Determining urea levels in exhaled breath condensate with minimal preparation steps and classic LC-MS.

Masha Pitiranggon1, Matthew S Perzanowski2, Patrick L Kinney2, Dongqun Xu3, Steven N Chillrud4, Beizhan Yan5.   

Abstract

Exhaled breath condensate (EBC) provides a relatively easy, non-invasive method for measuring biomarkers of inflammation and oxidative stress in the airways. However, the levels of these biomarkers in EBC are influenced, not only by their levels in lung lining fluid but also by the volume of water vapor that also condenses during EBC collection. For this reason, the use of a biomarker of dilution has been recommended. Urea has been proposed and utilized as a promising dilution biomarker due to its even distribution throughout the body and relatively low volatility. Current EBC urea analytical methods either are not sensitive enough, necessitating large volumes of EBC, or are labor intensive, requiring a derivatization step or other pretreatment. We report here a straightforward and reliable LC-MS approach that we developed that does not require derivatization or large sample volume (∼36 µL). An Acclaim mixed-mode hydrophilic interaction chromatography column was selected because it can produce good peak symmetry and efficiently separate urea from other polar and nonpolar compounds. To achieve a high recovery rate, a slow and incomplete evaporation method was used followed by a solvent-phase exchange. Among EBC samples collected from 28 children, urea levels were found to be highly variable, with a relative standard deviation of 234%, suggesting high variability in dilution of the lung lining fluid component of EBC. The limit of detection was found to be 0.036 µg/mL. Published by Oxford University Press [2013]. This work is written by (a) US Government employee(s) and is in the public domain in the US.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24190872      PMCID: PMC4215077          DOI: 10.1093/chromsci/bmt150

Source DB:  PubMed          Journal:  J Chromatogr Sci        ISSN: 0021-9665            Impact factor:   1.618


  33 in total

1.  A simple method for estimating respiratory solute dilution in exhaled breath condensates.

Authors:  Richard M Effros; Julie Biller; Bradley Foss; Kelly Hoagland; Marshall B Dunning; Daniel Castillo; Mark Bosbous; Feng Sun; Reza Shaker
Journal:  Am J Respir Crit Care Med       Date:  2003-09-25       Impact factor: 21.405

2.  Biomarkers of airway acidity and oxidative stress in exhaled breath condensate from grain workers.

Authors:  Ron Do; Karen H Bartlett; Helen Dimich-Ward; Winnie Chu; Susan M Kennedy
Journal:  Am J Respir Crit Care Med       Date:  2008-08-21       Impact factor: 21.405

3.  Increased 8-isoprostane, a marker of oxidative stress, in exhaled condensate of asthma patients.

Authors:  P Montuschi; M Corradi; G Ciabattoni; J Nightingale; S A Kharitonov; P J Barnes
Journal:  Am J Respir Crit Care Med       Date:  1999-07       Impact factor: 21.405

4.  GC-MS determination of ratios of stable-isotope labelled to natural urea using [13C15N2]urea for studying urea kinetics in serum and as a means to validate routine methods for the quantitative assay of urea in dialysate.

Authors:  B G Wolthers; T Tepper; A Withag; G T Nagel; T H de Haan; J J van Leeuwen; C A Stegeman; R M Huisman
Journal:  Clin Chim Acta       Date:  1994-02       Impact factor: 3.786

5.  Determination of serum urea by isotope dilution mass spectrometry as a candidate definitive method.

Authors:  M J Welch; A Cohen; H S Hertz; F C Ruegg; R Schaffer; L T Sniegoski; E White
Journal:  Anal Chem       Date:  1984-04       Impact factor: 6.986

6.  Exhaled breath condensate purines correlate with lung function in infants and preschoolers.

Authors:  Kavita Patel; Stephanie D Davis; Robin Johnson; Charles R Esther
Journal:  Pediatr Pulmonol       Date:  2012-05-21

7.  Prevalence of childhood asthma in urban communities: the impact of ethnicity and income.

Authors:  Luz Claudio; Jeanette A Stingone; James Godbold
Journal:  Ann Epidemiol       Date:  2005-10-20       Impact factor: 3.797

8.  Measurement of urea in human serum by isotope dilution mass spectrometry: a reference procedure.

Authors:  A Kessler; L Siekmann
Journal:  Clin Chem       Date:  1999-09       Impact factor: 8.327

9.  Kinetics of urea exchange in air-filled and fluid-filled rat lungs.

Authors:  R M Effros; C Murphy; K Ozker; A Hacker
Journal:  Am J Physiol       Date:  1992-12

10.  Measurement of urea kinetics in humans: a validation of stable isotope tracer methods.

Authors:  D E Matthews; R S Downey
Journal:  Am J Physiol       Date:  1984-06
View more
  3 in total

1.  A colorimetric nanoprobe based on dynamic aggregation of SDS-capped silver nanoparticles for tobramycin determination in exhaled breath condensate.

Authors:  Homa Rezaei; Elaheh Rahimpour; Maryam Khoubnasabjafari; Vahid Jouyban-Gharamaleki; Abolghasem Jouyban
Journal:  Mikrochim Acta       Date:  2020-02-22       Impact factor: 5.833

2.  Specific Metabolome Profile of Exhaled Breath Condensate in Patients with Shock and Respiratory Failure: A Pilot Study.

Authors:  Brice Fermier; Hélène Blasco; Emmanuel Godat; Cinzia Bocca; Joseph Moënne-Loccoz; Patrick Emond; Christian R Andres; Marc Laffon; Martine Ferrandière
Journal:  Metabolites       Date:  2016-09-01

3.  Quantifying hormones in exhaled breath for physiological assessment of large whales at sea.

Authors:  Elizabeth A Burgess; Kathleen E Hunt; Scott D Kraus; Rosalind M Rolland
Journal:  Sci Rep       Date:  2018-07-17       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.