Literature DB >> 24193277

Osseointegration of hydroxyapatite-coated, polyethylene-intruded and uncoated, sandblastered pure titanium implants in an infected implantation site. An experimental investigation in miniature pigs.

A Wilke1, J Orth, M Kraft, P Griss.   

Abstract

The authors studied the ingrowth dynamics of bone tissue into the pores of Hydroxyapatite-coated and uncoated wire-meshs of pure titanium in an infected implantation site. Samples of the tested materials were implanted into femora of 15 adult Göttingen minipigs. Just before implantation they were contaminated with Staphylococcus aureus. The animals were killed after 4, 8, 12 and 24 weeks. Undecalcified groundsections of bone tissue were prepared (app. 100 µm) for comparative histological evaluation. The HA-coated implants demonstrated advanced new bone formation after 4 weeks and nearly complete osseointegration after 12 weeks although all samples showed gross and histological signs of infection. Comparable reactions to the uncoated implants could only be observed after 24 weeks. Signs of degradation of the Hydroxyapatite-coating could be seen in contact to soft tissue and were more extensive compared to the behaviour in an uninfected site.

Entities:  

Year:  1995        PMID: 24193277     DOI: 10.1007/BF02716218

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  8 in total

1.  [Biological behavior of the hydroxyapatite ceramic coating on the femur shaft of a titanium endoprosthesis--initial histologic evaluation of a human explant].

Authors:  J F Osborn
Journal:  Biomed Tech (Berl)       Date:  1987 Jul-Aug       Impact factor: 1.411

Review 2.  [Bioactive materials. A critical review].

Authors:  M Ungethüm; U Fink
Journal:  Z Orthop Ihre Grenzgeb       Date:  1988-12

3.  [Histology of the implant-bone interface in cemented and uncemented endoprostheses].

Authors:  T Herren; W Remagen; R Schenk
Journal:  Orthopade       Date:  1987-06       Impact factor: 1.087

4.  Comparative histocompatibility testing of seven calcium phosphate ceramics.

Authors:  M Winter; P Griss; K de Groot; H Tagai; G Heimke; H J von Dijk; K Sawai
Journal:  Biomaterials       Date:  1981-07       Impact factor: 12.479

5.  The biological performance of calcium phosphate ceramics in an infected implantation site: I. Biological performance of hydroxyapatite during Staphylococcus aureus infection.

Authors:  C A van Blitterswijk; J J Grote; K de Groot; W T Daems; W Kuijpers
Journal:  J Biomed Mater Res       Date:  1986-09

6.  The biological performance of calcium phosphate ceramics in an infected implantation site: II. Biological evaluation of hydroxyapatite during short-term infection.

Authors:  C A van Blitterswijk; D Bakker; J J Grote; W T Daems
Journal:  J Biomed Mater Res       Date:  1986-09

7.  [Hydroxyapatite ceramic coatings for anchoring components of hip joint prostheses (technical aspects)].

Authors:  E Dörre
Journal:  Biomed Tech (Berl)       Date:  1989-03       Impact factor: 1.411

8.  Revision with gentamicin-impregnated cement for deep infections in total hip arthroplasties.

Authors:  A S Carlsson; G Josefsson; L Lindberg
Journal:  J Bone Joint Surg Am       Date:  1978-12       Impact factor: 5.284

  8 in total
  1 in total

1.  The infected orthopaedic implant. An animal model to study the mechanisms of haematogenous infection of cementless implant materials.

Authors:  H C Vogelyl; W J Dhertl; A Fleer; A J Verboutl
Journal:  Eur J Orthop Surg Traumatol       Date:  1996-05
  1 in total