Literature DB >> 24195621

The efficacy of the self-paced V̇O2max test to measure maximal oxygen uptake in treadmill running.

Alexis R Mauger1, Alan J Metcalfe, Lee Taylor, Paul C Castle.   

Abstract

The novel self-paced, cycle-based maximal oxygen uptake (V̇O2max) test (SPV) has been shown to produce higher V̇O2max values than standard graded exercise test (GXT) protocols. This study sought to ascertain whether these observations would also be apparent in a self-paced, treadmill-based test design. Fourteen trained male runners performed a standard GXT on a motorised treadmill and a self-paced V̇O2max test on a nonmotorised treadmill in a counter-balanced design. The GXT included a plateau verification and was designed to last between 8 and 12 min. The self-paced test included 5 × 2 min stages and allowed participants to set their own running speed based on fixed increments in rating of perceived exertion. Significantly higher V̇O2max values (t[13] = 3.71, p = 0.003) were achieved in the self-paced test (64.4 ± 7.3 mL · kg(-1) · min(-1)) compared with the GXT (61.3 ± 7.3 mL · kg(-1) · min(-1)), and 13 of the 14 participants achieved the same or higher V̇O2max values in the self-paced test. Higher (p = 0.01) maximum heart rates were observed in the GXT (191 ± 10 beats · min(-1) vs. 187 ± 7 beats · min(-1)), but no differences were observed in any other recorded variables. The self-paced V̇O2max test may provide a more valid means of measuring V̇O2max than the GXT and suggests that a V̇O2 plateau during a GXT does not always signify achievement of a definitive V̇O2max. These results provide further support that self-paced V̇O2max testing produces higher values for maximal oxygen uptake.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24195621     DOI: 10.1139/apnm-2012-0384

Source DB:  PubMed          Journal:  Appl Physiol Nutr Metab        ISSN: 1715-5312            Impact factor:   2.665


  15 in total

1.  Inconsistent approach to evaluating studies and selective interpretation of data reveals lack of objectivity and undermines repeated attempts to discredit SPV.

Authors:  Lauren A Jenkins; Alexis R Mauger; James G Hopker
Journal:  Eur J Appl Physiol       Date:  2017-03-27       Impact factor: 3.078

2.  Statistical model ignores 'age', products of peak Q and a-vΟ₂ difference greatly exceed V̇Ο₂max and different ergometers confound validity.

Authors:  Roger Eston; Adrian Esterman
Journal:  Eur J Appl Physiol       Date:  2017-02-28       Impact factor: 3.078

3.  Data inconsistencies and inaccuracies combined with methodological problems render physiological interpretation suspect.

Authors:  David C Poole
Journal:  Eur J Appl Physiol       Date:  2017-03-04       Impact factor: 3.078

4.  Ramp-incremented and RPE-clamped test protocols elicit similar VO2max values in trained cyclists.

Authors:  Allison M Straub; Adrian W Midgley; Gerald S Zavorsky; Angela R Hillman
Journal:  Eur J Appl Physiol       Date:  2014-04-29       Impact factor: 3.078

5.  Modality determines VO2max achieved in self-paced exercise tests: validation with the Bruce protocol.

Authors:  Nicholas J Hanson; Cory M Scheadler; Taylor L Lee; Noah C Neuenfeldt; Timothy J Michael; Michael G Miller
Journal:  Eur J Appl Physiol       Date:  2016-05-05       Impact factor: 3.078

6.  Pacing strategy during the final stage of a self-paced V̇O₂max (SPV) test does not affect maximal oxygen uptake.

Authors:  Nicholas J Hanson; Carter R Reid; Kaitlin M Cornwell; Taylor L Lee; Cory M Scheadler
Journal:  Eur J Appl Physiol       Date:  2017-06-05       Impact factor: 3.078

Review 7.  Submaximal, Perceptually Regulated Exercise Testing Predicts Maximal Oxygen Uptake: A Meta-Analysis Study.

Authors:  Jeremy Coquart; Montassar Tabben; Abdulaziz Farooq; Claire Tourny; Roger Eston
Journal:  Sports Med       Date:  2016-06       Impact factor: 11.136

8.  Intraspecific variation in aerobic and anaerobic locomotion: gilthead sea bream (Sparus aurata) and Trinidadian guppy (Poecilia reticulata) do not exhibit a trade-off between maximum sustained swimming speed and minimum cost of transport.

Authors:  Jon C Svendsen; Bjørn Tirsgaard; Gerardo A Cordero; John F Steffensen
Journal:  Front Physiol       Date:  2015-02-17       Impact factor: 4.566

9.  The effect of trial familiarisation on the validity and reproducibility of a field-based self-paced VO2max test.

Authors:  W Lim; D Lambrick; A R Mauger; B Woolley; J Faulkner
Journal:  Biol Sport       Date:  2016-07-02       Impact factor: 2.806

Review 10.  Graded Exercise Testing Protocols for the Determination of VO2max: Historical Perspectives, Progress, and Future Considerations.

Authors:  Nicholas M Beltz; Ann L Gibson; Jeffrey M Janot; Len Kravitz; Christine M Mermier; Lance C Dalleck
Journal:  J Sports Med (Hindawi Publ Corp)       Date:  2016-12-25
View more