Literature DB >> 24183564

Third-generation zotarolimus-eluting and everolimus-eluting stents in all-comer patients requiring a percutaneous coronary intervention (DUTCH PEERS): a randomised, single-blind, multicentre, non-inferiority trial.

Clemens von Birgelen1, Hanim Sen2, Ming Kai Lam2, Peter W Danse3, Gillian A J Jessurun4, Raymond W M Hautvast5, Gert K van Houwelingen2, Alexander R Schramm4, R Melvyn Tjon Joe Gin3, Johannes W Louwerenburg2, Frits H A F de Man2, Martin G Stoel2, Marije M Löwik2, Gerard C M Linssen6, Salah A M Saïd6, Mark B Nienhuis7, Patrick M J Verhorst2, Mounir W Z Basalus2, Carine J M Doggen8, Kenneth Tandjung2.   

Abstract

BACKGROUND: Third-generation, permanent-polymer-based drug-eluting stents with novel, flexible designs might be more easily delivered than previous generations of stents in complex coronary lesions, but might be less longitudinally stable. We aimed to assess the safety and efficacy in all-comer patients of two third-generation stents that are often used clinically, but that have not yet been compared, and one of which has not previously been assessed in a randomised trial.
METHODS: In this investigator-initiated, single-blind, multicentre, randomised, two-arm, non-inferiority trial, patients aged 18 years and older who required a percutaneous coronary intervention with implantation of a drug-eluting stent were recruited from four study sites in the Netherlands. We randomly assigned patients by independently managed computer-generated allocation sequences in a 1:1 ratio to receive either cobalt-chromium-based zotarolimus-eluting stents (Resolute Integrity, Medtronic, Santa Rosa, CA, USA) or platinum-chromium-based everolimus-eluting stents (Promus Element, Boston Scientific, Natick, MA, USA). Patients and analysts were masked to the allocated stent, but treating clinicians were not. The primary endpoint of target-vessel failure was a composite of safety (cardiac death or target-vessel-related myocardial infarction) and efficacy (target-vessel revascularisation) at 12 months, analysed by intention to treat (with a non-inferiority margin of 3·6%). This trial is registered with ClinicalTrials.gov, number NCT01331707.
FINDINGS: Between Nov 25, 2010, and May 24, 2012, 1811 eligible all-comer patients, with 2371 target lesions, were enrolled in the study. 370 (20%) patients presented with ST-elevation myocardial infarction and 447 (25%) with non-ST-elevation myocardial infarction. 906 patients were assigned to receive zotarolimus-eluting stents and 905 to receive everolimus-eluting stents. Ease of stent delivery was shown by very low numbers of patients requiring treatment other than their assigned study treatment (six [1%] in the zotarolimus-eluting stent group vs five [1%] in the everolimus-eluting stent group; p=0·22). 12-month follow-up results were available for 1810 patients (one patient in the zotarolimus-eluting stent group withdrew consent). The primary endpoint was met by 55 (6%) of 905 patients in the zotarolimus-eluting stent group and 47 (5%) of 905 in the everolimus-eluting stent group. The zotarolimus-eluting stent was non-inferior to the everolimus-eluting stent (absolute risk difference 0·88%, 95% CI -1·24% to 3·01%; upper limit of one-sided 95% CI 2·69%; non-inferiority p=0·006). We noted no significant between-group differences in individual components of the primary endpoint. Definite stent thrombosis occurred in three (0·3%) patients in the zotarolimus-eluting stent group and six (0·7%) patients in the everolimus-eluting stent group (p=0·34). Longitudinal stent deformation was seen only in the everolimus-eluting stent group (nine [1·0%] of 905 vs 0 of 906, p=0·002; nine of 1591 [0·6%] everolimus-eluting stents implanted became deformed), but was not associated with any adverse events.
INTERPRETATION: Both stents were similarly efficacious and safe, and provided excellent clinical outcomes, especially in view of the large number of patients who presented with acute myocardial infarctions. FUNDING: Boston Scientific, Medtronic.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24183564     DOI: 10.1016/S0140-6736(13)62037-1

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  32 in total

1.  Stent fracture and longitudinal compression detected on coronary CT angiography in the first- and new-generation drug-eluting stents.

