Literature DB >> 24187345

Tapered fluted modular titanium stems in the management of Vancouver B2 and B3 peri-prosthetic fractures.

J T Munro1, B A Masri, D S Garbuz, C P Duncan.   

Abstract

Tapered, fluted, modular, titanium stems are increasingly popular in the operative management of Vancouver B2 and selected B3 peri-prosthetic femoral fractures. We have reviewed the results at our institution looking at stem survival and clinical outcomes and compared this with reported outcomes in the literature. Stem survival at a mean of 54 months was 96% in our series and 97% for combined published cases. Review of radiology showed maintenance or improvement of bone stock in 89% of cases with high rates of femoral union. Favourable clinical outcome scores have reported by several authors. No difference in survival or clinical scores was observed between B2 and B3 fractures. Tapered stems are a useful option in revision for femoral fracture across the spectrum of femoral bone deficiency.

Entities:  

Keywords:  Peri-prosthetic fracture; Revision hip arthroplasty; Taper stem

Mesh:

Substances:

Year:  2013        PMID: 24187345     DOI: 10.1302/0301-620X.95B11.32898

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  6 in total

Review 1.  Periprosthetic femoral fracture - an interdisciplinary challenge.

Authors:  Alexander Hagel; Holger Siekmann; Karl-Stefan Delank
Journal:  Dtsch Arztebl Int       Date:  2014-09-26       Impact factor: 5.594

2.  Treatment of periprosthetic femoral fractures with modular stems.

Authors:  Daniel Hernandez-Vaquero; Jesus Fernandez-Lombardia; Jimena Llorens de los Rios; Ivan Perez-Coto; Susana Iglesias-Fernandez
Journal:  Int Orthop       Date:  2015-08-19       Impact factor: 3.075

3.  Nonmodular Tapered Fluted Titanium Stems Osseointegrate Reliably at Short Term in Revision THAs.

Authors:  Nemandra A Sandiford; Donald S Garbuz; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2016-09-26       Impact factor: 4.176

4.  Outcomes following revision surgery performed for adverse reactions to metal debris in non-metal-on-metal hip arthroplasty patients: Analysis of 185 revisions from the National Joint Registry for England and Wales.

Authors:  G S Matharu; A Judge; D W Murray; H G Pandit
Journal:  Bone Joint Res       Date:  2017-07       Impact factor: 5.853

5.  Medium Term Radiographic and Clinical Outcomes Using a Modular Tapered Hip Revision Implant.

Authors:  Gihan Jayasinghe; Chris Buckle; Lucy Clare Maling; Christopher To; Chukwudubem Anibueze; Parthiban Vinayakam; Richard Slack
Journal:  Arthroplast Today       Date:  2021-04-05

6.  Which factors influence the rate of failure following metal-on-metal hip arthroplasty revision surgery performed for adverse reactions to metal debris? an analysis from the National Joint Registry for England and Wales.

Authors:  G S Matharu; A Judge; H G Pandit; D W Murray
Journal:  Bone Joint J       Date:  2017-08       Impact factor: 5.082

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.