Impact of plasma of argon cleaning treatment on implant abutments in patients with a history of periodontal disease and thin biotype: radiographic results at 24-month follow-up of a RCT.

Luigi Canullo1, David Peñarrocha, Marco Clementini, Giuliano Iannello, Costanza Micarelli.   

Abstract

BACKGROUND: A lack of evidence is present in literature regarding the clinical relevance of micropollution and bacterial contamination present on customized titanium abutments following laboratory stages and steaming cleaning procedures. To preserve abutments from such pollutants, plasma of argon cleaning of customized abutments was advocated. AIM: The aim of this prospective, randomized, match-paired, triple-blinded, controlled, clinical trial is to longitudinally assess radiographical marginal bone-level changes around implants restored according to the platform switching and "one-abutment-one-time" concepts, using commercially available abutments, with and without plasma of argon cleaning treatment after customization.
MATERIALS AND METHODS: Thirty patients with thin gingival biotype, a history of periodontal disease, and in general good health received one implant in the anterior maxilla or premolar region. Patients were randomly assigned to control (abutment subjected only to usually adopted cleaning protocol by steam) and test group (abutment subjected to plasma of argon treatment). Periapical standardized digital radiographs were taken at the time of crown connection (T0), 6 (T1) and 24 months after the final restoration (T2). Average mesial-distal bone-level changes mean values with standard deviations (SD) were calculated. The Mann-Whitney U-test was selected to identify differences in bone-level changes between test and control groups.
RESULTS: An average interproximal bone loss of 0.16 mm (SD: 0.17) and 0.07 mm (SD: 0.34) was revealed in the control and test group at 6 months (T1), respectively, while after 24 months, groups showed a mean bone-level changes of 0.38 mm (SD: 0.44) and 0.11 mm (SD: 0.14), respectively. Statistically significant differences among control and test groups were found at both time points. Intergroup comparison relived absence of statistically significant difference.
CONCLUSION: Plasma-cleaning treatment of implant titanium abutments, together with platform switching and one-abutment-one-time concepts, could be favorable in terms of hard-tissue-level changes, also in critical conditions such as in patients with a history of periodontal disease, presenting thin gingival biotype.
© 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  bone resorption; cleaning; follow-up studies; glow discharge; implant abutment; plasma of argon; platform switching; surface modification

Mesh:

Substances:

Year:  2013        PMID: 24191873     DOI: 10.1111/clr.12290

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  9 in total

1.  Inhibition of bacterial growth on zirconia abutment with a helium cold atmospheric plasma jet treatment.

Authors:  Yang Yang; Miao Zheng; Yang Yang; Jing Li; Yong-Fei Su; He-Ping Li; Jian-Guo Tan
Journal:  Clin Oral Investig       Date:  2020-01-15       Impact factor: 3.573

2.  Microscopical and chemical surface characterization of CAD/CAM zircona abutments after different cleaning procedures. A qualitative analysis.

Authors:  Peter Gehrke; Astrid Tabellion; Carsten Fischer
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

3.  Interaction of titanium, zirconia and lithium disilicate with peri-implant soft tissue: study protocol for a randomized controlled trial.

Authors:  Katharina Kuhn; Heike Rudolph; Michael Graf; Matthias Moldan; Shaoxia Zhou; Martin Udart; Andrea Böhmler; Ralph G Luthardt
Journal:  Trials       Date:  2015-10-15       Impact factor: 2.279

4.  The bactericidal effect of an atmospheric-pressure plasma jet on Porphyromonas gingivalis biofilms on sandblasted and acid-etched titanium discs.

Authors:  Ji-Yoon Lee; Kyoung-Hwa Kim; Shin-Young Park; Sung-Young Yoon; Gon-Ho Kim; Yong-Moo Lee; In-Chul Rhyu; Yang-Jo Seol
Journal:  J Periodontal Implant Sci       Date:  2019-10-04       Impact factor: 2.614

5.  The efficacy of convenient cleaning methods applicable for customized abutments: an in vitro study.

Authors:  Sunjai Kim; Changhun Choi; Yunsu Cha; Jae-Seung Chang
Journal:  BMC Oral Health       Date:  2021-02-18       Impact factor: 2.757

6.  Delphi Project on the trends in Implant Dentistry in the COVID-19 era: Perspectives from Latin America.

Authors:  Marco Antonio Alarcón; Ignacio Sanz-Sánchez; Jamil Awad Shibli; Alejandro Treviño Santos; Santiago Caram; Alejandro Lanis; Paola Jiménez; Ricardo Dueñas; Ronald Torres; Jacinto Alvarado; Adrián Avendaño; Roberto Galindo; Vilma Umanzor; Mónica Shedden; Carlos Invernizzi; Caroll Yibrin; James Collins; Roberto León; Luis Contreras; Luis Bueno; Andrea López-Pacheco; Lilian Málaga-Figueroa; Mariano Sanz
Journal:  Clin Oral Implants Res       Date:  2021-03-15       Impact factor: 5.021

Review 7.  Plasma of Argon Treatment of the Implant Surface, Systematic Review of In Vitro Studies.

Authors:  Massimo Carossa; Davide Cavagnetto; Francesca Mancini; Alessandro Mosca Balma; Federico Mussano
Journal:  Biomolecules       Date:  2022-09-01

8.  Bacterial inactivation/sterilization by argon plasma treatment on contaminated titanium implant surfaces: In vitro study.

Authors:  Marco Annunziata; Luigi Canullo; Giovanna Donnarumma; Pina Caputo; Livia Nastri; Luigi Guida
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2016-01-01

Review 9.  Effects of modified abutment characteristics on peri-implant soft tissue health: A systematic review and meta-analysis.

Authors:  Ignacio Sanz-Martín; Ignacio Sanz-Sánchez; Ana Carrillo de Albornoz; Elena Figuero; Mariano Sanz
Journal:  Clin Oral Implants Res       Date:  2017-10-26       Impact factor: 5.977