Literature DB >> 24197726

Further studies using X-ray fluorescence to sample lead contaminated carpeted surfaces.

B N Bero1, M C von Braun, C R Knowles, J E Hammel.   

Abstract

The sampling of carpeted surfaces to test for lead contamination primarily focuses upon vacuum techniques. Vacuum sampling techniques, however, require time-consuming, expensive laboratory analysis of the dusts obtained and are unable to determine total lead load on the carpet. X-ray fluorescence (XRF) analysis is an on-site, inexpensive, non-destructive, quick technique for predicting metals levels in a variety of media, such as water, soil, filter paper and painted surfaces. A 1992 study of the feasibility of XRF to analyze for lead and soil loadings on carpeted surfaces indicated that XRF can detect lead at a low enough level to warrant further study. This paper expands this earlier study and developes lead and soil loading calibration curves for three different carpet types based upon XRF lead L-beta peak areas and XRF iron and barium K-alpha peak and background areas. Results indicate that variation in the data can be reduced through modifications of the XRF analysis technique, thus reducing the statistically determined detection level, and that carpet type does affect the calibration. Detection levels of approximately 70 mg/m(2) for lead and 5 g/m(2) for soil were obtained. Overall, good agreement was found between results of this study and the earlier one. XRF shows excellent potential for quantitative analysis of lead on carpeted surfaces.

Entities:  

Year:  1995        PMID: 24197726     DOI: 10.1007/BF00546785

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  3 in total

1.  Children's blood lead and exposure to lead in household dust and water--a basis for an environmental standard for lead in dust.

Authors:  D P Laxen; G M Raab; M Fulton
Journal:  Sci Total Environ       Date:  1987-10       Impact factor: 7.963

2.  Clean-up of lead in household carpet and floor dust.

Authors:  L Ewers; S Clark; W Menrath; P Succop; R Bornschein
Journal:  Am Ind Hyg Assoc J       Date:  1994-07

3.  The use of X-ray fluorescence to detect lead contamination of carpeted surfaces.

Authors:  B N Bero; M C Von Braun; C R Knowles; J E Hammel
Journal:  Environ Monit Assess       Date:  1993-08       Impact factor: 2.513

  3 in total
  1 in total

1.  A robust X-ray fluorescence technique for multielemental analysis of solid samples.

Authors:  Nikolaos Kallithrakas-Kontos; Spyros Foteinis; Katherine Paigniotaki; Minos Papadogiannakis
Journal:  Environ Monit Assess       Date:  2016-01-27       Impact factor: 2.513

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.