Literature DB >> 24191994

Dynamic bowtie for fan-beam CT.

Fenglin Liu1, Ge Wang, Wenxiang Cong, Scott S Hsieh, Norbert J Pelc.   

Abstract

A bowtie is a filter used to shape an x-ray beam and equalize its flux reaching different detector channels. For development of spectral CT with energy discriminating photon-counting (EDPC) detectors, here we propose and evaluate a dynamic bowtie for performance optimization based on a patient model or a scout scan. With a mechanical rotation of a dynamic bowtie and an adaptive adjustment of an x-ray source flux, an x-ray beam intensity profile can be modulated. First, a mathematical model for dynamic bowtie filtering is established for an elliptical section in fan-beam geometry, and the contour of the optimal bowtie is derived. Then, numerical simulation is performed to compare the performance of the dynamic bowtie in the cases of an ideal phantom and a realistic cross-section relative to the counterparts without any bowtie and with a fixed bowtie respectively. Our dynamic bowtie can equalize the expected numbers of photons in the case of an ideal phantom. In practical cases, our dynamic bowtie can effectively reduce the dynamic range of detected signals inside the field of view. Although our design is optimized for an elliptical phantom, the resultant dynamic bowtie can be applied to a real fan-beam scan if the underlying cross-section can be approximated as an ellipse. Furthermore, our design methodology can be applied to specify an optimized dynamic bowtie for any cross-section of a patient, preferably using rapid prototyping technology.

Entities:  

Keywords:  Dynamic bowtie; computed tomography (CT); elliptical phantom; tube current modulation

Mesh:

Year:  2013        PMID: 24191994     DOI: 10.3233/XST-130386

Source DB:  PubMed          Journal:  J Xray Sci Technol        ISSN: 0895-3996            Impact factor:   1.535


  4 in total

1.  Control algorithms for dynamic attenuators.

Authors:  Scott S Hsieh; Norbert J Pelc
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

2.  Task-Driven Optimization of Fluence Field and Regularization for Model-Based Iterative Reconstruction in Computed Tomography.

Authors:  Grace J Gang; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  IEEE Trans Med Imaging       Date:  2017-10-16       Impact factor: 10.048

3.  Design Optimization of Spatial-Spectral Filters for Cone-Beam CT Material Decomposition.

Authors:  Matthew Tivnan; Wenying Wang; Grace Gang; J Webster Stayman
Journal:  IEEE Trans Med Imaging       Date:  2022-08-31       Impact factor: 11.037

4.  Dynamic bowtie filter for cone-beam/multi-slice CT.

Authors:  Fenglin Liu; Qingsong Yang; Wenxiang Cong; Ge Wang
Journal:  PLoS One       Date:  2014-07-22       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.