Literature DB >> 24192798

Temporal trends in quality of care among recipients of implantable cardioverter-defibrillators: insights from the National Cardiovascular Data Registry.

John A Dodson1, Rachel Lampert, Yongfei Wang, Stephen C Hammill, Paul Varosy, Jeptha P Curtis.   

Abstract

BACKGROUND: The ICD Registry was established in 2006 in part to measure quality of care in patients undergoing implantation of implantable cardioverter-defibrillators (ICDs); however, whether outcomes have improved since initiation of the registry is unknown. Our objective was to examine changes over time in 3 quality metrics available from the registry. METHODS AND
RESULTS: We performed an observational study of 367 153 patients who received new ICD implants from April 2006 to March 2010. Three quality metrics were selected: Adverse events (in-hospital complications or mortality), optimal medical therapy (OMT), and cardiac resynchronization therapy (CRT). OMT was defined as prescription of β-blocker and either angiotensin-converting enzyme inhibitor or angiotensin receptor blocker in eligible patients. CRT eligibility was determined by QRS ≥120 ms, left ventricular ejection fraction ≤35%, and New York Heart Association class III/IV. Observation periods were divided into four 12-month intervals. We analyzed changes over time and used hierarchical logistic regression to adjust for potential confounders. Adverse events decreased over time (3.7% to 2.8%, P<0.001). Among eligible patients, rates of OMT and CRT increased over time (OMT: 69.0% to 74.3%, P<0.001; CRT: 80.5% to 84.2%, P<0.001). After adjustment for potential confounders, patients were significantly less likely to experience adverse events in year 4 than in year 1 (odds ratio, 0.75; 95% confidence interval, 0.71-0.79) and significantly more likely to receive OMT (odds ratio, 1.29; 95% confidence interval, 1.26-1.32) and CRT (odds ratio, 1.42; 95% confidence interval, 1.35-1.49).
CONCLUSIONS: Since initiation of the ICD Registry, adverse events have been decreasing, and rates of OMT and CRT among eligible patients have been increasing, although there is still significant room for improvement.

Entities:  

Keywords:  cardioverter-defibrillators, implantable; electrophysiology; quality of health care; registries

Mesh:

Year:  2013        PMID: 24192798      PMCID: PMC3946506          DOI: 10.1161/CIRCULATIONAHA.113.003747

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  17 in total

1.  Optimal medical therapy use among patients receiving implantable cardioverter/defibrillators: insights from the National Cardiovascular Data Registry.

Authors:  Amy Leigh Miller; Yongfei Wang; Jeptha Curtis; Frederick A Masoudi; Alfred E Buxton; Tracy Y Wang
Journal:  Arch Intern Med       Date:  2011-11-14

Review 2.  Review of the registry's fourth year, incorporating lead data and pediatric ICD procedures, and use as a national performance measure.

Authors:  Stephen C Hammill; Mark S Kremers; Lynne Warner Stevenson; Paul A Heidenreich; Christine M Lang; Jeptha P Curtis; Yongfei Wang; Charles I Berul; Alan H Kadish; Sana M Al-Khatib; Ileana L Pina; Mary Norine Walsh; Michael J Mirro; Bruce D Lindsay; Matthew R Reynolds; Kathryn Pontzer; Laura Blum; Frederick Masoudi; John Rumsfeld; Ralph G Brindis
Journal:  Heart Rhythm       Date:  2010-07-18       Impact factor: 6.343

3.  Cardiac-resynchronization therapy for mild-to-moderate heart failure.

Authors:  Anthony S L Tang; George A Wells; Mario Talajic; Malcolm O Arnold; Robert Sheldon; Stuart Connolly; Stefan H Hohnloser; Graham Nichol; David H Birnie; John L Sapp; Raymond Yee; Jeffrey S Healey; Jean L Rouleau
Journal:  N Engl J Med       Date:  2010-11-14       Impact factor: 91.245

4.  The National Cardiovascular Data Registry (NCDR) Data Quality Brief: the NCDR Data Quality Program in 2012.

Authors:  John C Messenger; Kalon K L Ho; Christopher H Young; Lara E Slattery; Jasmine C Draoui; Jeptha P Curtis; Gregory J Dehmer; Frederick L Grover; Michael J Mirro; Matthew R Reynolds; Ivan C Rokos; John A Spertus; Tracy Y Wang; Stuart A Winston; John S Rumsfeld; Frederick A Masoudi
Journal:  J Am Coll Cardiol       Date:  2012-09-19       Impact factor: 24.094

5.  Pacemaker or defibrillator surgery without interruption of anticoagulation.

Authors:  David H Birnie; Jeff S Healey; George A Wells; Atul Verma; Anthony S Tang; Andrew D Krahn; Christopher S Simpson; Felix Ayala-Paredes; Benoit Coutu; Tiago L L Leiria; Vidal Essebag
Journal:  N Engl J Med       Date:  2013-05-09       Impact factor: 91.245

6.  The relation between hospital procedure volume and complications of cardioverter-defibrillator implantation from the implantable cardioverter-defibrillator registry.