Authors:  Mi Sun Chung; Dong Hyun Yang; Young-Hak Kim; Jae-Hyung Roh; Jihyun Song; Joon-Won Kang; Jung-Min Ahn; Duk-Woo Park; Soo-Jin Kang; Seung-Whan Lee; Cheol Whan Lee; Seong-Wook Park; Seung-Jung Park; Tae-Hwan Lim
Journal:  Int J Cardiovasc Imaging       Date:  2015-10-26       Impact factor: 2.357

2.  Incidence and predictors of target lesion failure in patients undergoing contemporary DES implantation-Individual patient data pooled analysis from 6 randomized controlled trials.

Authors:  Maayan Konigstein; Mahesh V Madhavan; Ori Ben-Yehuda; Hussein M Rahim; Iva Srdanovic; Fotis Gkargkoulas; Ghazaleh Mehdipoor; Evan Shlofmitz; Akiko Maehara; Björn Redfors; Ankita K Gore; Thomas McAndrew; Gregg W Stone; Ziad A Ali
Journal:  Am Heart J       Date:  2019-04-12       Impact factor: 4.749

Review 3.  The development of carotid stent material.

Authors:  Dongsheng He; Wenhua Liu; Tao Zhang
Journal:  Interv Neurol       Date:  2015-03

Review 4.  Drug-eluting stents: the past, present, and future.

Authors:  Gregory Katz; Bhisham Harchandani; Binita Shah
Journal:  Curr Atheroscler Rep       Date:  2015-03       Impact factor: 5.113

5.  Bare Metal Stents Versus Drug Eluting Stents: Where Do We Stand in 2015?

Authors:  Perwaiz M Meraj; Rajiv Jauhar; Avneet Singh
Journal:  Curr Treat Options Cardiovasc Med       Date:  2015-08

Review 6.  Use of Mortality as an Endpoint in Noninferiority Trials May Lead to Ethically Problematic Conclusions.

Authors:  Andrew M Hersh; Robert J Walter; Scott K Abberegg
Journal:  J Gen Intern Med       Date:  2019-02-12       Impact factor: 5.128

7.  Delivery of drugs, growth factors, genes and stem cells via intrapericardial, epicardial and intramyocardial routes for sustained local targeted therapy of myocardial disease.

Authors:  M G Katz; A S Fargnoli; R J Hajjar; C R Bridges
Journal:  Expert Opin Drug Deliv       Date:  2017-06-22       Impact factor: 6.648

Review 8.  Technological Advances in Stent Therapies: a Year in Review.

Authors:  Jad Raffoul; Ammar Nasir; Andrew J P Klein
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-04-07

9.  Response to the letter to the editor: delivery of drugs, growth factors, genes and stem cells via intrapericardial, epicardial and intramyocardial routes for sustained local targeted therapy of myocardial disease.

Authors:  M Maslov; S Foianini; M Lovich
Journal:  Expert Opin Drug Deliv       Date:  2017-07       Impact factor: 6.648

10.  Long-Term Safety and Efficacy of Platinum Chromium Everolimus-Eluting Stents in Coronary Artery Disease: 5-Year Results From the PLATINUM Trial.

Authors:  Christopher R Kelly; Paul S Teirstein; Ian T Meredith; Bruno Farah; Christophe L Dubois; Robert L Feldman; Joseph Dens; Nobuhisa Hagiwara; Abram Rabinowitz; Didier Carrié; Vincent Pompili; Alain Bouchard; Shigeru Saito; Dominic J Allocco; Keith D Dawkins; Gregg W Stone
Journal:  JACC Cardiovasc Interv       Date:  2017-12-11       Impact factor: 11.195

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.