Literature DB >> 24193151

PDMS based coplanar microfluidic channels for the surface reduction of oxidized Galinstan.

Guangyong Li1, Mitesh Parmar, Daeyoung Kim, Jeong-Bong J B Lee, Dong-Weon Lee.   

Abstract

Galinstan has the potential to replace mercury - one of the most popular liquid metals. However, the easy oxidation of Galinstan restricts wide applicability of the material. In this paper, we report an effective reduction method for the oxidized Galinstan using gas permeable PDMS (polydimethlysiloxane)-based microfluidic channel. The complete study is divided into two parts - reduction of Galinstan oxide and behavior of reduced Galinstan oxide in a microfluidic channel. The reduction of Galinstan oxide is discussed on the basis of static as well as dynamic angles. The contact angle analyses help to find the extent of reduction by wetting characteristics of the oxide, to optimize PDMS thickness and to select suitable hydrochloric acid (HCl) concentration. The highest advancing angle of 155° and receding angle of 136° is achieved with 200 μm thick PDMS film and 37 wt% (weight percent) HCl solution. The behavior of reduced Galinstan oxide is analyzed in PDMS-based coplanar microfluidic channels fabricated using a simple micromolding technique. Galinstan in the microfluidic channel is surrounded by another coplanar channel filled with HCl solution. Due to the excellent permeability of PDMS, HCl permeates through the PDMS wall between the two channels (interchannel PDMS wall) and achieves a continuous chemical reaction with oxidized Galinstan. A Lab VIEW controlled syringe pump is used for observing the behavior of HCl treated Galinstan in the microfluidic channel. Further optimization of the microfluidic device has been conducted to minimize the reoxidation of reduced Galinstan oxide in the microfluidic channel.

Entities:  

Year:  2013        PMID: 24193151     DOI: 10.1039/c3lc50952d

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  4 in total

1.  Highly stable liquid metal-based pressure sensor integrated with a microfluidic channel.

Authors:  Taekeon Jung; Sung Yang
Journal:  Sensors (Basel)       Date:  2015-05-21       Impact factor: 3.576

Review 2.  Recent Advancements in Liquid Metal Flexible Printed Electronics: Properties, Technologies, and Applications.

Authors:  Xuelin Wang; Jing Liu
Journal:  Micromachines (Basel)       Date:  2016-11-30       Impact factor: 2.891

3.  Generation of liquid metal double emulsion droplets using gravity-induced microfluidics.

Authors:  Qiyue Fan; Yaohao Guo; Shuangliang Zhao; Bo Bao
Journal:  RSC Adv       Date:  2022-07-19       Impact factor: 4.036

4.  Robust Impact Effect and Super-Lyophobic Reduced Galinstan on Polymers Applied for Energy Harvester.

Authors:  Husheng Chen; Shilong Hu; Yuan Jin; Aibing Zhang; Licheng Hua; Jianke Du; Guangyong Li
Journal:  Polymers (Basel)       Date:  2022-09-02       Impact factor: 4.967

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.