Authors:  James V Freeman; Yongfei Wang; Jeptha P Curtis; Paul A Heidenreich; Mark A Hlatky
Journal:  J Am Coll Cardiol       Date:  2010-09-28       Impact factor: 24.094

7.  Implantable cardioverter-defibrillator registry risk score models for acute procedural complications or death after implantable cardioverter-defibrillator implantation.

Authors:  David E Haines; Yongfei Wang; Jeptha Curtis
Journal:  Circulation       Date:  2011-05-02       Impact factor: 29.690

8.  Prevalence and predictors of off-label use of cardiac resynchronization therapy in patients enrolled in the National Cardiovascular Data Registry Implantable Cardiac-Defibrillator Registry.

Authors:  Adam S Fein; Yongfei Wang; Jeptha P Curtis; Frederick A Masoudi; Paul D Varosy; Matthew R Reynolds
Journal:  J Am Coll Cardiol       Date:  2010-08-31       Impact factor: 24.094

9.  Characteristics of heart failure patients associated with good and poor response to cardiac resynchronization therapy: a PROSPECT (Predictors of Response to CRT) sub-analysis.

Authors:  Rutger J van Bommel; Jeroen J Bax; William T Abraham; Eugene S Chung; Luis A Pires; Luigi Tavazzi; Peter J Zimetbaum; Bart Gerritse; Nina Kristiansen; Stefano Ghio
Journal:  Eur Heart J       Date:  2009-08-30       Impact factor: 29.983

10.  Cardiac-resynchronization therapy for the prevention of heart-failure events.

Authors:  Arthur J Moss; W Jackson Hall; David S Cannom; Helmut Klein; Mary W Brown; James P Daubert; N A Mark Estes; Elyse Foster; Henry Greenberg; Steven L Higgins; Marc A Pfeffer; Scott D Solomon; David Wilber; Wojciech Zareba
Journal:  N Engl J Med       Date:  2009-09-01       Impact factor: 91.245

View more
  5 in total

Review 1.  How to study improvement interventions: a brief overview of possible study types.

Authors:  Margareth Crisóstomo Portela; Peter J Pronovost; Thomas Woodcock; Pam Carter; Mary Dixon-Woods
Journal:  BMJ Qual Saf       Date:  2015-03-25       Impact factor: 7.035

Review 2.  How to study improvement interventions: a brief overview of possible study types.

Authors:  Margareth Crisóstomo Portela; Peter J Pronovost; Thomas Woodcock; Pam Carter; Mary Dixon-Woods
Journal:  Postgrad Med J       Date:  2015-06       Impact factor: 2.401

3.  Temporal trends and long-term outcomes among recipients of cardiac resynchronization therapy with defibrillator in the United States, 2011-2015: Insights from the National Cardiovascular Data Registry.

Authors:  Douglas Darden; Pamela N Peterson; Xin Xin; Muhammad Bilal Munir; Karl E Minges; Ilan Goldenberg; Jeanne E Poole; Gregory K Feld; Ulrika Birgersdotter-Green; Jeptha P Curtis; Jonathan C Hsu
Journal:  Heart Rhythm O2       Date:  2022-04-02

4.  Geographic and Temporal Variation in Cardiac Implanted Electric Devices to Treat Heart Failure.

Authors:  Laura A Hatfield; Daniel B Kramer; Rita Volya; Matthew R Reynolds; Sharon-Lise T Normand
Journal:  J Am Heart Assoc       Date:  2016-07-28       Impact factor: 5.501

5.  Chest pain following permanent pacemaker insertion… a case of pneumopericardium due to atrial lead perforation.

Authors:  Suleman Aktaa; Kavi Fatania; Claire Gains; Hazel White
Journal:  BMJ Case Rep       Date:  2018-10-25
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.