Literature DB >> 24184957

Comparative label-free monitoring of immunotoxin efficacy in 2D and 3D mamma carcinoma in vitro models by impedance spectroscopy.

Sarah Poenick1, Heinz-Georg Jahnke, Marie Eichler, Stefan Frost, Hauke Lilie, Andrea A Robitzki.   

Abstract

For selective killing of tumor cells, there are many novel and promising therapeutic approaches like immunotoxins. However, on the long way to clinical application, especially in vitro approved biologicals often fail due to loss of target sensitivity and efficacy in vivo. This is mostly explained with degradation or penetration disability in vivo. Although, these problems are well known, until today, there are no in vitro systems for reliable monitoring and quantification of therapeutic efficacy in 3D tumor models and the direct comparison to results from 2D models. In this context, we developed a combined label-free impedimetric monitoring system using our self-developed planar interdigital electrode arrays and our unique microcavity array technology. Therefore, we could demonstrate the time and concentration dependent monitoring and quantification of therapeutic efficacy in a 2D and 3D mamma carcinoma model. In detail, we synthesized a novel modular immunotoxin B3(dsFv)-PE38 (B3-PE38) in which the antibody fragment and the protein toxin are polyionic linked together. We compared the efficacy of the immunotoxin B3-PE38, the toxin E8C-PE38 (PE38) and the small molecule chemotherapeutic paclitaxel. The impedimetric screening revealed the highest cytotoxicity for the immunotoxin B3-PE38 in the 2D model. More strikingly, the immunotoxin efficacy was substantially higher in the 3D model when compared to PE38 and paclitaxel even though having a considerably lower penetration capability than paclitaxel. So our novel impedimetric monitoring system offers the comparative efficacy quantification of novel therapeutics in 2D and 3D in vitro tumor models.
© 2013 Published by Elsevier B.V.

Entities:  

Keywords:  3D tumor model; Immunotoxins; Impedance spectroscopy; Interdigital electrode array; Microcavity array

Mesh:

Substances:

Year:  2013        PMID: 24184957     DOI: 10.1016/j.bios.2013.09.048

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

Review 1.  Chip based single cell analysis for nanotoxicity assessment.

Authors:  Pratikkumar Shah; Ajeet Kaushik; Xuena Zhu; Chengxiao Zhang; Chen-Zhong Li
Journal:  Analyst       Date:  2014-05-07       Impact factor: 4.616

2.  Automated, Multiplexed Electrical Impedance Spectroscopy Platform for Continuous Monitoring of Microtissue Spheroids.

Authors:  Sebastian C Bürgel; Laurin Diener; Olivier Frey; Jin-Young Kim; Andreas Hierlemann
Journal:  Anal Chem       Date:  2016-10-27       Impact factor: 6.986

3.  Parallelized Wireless Sensing System for Continuous Monitoring of Microtissue Spheroids.

Authors:  Lei Dong; Paolo S Ravaynia; Qing-An Huang; Andreas Hierlemann; Mario M Modena
Journal:  ACS Sens       Date:  2020-06-26       Impact factor: 7.711

4.  Iterative Precise Conductivity Measurement with IDEs.

Authors:  Jaromír Hubálek
Journal:  Sensors (Basel)       Date:  2015-05-22       Impact factor: 3.576

5.  Induced cross-resistance of BRAFV600E melanoma cells to standard chemotherapeutic dacarbazine after chronic PLX4032 treatment.

Authors:  Sarah Erdmann; Diana Seidel; Heinz-Georg Jahnke; Marie Eichler; Jan-Christoph Simon; Andrea A Robitzki
Journal:  Sci Rep       Date:  2019-01-10       Impact factor: 4.379

6.  Electrochemical live monitoring of tumor cell migration out of micro-tumors on an innovative multiwell high-dense microelectrode array.

Authors:  Heinz-Georg Jahnke; Agneta Mewes; Franziska D Zitzmann; Sabine Schmidt; Ronny Azendorf; Andrea A Robitzki
Journal:  Sci Rep       Date:  2019-09-25       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.