Literature DB >> 2418673

Balloon and blade atrial septostomy facilitated by two-dimensional echocardiography.

A E Lin, T G Di Sessa, R G Williams.   

Abstract

Two-dimensional echocardiography (2-D echo) was used as an imaging device for the performance of balloon atrial septostomy (n = 25) and blade atrial septostomy (n = 3). Biplane fluoroscopy with 2-D echo or 2-D echo alone were used in the cardiac catheterization laboratory to place the balloon or blade septostomy catheter in the left atrium. Echocardiography confirmed the position of the septostomy catheter before pullback. Balloon inflation and balloon or blade pullback to the right atrium was performed with 2-D echocardiographic visualization. In 8 critically ill newborn infants, balloon atrial septostomy was done in the neonatal intensive care unit without flouroscopy. The safety and efficacy of 2-D echo to assist balloon or blade atrial septostomy in the catheterization laboratory or as the sole imaging device in the neonatal intensive care unit are confirmed. Use of the subcostal 4-chamber and sagittal views to image cardiac anatomy and catheter position during the procedure are emphasized. Two-dimensional echo is particularly helpful in cases of cardiac malposition and during transseptal puncture of the atrial septum before blade septostomy, and lowers radiation dose when used in conjunction with fluoroscopy.

Entities:  

Mesh:

Year:  1986        PMID: 2418673     DOI: 10.1016/0002-9149(86)90904-5

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  5 in total

1.  Displacement of preexisting thrombus by umbilical vein catheterization.

Authors:  J S Chandar; S B Wolfe
Journal:  Pediatr Cardiol       Date:  1994 Nov-Dec       Impact factor: 1.655

2.  Echocardiographically guided balloon atrial septostomy during extracorporeal membrane oxygenation (ECMO).

Authors:  T A O'Connor; G J Downing; L L Ewing; R Gowdamarajan
Journal:  Pediatr Cardiol       Date:  1993-07       Impact factor: 1.655

3.  Congenital heart disease in the newborn requiring early intervention.

Authors:  Sin Weon Yun
Journal:  Korean J Pediatr       Date:  2011-05-31

4.  Balloon atrial septostomy under echocardiographic control: six years' experience and evaluation of the practicability of cannulation via the umbilical vein.

Authors:  M Ashfaq; A B Houston; J P Gnanapragasam; S Lilley; E P Murtagh
Journal:  Br Heart J       Date:  1991-03

Review 5.  Transposition of the great arteries.

Authors:  Paula Martins; Eduardo Castela
Journal:  Orphanet J Rare Dis       Date:  2008-10-13       Impact factor: 4.123

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.