stability of the proposed glucose sensor were optimized, and the sensor exhibited a dynamic range between 30 mg/dL and 600 mg/dL with the detection limit of 12.02 ± 0.6 mg/dL. In the real sample experiments, the interference effects by acetaminophen, ascorbic acid, dopamine, uric acid, caffeine, and other monosaccharides (fructose, lactose, mannose, and xylose) were completely avoided through coating the sensor surface with the Nafion film containing lead(IV) acetate. The reliability of proposed glucose sensor was evaluated by the determination of glucose in artificial blood and human whole blood samples.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24199942     DOI: 10.1021/ac403217t

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Rational design of binder-free noble metal/metal oxide arrays with nanocauliflower structure for wide linear range nonenzymatic glucose detection.

Authors:  Zhenzhen Li; Yanmei Xin; Zhonghai Zhang; Hongjun Wu; Peng Wang
Journal:  Sci Rep       Date:  2015-06-12       Impact factor: 4.379

Review 2.  Enzyme Biosensors for Biomedical Applications: Strategies for Safeguarding Analytical Performances in Biological Fluids.

Authors:  Gaia Rocchitta; Angela Spanu; Sergio Babudieri; Gavinella Latte; Giordano Madeddu; Grazia Galleri; Susanna Nuvoli; Paola Bagella; Maria Ilaria Demartis; Vito Fiore; Roberto Manetti; Pier Andrea Serra
Journal:  Sensors (Basel)       Date:  2016-05-30       Impact factor: 3.576

3.  Inorganic iron-sulfur clusters enhance electron transport when used for wiring the NAD-glucose dehydrogenase based redox system.

Authors:  Aishwarya Mahadevan; Sandun Fernando
Journal:  Mikrochim Acta       Date:  2018-06-26       Impact factor: 5.833

4.  Reusable, Non-Invasive, and Ultrafast Radio Frequency Biosensor Based on Optimized Integrated Passive Device Fabrication Process for Quantitative Detection of Glucose Levels.

Authors:  Yang Li; Zhao Yao; Wenjing Yue; Chunwei Zhang; Song Gao; Cong Wang
Journal:  Sensors (Basel)       Date:  2020-03-11       Impact factor: 3.576

5.  Development of a Sensitive Self-Powered Glucose Biosensor Based on an Enzymatic Biofuel Cell.

Authors:  Kantapat Chansaenpak; Anyanee Kamkaew; Sireerat Lisnund; Pannaporn Prachai; Patipat Ratwirunkit; Thitichaya Jingpho; Vincent Blay; Piyanut Pinyou
Journal:  Biosensors (Basel)       Date:  2021-01-07

6.  2D metal azolate framework as nanozyme for amperometric detection of glucose at physiological pH and alkaline medium.

Authors:  Muhammad Adeel; Vincenzo Canzonieri; Salvatore Daniele; Alberto Vomiero; Flavio Rizzolio; Md Mahbubur Rahman
Journal:  Mikrochim Acta       Date:  2021-02-10       Impact factor: 5.833

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.