Numerical identification method for the non-linear viscoelastic compressible behavior of soft tissue using uniaxial tensile tests and image registration - application to rat lung parenchyma.

A Bel-Brunon1, S Kehl, C Martin, S Uhlig, W A Wall.   

Abstract

This paper presents an improved identification method of the constitutive properties of lung parenchyma. We aim to determine the non-linear viscoelastic behavior of lung parenchyma with a particular focus on the compressible properties - i.e. the ability to change volume. Uniaxial tensile tests are performed on living precision-cut rat lung slices. Image registration is used to compute the displacement field at the surface of the sample. The constitutive model consists of a hyperelastic potential split into volumetric and isochoric contributions and a viscous contribution. This allows for the description of the experimentally observed hysteresis loop. The identification is performed numerically: each test is simulated using the realistic geometry of the sample; the difference between the measured and computed displacements is minimized with an optimization algorithm. We compare several hyperelastic potentials and we can determine the most suitable law for rat lung parenchyma. An exponential potential or a polynomial potential with a first order term and a third or higher order term give similarly satisfactory results. The identified parameters are: for the volumetric contribution: κ=7.25e4Pa, for the exponential form: k1=4.34e3Pa, k2=5.92, for the polynomial form: C1=2.87e3Pa, C3=3.83e4Pa. The identification of the time parameter for the viscous contribution shows that it depends on the loading frequency (0.2Hz: τ=0.257s, 0.4Hz: τ=0.123s, 0.8Hz: τ=0.050s). Adding a viscous contribution significantly increases the accuracy of the identification.
© 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Compressibility; Image registration; Lung parenchyma; Non-linear viscoelasticity; Numerical identification; Uniaxial tensile test

Mesh:

Year:  2013        PMID: 24184860     DOI: 10.1016/j.jmbbm.2013.09.018

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  5 in total

Review 1.  Computational lung modelling in respiratory medicine.

Authors:  Sunder Neelakantan; Yi Xin; Donald P Gaver; Maurizio Cereda; Rahim Rizi; Bradford J Smith; Reza Avazmohammadi
Journal:  J R Soc Interface       Date:  2022-06-08       Impact factor: 4.293

2.  On the behaviour of lung tissue under tension and compression.

Authors:  Pinelopi Andrikakou; Karthik Vickraman; Hari Arora
Journal:  Sci Rep       Date:  2016-11-07       Impact factor: 4.379

3.  Cervical Rotatory Manipulation Decreases Uniaxial Tensile Properties of Rabbit Atherosclerotic Internal Carotid Artery.

Authors:  Shaoqun Zhang; Ji Qi; Lei Zhang; Chao Chen; Shubhro Mondal; Kaike Ping; Yili Chen; Yikai Li
Journal:  Evid Based Complement Alternat Med       Date:  2017-02-16       Impact factor: 2.629

4.  Automatic mapping of atrial fiber orientations for patient-specific modeling of cardiac electromechanics using image registration.

Authors:  Julia M Hoermann; Martin R Pfaller; Linda Avena; Cristóbal Bertoglio; Wolfgang A Wall
Journal:  Int J Numer Method Biomed Eng       Date:  2019-03-14       Impact factor: 2.747

5.  Whole-lung finite-element models for mechanical ventilation and respiratory research applications.

Authors:  Nibaldo Avilés-Rojas; Daniel E Hurtado
Journal:  Front Physiol       Date:  2022-10-04       Impact factor: 4.755